1 von 1

Schneider Electric 170AAO92100 Modicon Momentum Analog Output Module

Schneider Electric 170AAO92100 Modicon Momentum Analog Output Module

Nur noch 6 Artikel auf Lager verfügbar
  • Hersteller: Schneider Electric

  • Produkt-Nr.: 170AAO92100

  • Herkunftsland:Frankreich

  • Produkttyp: Analog Output Modules

  • Zahlung: T/T, Western Union

  • Gewicht: 380g

  • Abmessungen: 26.0 x 18.0 x 5.5 cm

  • Versandhafen: Xiamen

  • Garantie: 12 Monate

Menge
Vollständige Details anzeigen

Description

Executing precise current loop control in distributed control architectures, the Schneider Electric 170AAO92100 serves as a high-reliability 4-channel analog output module within the Modicon Momentum series. This hardware component converts digital control signals from the processor or network adapter into 4-20 mA analog outputs, allowing seamless interface connection to control valves, variable speed drives, actuators, and analog indicators. Engineered for modular flexibility, this unit clips directly onto a Momentum communication adapter or processor base, reducing field wiring complexity and optimizing cabinet panel footprint.

Features

  • Four Independent Channels: Multi-channel output capabilities manage up to four distinct 4-20 mA field loops simultaneously.
  • Modular Architecture: Integrates directly with Modicon Momentum network adapters (including Modbus TCP, Modbus Plus, and PROFIBUS) or local processor adapters.
  • High Resolution Conversion: Accurate 12-bit digital-to-analog converter ensures fine-grained control over external analog field devices.
  • Hot-Swapping Capability: Supports field-level servicing without interrupting system-wide communications when combined with compatible bases.
  • Integrated Status Diagnostics: Front-panel LED indication simplifies hardware status validation and channel fault isolation during active commissioning.

Applications

  • Modulating Control Valves: Precise positioning of pneumatic and electrical valves in chemical and water treatment facilities.
  • VFD Speed Referencing: Dynamic control over variable frequency drive speeds in conveyor systems and pumping stations.
  • Remote Field Distribution: Standardized analog field signaling in decentralized I/O networks spanning large factory floors.
  • SCADA Integration: Local analog signal reconstruction for instrumentation displays and environmental recording systems.

Technical Specifications

Parameter Specification Value
Manufacturer Schneider Electric
Part Number / SKU 170AAO92100
Product Range Modicon Momentum
Module Type Distributed Analog Output Module
Number of Outputs 4 Channels
Output Range 4 to 20 mA
Resolution 12-bit
External Power Requirement 24 VDC (Loop Power)
Country of Origin France
Commodity Code 85381000
Shipping Weight (Calculated) 0.38 kg
Package Dimensions (Calculated) 26.0 x 18.0 x 5.5 cm

Empirical Engineering Insights

Alternative Models & Compatibility

This module functions as a direct drop-in replacement across legacy Momentum field bus architectures. When migrating older systems to modern Modicon M580 controllers via Ethernet adapters, confirm that the network adapter head module firmware supports the 12-bit diagnostic registers mapped by the 170AAO92100 to prevent system configuration mismatches during hardware assembly scans.

Application Pitfalls & Engineering Notes

A common point of failure in field installations is the loss of external 24 VDC loop power. While the internal logic of the module remains powered through the network base adapter (allowing bus communication to remain active), a failure of the external loop power supply drops outputs to 0 mA. This can cause downstream devices to interpret the loss of signal as a broken wire fault (below the 4 mA limit threshold).

Commissioning & Wiring Tips

Always route the 4-20 mA field cables away from high-voltage AC motor lines to prevent electromagnetic induction from distorting output values. Ensure that cable shielding is terminated strictly at the local panel single-point ground. Shield grounding at both ends should be avoided to eliminate ground loop current interferences.

Installation Guidelines

CRITICAL WARNING: De-energize all primary, secondary, and external loop power sources connected to the Momentum base before mounting or removing the module. Failure to fully isolate field-level power can cause internal circuit damage or generate unexpected physical actuator movement in online process hardware.
1
Align the rear locating pins of the 170AAO92100 with the corresponding mounting slots on the pre-installed Momentum terminal base or communication adapter.
2
Press the module firmly down until the side locking tabs fully engage, confirming a secure structural and electrical connection to the underlying unit.
3
Terminate the external 4-20 mA signal loops and the auxiliary 24 VDC power supply to the designated terminals, adhering to the torque specifications on the connection diagram.
4
Apply external 24 VDC power followed by backplane network power, and verify the physical LED indicator sequence to ensure error-free channel initialization.
Loading product navigation…

What is the primary function of the 170AAO92100 module?

It acts as a distributed 4-channel analog output module, converting internal digital signals from a Modicon Momentum control network into physical 4-20 mA current loops to control field hardware.

Does this module require an external power supply for the current loops?

Yes, an external 24 VDC power supply must be wired to the module to supply power to the individual 4-20 mA analog loops.

What network communication protocols are compatible with this module?

It is compatible with any standard Modicon Momentum communication adapter base, including Modbus TCP/IP, Modbus Plus, PROFIBUS DP, and INTERBUS.

What is the analog output resolution of each channel?

The module utilizes a high-accuracy 12-bit digital-to-analog converter (DAC) across its operational 4 to 20 mA range.

Globaler Expressversand

  • Standardlieferung: 4-6 Werktage per DHL, FedEx und UPS.
  • Expressversand: Versand am selben Tag für vorrätige Bestellungen, die vor 14:00 Uhr (GMT+8) aufgegeben werden.
  • Weltweite Abdeckung: Wir beliefern über 150 Länder, einschließlich schneller Lieferung nach Saudi-Arabien und in die VAE.

Rückgaben & Garantie

  • 30-Tage-Garantie: Rückgaben werden für vorrätige Produkte in originaler, werkversiegelter Verpackung akzeptiert.
  • 12-Monats-Garantie: Jede Industriekomponente ist durch unsere professionelle technische Garantie abgesichert.

Bestellungen werden von Montag bis Freitag bearbeitet und geliefert (außer an Feiertagen).


Für vollständige Anspruchsvoraussetzungen, Wiedereinlagerungsgebühren und internationale Rückgabedetails sehen Sie bitte unsere offiziellen Rückerstattungs- & Rückgabebedingungen .

TECHNICAL SPECIFICATIONS

Country of origin
Frankreich

Kürzlich angesehene Produkte

Technisches Wissen

Elektrische Antriebe zur Ablösung von Fluidkraftsystemen: Ein praktischer Leitfaden für die industrielle Automatisierung

Dieser Artikel erklärt, wie integrierte elektrische Antriebe, wie die e-Actuator-Serie von SMC, die industrielle Bewegungssteuerung revolutionieren, indem sie herkömmliche pneumatische und...

Mathematische Operationen mit OpenPLC für industrielle Automatisierungsanwendungen

Dieser Artikel erklärt, wie SPS-Systeme grundlegende mathematische Operationen wie Addition, Subtraktion, Multiplikation, Division, Modulo und Exponentiation in der industriellen Automatisierung...

Fortgeschrittene Boolesche Logik mit FBD-SPS-Programmierung: Praktische industrielle Anwendungen über die Grundlogik hinaus

Der Artikel erklärt mehrere fortgeschrittene Boolesche Logikfunktionen, die in der SPS-Programmierung über die grundlegenden AND-, OR- und NOT-Operationen hinaus verwendet werden. Er behandelt, wie...

Boolesche Logik in der SPS-Programmierung: Verständnis von FBD-Logikgattern

Boolesche Logik ist die Grundlage jedes SPS-Programms. Von einfachen Maschinensteuerungen bis hin zu komplexen industriellen Automatisierungssystemen bestimmen Logikgatter, wie Steuerungen auf sich...

Umfassender Leitfaden zu industriellen Firewalls und OT-Netzwerksegmentierung

Industrielle Firewalls spielen eine entscheidende Rolle in der OT-Cybersicherheit, indem sie PLC-, DCS- und SCADA-Netzwerke durch Segmentierung, Ein- und Ausgangskontrolle sowie IDS/IPS-Integration...

Leitfaden für Roboter-Greifer: Von der schonenden Handhabung bis zur Schwerlastautomatisierung

Moderne robotische Greifer entwickeln sich über traditionelle mechanische Backen hinaus. Von gecko-inspirierten Haftsystemen und weichen, lebensmittelechten Greifern bis hin zu KI-gestützten...