Description

Designed for seamless integration within high-speed Sysmac automation platforms, the NX-OD5256-1 serves as a high-density digital output module featuring 16 transistor outputs. This unit enables precise control over field actuators by delivering reliable switching performance synchronized with the machine controller's execution cycle. Operating on a 24 VDC rated voltage, the module utilizes PNP (source) logic and features built-in load short-circuit protection to safeguard system electronics against field-side electrical faults.

The unit supports advanced synchronization capabilities, allowing for both Free-Run and Synchronous I/O refreshing. Field connections are secured via a rugged, detachable M3 screw terminal block, which facilitates easy installation and maintenance. Designed for mounting on a standard DIN rail, this module connects directly to NX-series Bus Couplers for EtherCAT or EtherNet/IP, making it highly compatible with modern distributed control architectures.

Features

  • Provides 16 digital output points in a compact form factor.
  • Utilizes PNP (source) output logic with a rated voltage of 24 VDC.
  • Features integrated load short-circuit protection for system safety.
  • Supports Synchronous I/O refreshing and Free-Run refreshing modes.
  • Equipped with a detachable M3 screw terminal block for reliable physical wiring.
  • Simplifies configuration and troubleshooting via Sysmac Studio software.

Applications

  • Packaging and labeling machinery control
  • Automated assembly and material handling systems
  • Water treatment and environmental control panels
  • Pneumatic and hydraulic valve manifold actuation
  • General factory automation and distributed I/O systems

Technical Specifications

Parameter Specification
Manufacturer Omron
Part Number/Model NX-OD5256-1
Series NX-series Digital I/O Unit
Output Type Transistor Output (PNP/Source)
Number of Outputs 16 points
Rated Voltage 24 VDC
Maximum Load Current 0.5 A per point
I/O Refreshing Method Free-Run refreshing, Synchronous I/O refreshing
Short-Circuit Protection Yes (Load short-circuit protection)
External Connection Terminals M3 screw terminal block
Dimensions (W x H x D) 30 mm x 100 mm x 71 mm
Weight 0.125 kg

Installation Guidelines

Ensure the following engineering practices are observed during the installation of the module:

  • Mounting: Mount the module securely onto a 35 mm DIN rail inside a protective industrial enclosure. Verify the DIN rail is properly grounded.
  • Wiring: Turn off all power supplies before connecting or disconnecting the M3 screw terminal block to prevent electrical shock or equipment damage.
  • Heat Dissipation: Maintain recommended clearances above and below the NX-series unit stack to ensure natural convection cooling. Do not block the ventilation holes.
  • Shielding and Noise: Route DC control lines separate from high-voltage AC power lines to minimize electromagnetic interference.

Compliance and Certifications

  • CE Mark
  • UL Listed (cULus)
Loading product navigation…

What is the output logic type of the Omron NX-OD5256-1?

The NX-OD5256-1 uses PNP (source) transistor output logic.

What kind of terminal connection does this module use?

The module is equipped with a detachable M3 screw terminal block for secure field wiring.

Does the NX-OD5256-1 support synchronous refreshing?

Yes, it supports both Free-Run refreshing and Synchronous I/O refreshing depending on the NX-series coupler and controller configuration.

What is the maximum output current rating per point?

The maximum load current is 0.5 A per output point.

Does this digital output unit include protection circuits?

Yes, the unit features built-in load short-circuit protection to protect the internal circuitry from fault currents.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage via DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir bedienen über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails, sehen Sie bitte unsere offizielle Seite ein Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Kürzlich angesehene Produkte

Technisches Wissen

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie SPS-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...