Direct human-machine interface interaction is established through the Omron NS5-MQ11-V2, a reliable monochrome terminal engineered for integration within the Omron NS Series architecture. This unit provides a highly functional visual interface for machine-level monitoring and control, housing a robust display in a durable panel-mount form factor. Configured with dual RS-232C ports, it coordinates seamless communication with host PLCs, temperature controllers, and auxiliary devices. Designed for operational longevity, this model features an ivory bezel that integrates cleanly with classic industrial control cabinets.

Features

  • Monochrome STN Display: Offers clear legibility for alarms, status registers, and process variables at a standard 320 x 240 pixel resolution.
  • Dual Serial Connectivity: Features two independent RS-232C interfaces for multi-device or dual-protocol configurations.
  • Dedicated Programming Interface: Integrated USB slave port allows high-speed screen data transfer and debugging directly from CX-Designer.
  • Memory Expansion Slot: Rear-accessible slot supports standard CompactFlash cards for backup, data logging, and system firmware updates.
  • High-Durability Bezel: IP65F front-panel rating provides robust protection against ingress of moisture and fine particulate matter in harsh environments.

Applications

  • Packaging Machinery: Local machine control panels requiring fast screens, recipe modification, and alarm status tracking.
  • Material Handling: Monitoring conveyor speeds, diverter status, and sorting criteria on localized nodes.
  • Process Subsystems: Interface terminal for localized water treatment, environmental chambers, or basic raw material dosing units.

Technical Specifications

Manufacturer Omron
Model Reference NS5-MQ11-V2
Series NS Series
Display Type STN Monochrome LCD
Display Size 5.7 inches
Resolution 320 x 240 pixels (QVGA)
Input Voltage 24 VDC (Acceptable range: 20.4 to 27.6 VDC)
Power Consumption 15 Watts maximum
Serial Communications 2x RS-232C Ports
USB Ports 1x USB Type-B Slave (USB 1.1)
Case Color Ivory
Operating Temperature 0 to 50 degC
Front Panel Protection IP65F equivalent
Country of Origin Japan
Shipping Weight (Calculated) 1.5 kg
Package Dimensions (Calculated) 24.5 cm x 19.2 cm x 8.5 cm

Connections and Interfaces

Port Reference Connector Type Functional Assignment / Signal Mapping
Serial Port A D-Sub 9-pin Female Host Link / NT Link RS-232C serial connection to PLC CPU.
Serial Port B D-Sub 9-pin Female Auxiliary serial communications (RS-232C), peripheral devices, or temperature controllers.
USB Tool Port USB Type-B (Slave) Dedicated interface for high-speed programming, screen downloads, and online system debugging.
Power Input Terminal M3.5 Screw Terminal Block 24 VDC Power Input along with functional ground (FG) terminal for noise abatement.

Empirical Engineering Insights

Alternative Models & Compatibility

The "V2" suffix represents upgraded internal processing and expanded compatibility with newer runtime versions compared to legacy V1 variants. Note that the NS5-MQ11-V2 (Ivory bezel) is chemically and structurally identical in internal operation to the NS5-MQ11B-V2 (Black bezel), permitting direct drop-in substitution when bezel aesthetics are not critical. Software configuration projects built in CX-Designer can target either color variant without modification.

Application Pitfalls & Engineering Notes

Because this unit utilizes a monochrome STN LCD, viewing angles and response latency can be more pronounced compared to modern TFT equivalents. When designing HMI screens, maintain high-contrast graphic layouts (solid black/white configurations rather than gradient shades) to preserve visibility in direct plant floor lighting. Ensure the rear ventilation slot is unblocked; operation inside enclosures exceeding 50 degC will significantly accelerate CCFL backlight degradation.

Commissioning & Wiring Tips

To protect against communication time-outs and localized ground loop disruption, dedicated 24 VDC supply routing is recommended. Keep serial RS-232C lines isolated from high-voltage motor starters and variable frequency drive cables. Always verify the functional ground terminal is tied back to a solid low-impedance earth connection using a wire size of at least 2.0 mm².

Installation Guidelines

CRITICAL WARNING

Isolate and verify de-energization of the primary power supply source before working on the 24 VDC terminals. Do not service the power connector, change the system configuration, or adjust wiring while voltage is applied to avoid physical shock or severe control system damage.

1 Ensure the panel cutout dimensions conform exactly to the physical specs of 184 mm x 131 mm.
2 Seat the waterproofing gasket completely around the inner bezel lip before inserting the unit into the cutout.
3 Tighten the included mounting brackets evenly to a torque of 0.5 to 0.6 N-m to achieve a proper IP65F seal without cracking the bezel.
4 Terminate the 24 VDC power lines using insulated crimp terminals on the M3.5 screws. Ensure polarity is strictly maintained.
Loading product navigation…

What is the structural difference between the NS5-MQ11-V2 and the NS5-MQ11B-V2?

The only difference is the physical enclosure color. The NS5-MQ11-V2 has an ivory-colored front bezel, whereas the NS5-MQ11B-V2 has a black bezel. Internally, all electrical specifications, software requirements, and communications are identical.

Can I program the NS5-MQ11-V2 via an Ethernet connection?

No, the NS5-MQ11-V2 is a serial-only base terminal. Screen transfer and firmware operations must be performed using either the dedicated USB slave port connected directly to a PC running CX-Designer, or via a formatted CompactFlash card in the expansion slot.

Does this model support direct NT Link communications?

Yes. Both integrated serial ports support high-speed 1:1 and 1:N NT Link protocols, alongside Host Link, for seamless data exchange with compatible Omron Sysmac PLCs.

What software is used to design and download screens for this HMI?

The Omron NS5-MQ11-V2 is configured using the CX-Designer software, which is part of the comprehensive CX-One software suite. It is highly recommended to use CX-Designer version 3.0 or higher.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...