1 von 1

ProSoft PLX31-EIP-MBS4 Serial Four-Port Communication Gateway

ProSoft PLX31-EIP-MBS4 Serial Four-Port Communication Gateway

Nur noch 10 Artikel auf Lager verfügbar
  • Hersteller: ProSoft

  • Produkt-Nr.: PLX31-EIP-MBS4

  • Herkunftsland:Vereinigte Staaten

  • Produkttyp: Communication Gateways

  • Zahlung: T/T, Western Union

  • Gewicht: 3000g

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Anzahl
Vollständige Details anzeigen

Description

The PLX31-EIP-MBS4 is an industrial-grade communication gateway designed to establish bi-directional data exchange between EtherNet/IP networks and Modbus Serial protocols. By acting as a protocol converter, this module permits EtherNet/IP-enabled controllers, such as Rockwell Automation Logix processors, to seamlessly read and write data to Modbus Serial devices. The gateway features four isolated serial ports, allowing independent configuration for RS-232, RS-422, or RS-485 electrical interfaces. This flexibility enables high-density integration of field instruments, power meters, drives, and flow controllers into modern control systems.

Engineered for demanding industrial environments, this interface module supports both EtherNet/IP Class 1 I/O connections for real-time control and Class 3 messaging for diagnostic data transfer. The dynamic data mapping capabilities allow engineers to optimize throughput, ensuring minimal latency between networks.

Features

  • Four fully independent, isolated serial ports supporting RS-232, RS-422, and RS-485 configurations.
  • Supports up to 5 EtherNet/IP Class 3 server connections and 8 Class 1 I/O connections.
  • Bi-directional data mapping between EtherNet/IP and Modbus Serial networks.
  • Configurable serial parameters including baud rate, parity, stop bits, and handshaking.
  • Diagnostics and monitoring available via web-based configuration tools.
  • Wide operating temperature range suited for unconditioned control cabinets.

Applications

  • SCADA and HMI integration with legacy Modbus field devices.
  • Power distribution networks integrating Modbus RTU power meters.
  • Oil and gas flow metering system communication.
  • Water and wastewater remote telemetry integration.
  • Industrial manufacturing assembly line automation.

Technical Specifications

ParameterSpecification
Manufacturer ProSoft Technology
Part Number / Model PLX31-EIP-MBS4
Product Type EtherNet/IP to Modbus Serial Gateway
Number of Serial Ports 4 (isolated)
Serial Interface Types RS-232, RS-422, RS-485
EtherNet/IP Class 3 Connections 5
EtherNet/IP Class 1 I/O Connections 8
I/O Connection Size 248 / 248 bytes
Max Requested Packet Interval (RPI) 5 ms per connection
Nominal Input Voltage 24 VDC
Allowed Input Voltage Range 10 to 36 VDC
Current Load (Nominal) 300 mA @ 24 VDC
Current Load (Maximum) 610 mA @ 10 to 36 VDC
Operating Temperature -25 degC to 70 degC
Storage Temperature -40 degC to 80 degC
Shipping Weight 3 kg

Connections and Interfaces

Interface PortPhysical Connection TypeSupported Protocols
Ethernet Port RJ45 (10/100 Mbps) EtherNet/IP, TCP/IP
Serial Port 1 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Serial Port 2 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Serial Port 3 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Serial Port 4 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Power Input 3-position terminal block Positive, Negative, GND

Installation Guidelines

  • Mounting: Install on standard 35mm DIN rails. Verify the locking mechanism is secure.
  • Grounding: Connect the dedicated ground terminal on the power connector directly to the panel functional ground using low-impedance copper wire.
  • Wiring: Route communication cabling (Ethernet and Serial) away from high-voltage AC lines to prevent electromagnetic interference.
  • Clearance: Maintain at least 50mm of clearance at the top and bottom of the module to support proper convective cooling.

Compliance and Certifications

  • CE Mark
  • UL/cUL Class I, Division 2
  • ATEX Zone 2
Loading product navigation…

What protocols does the ProSoft PLX31-EIP-MBS4 gateway bridge?

The PLX31-EIP-MBS4 bridges devices on an EtherNet/IP network with devices on Modbus Serial (RTU or ASCII) networks.

Can the serial ports be configured independently?

Yes, all four serial ports are isolated and can be individually configured for RS-232, RS-422, or RS-485 physical layer communication.

What are the power requirements for this gateway?

The module requires a nominal 24 VDC power supply, but supports an input range of 10 to 36 VDC.

How many Class 1 and Class 3 connections does it support?

It supports up to 5 Class 3 Server connections and up to 8 Class 1 I/O connections.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage per DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) eingehen.
  • Weltweite Abdeckung: Wir beliefern über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden von Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabebedingungen lesen Sie bitte unsere offiziellen Rückerstattungs- & Rückgaberecht .

TECHNICAL SPECIFICATIONS

Country of origin
Vereinigte Staaten

Kürzlich angesehene Produkte

Technisches Wissen

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere erweiterte Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Die boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Greifbacken hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...

Rückblick: Wie frühe Elektromotoren den Untertagebergbau veränderten

Von seilgetriebenen Gleichstromkompressoren bis hin zu batteriebetriebenen Grubenwagen markierten frühe Bergbauoperationen einen Wendepunkt in der industriellen Elektrifizierung. Dieser Artikel...

Factory I/O: Ein modernes PLC-Simulationswerkzeug für die Ausbildung in der Industrieautomatisierung

Factory I/O revolutioniert die SPS-Ausbildung, indem es immersive 3D-Industriesimulationen für Studenten, Ingenieure und Wartungsteams bereitstellt. Die Plattform überbrückt die Lücke zwischen...