1 von 1

Mitsubishi Electric FR-A840-01800-2-60 FR-A800 Series Inverter

Mitsubishi Electric FR-A840-01800-2-60 FR-A800 Series Inverter

Nur noch 10 Artikel auf Lager verfügbar
  • Hersteller: Mitsubishi Electric

  • Produkt-Nr.: FR-A840-01800-2-60

  • Herkunftsland:Vereinigte Staaten

  • Produkttyp: Variable Frequency Drives

  • Zahlung: T/T, Western Union

  • Gewicht: 48000g

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Anzahl
Vollständige Details anzeigen

Description

Engineered to deliver precise speed and torque control in demanding heavy-duty environments, the Mitsubishi Electric FR-A840-01800-2-60 is a high-performance variable frequency drive belonging to the flagship FR-A800 series. Featuring a 400V class design, this standard model supports multi-rating operations, peaking at a Super Light Duty (SLD) rated inverter current of 180A. The integration of 3C2 circuit board conformal coating guarantees high operational reliability by protecting sensitive electronics from corrosive gases and moisture, making this robust 48 Kg unit ideal for critical infrastructure and manufacturing environments.

Features

  • Multi-Rating Architecture: Optimizes power matching by offering four distinct duty ratings (SLD, LD, ND, HD) to fit specific industrial load requirements.
  • Conformal Circuit Board Coating: Complies with IEC 60721-3-3 Class 3C2 specifications, shielding inner electronics from industrial pollutants.
  • Real Sensorless Vector Control (RSV): Offers dynamic speed and torque control without requiring external encoder feedback.
  • Comprehensive Safety Functions: Built-in dual-channel emergency stop circuit complying with EN ISO 13849-1 Category 3/PLd and IEC 60204-1.
  • Advanced Energy Saving: Employs optimum excitation control to minimize motor power consumption under variable loads.

Applications

  • High-capacity water pump facilities and ventilation fans.
  • Heavy material handling, cranes, and gantry hoist units.
  • Extrusion lines, mixers, and industrial centrifuges.
  • Complex conveyor systems requiring precise speed synchronization.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model Code FR-A840-01800-2-60
Inverter Series FR-A800
Voltage Class 400V class (3-Phase 380V to 500V AC, 50/60 Hz)
Super Light Duty (SLD) Current 180 A
Light Duty (LD) Current 144 A
Normal Duty (ND) Current 115 A
Heavy Duty (HD) Current 96 A
Circuit Board Coating Complying with IEC 60721-3-3 3C2 (With Coating)
Plated Conductor Without
Enclosure Rating IP00 (Open Type)
Cooling Method Forced Air Cooling
Shipping Weight (Actual) 48.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

When upgrading older FR-A740 legacy series installations to the FR-A840-01800-2-60, ensure the physical depth clearance is double-checked as the A800 series chassis footprint varies slightly due to updated cooling duct paths. The "-2-60" configuration denotes specific control terminal variants standard in CA markets. Use the Mitsubishi FR Configurator2 software to automatically map parameter registers from the old unit, reducing physical tuning down-time.

Application Pitfalls & Engineering Notes

Operating the VFD under the 180A SLD (Super Light Duty) profile is ideal for low-starting-torque installations like centrifugal fans. However, this configuration limits the overload limit to 110% for 60 seconds. Attempting to run high-inertia loads (like positive displacement pumps or crushers) on the SLD rating can trigger intermittent overcurrent trips (E.OC1 or E.OC2). For high-torque applications, the drive must be programmed and wired under the Normal Duty (115A / 150% overload) or Heavy Duty (96A / 200% overload) profiles.

Commissioning & Wiring Tips

Because this VFD lacks standard internal plated conductors, ensure all high-power terminal connections are torqued precisely to the OEM specifications in the manual to prevent oxidation or terminal overheating. Use symmetrical shielded motor cables (3-phase + ground) and establish a solid 360-degree ground contact on the metal cable gland plate to minimize high-frequency electromagnetic noise emitting to nearby analog instrumentation lines.

Installation Guidelines

CRITICAL WARNING: Hazardous voltage levels exist inside the enclosure. Isolate and lock out all AC main incoming feeds. Wait at least 10 minutes following complete power isolation to allow internal DC bus capacitors to discharge. Verify terminal DC-to-ground potential is 0V with an approved meter before initiating wiring or physical interventions.
  1. 1 Install the heavy 48 kg drive vertically on a flat, non-combustible steel panel. Maintain a minimum cooling clearance of 100 mm above and below the unit, and 50 mm horizontally from adjacent hardware to ensure uninhibited airflow.
  2. 2 Connect the incoming three-phase AC power lines to R/L1, S/L2, and T/L3. Ensure phase rotation matches local site code standards.
  3. 3 Route shielded motor wiring directly to output terminals U, V, and W. Do not connect AC mains power to these output terminals, as doing so will permanently destroy the IGBT modules.
  4. 4 Establish a solid low-impedance ground by landing the system ground conductor directly on the VFD PE grounding terminal.
  5. 5 Turn on power and configure fundamental parameters (Pr. 1 to Pr. 9) matching the motor nameplate. Execute an offline motor auto-tuning run to optimize vector control algorithms.
Loading product navigation…

What is the primary difference between the SLD and HD ratings for this inverter?

This drive features multi-rating architecture. Super Light Duty (SLD) supports up to 180A output current with 110% overload for 60 seconds. Heavy Duty (HD) limits current to 96A but permits up to 200% overload for 60 seconds, which is crucial for high-inertia industrial loads.

What protection does the 3C2 circuit board coating provide?

The conformal board coating meets IEC 60721-3-3 Class 3C2 standards, protecting internal electronics from environmental degradation caused by chemical vapor, humidity, and conductive atmospheric dust.

Can this drive run permanent magnet (PM) motors?

Yes, the FR-A800 series natively supports both standard induction motors and permanent magnet motors, configured easily during commissioning utilizing the auto-tuning parameters.

Does the FR-A840-01800-2-60 include an integrated dynamic braking resistor?

No, given the 180A output capacity, high-inertia regenerative braking requires an external brake unit (such as the FR-BU2) paired with dedicated external braking resistors.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage per DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) eingehen.
  • Weltweite Abdeckung: Wir beliefern über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden von Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabebedingungen lesen Sie bitte unsere offiziellen Rückerstattungs- & Rückgaberecht .

TECHNICAL SPECIFICATIONS

Country of origin
Vereinigte Staaten

Kürzlich angesehene Produkte

Technisches Wissen

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Die boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...

Factory I/O: Ein modernes PLC-Simulationswerkzeug für die Ausbildung in der Industrieautomatisierung

Factory I/O revolutioniert die SPS-Ausbildung, indem es immersive 3D-Industriesimulationen für Studenten, Ingenieure und Wartungsteams bereitstellt. Die Plattform überbrückt die Lücke zwischen...