900H02-0102 (900H02-0102) Honeywell ControlEdge HC900 Digital Output Module delivers 16-channel low side switching control for industrial automation systems. It operates with externally powered field loads and supports two isolated groups of eight outputs. Each group provides independent power terminals for stable distribution and fault separation. The module integrates intelligent power switching with built in electronic protection per channel. It serves continuous process industries such as oil refining, power generation, and chemical processing plants. Engineers deploy it to maintain reliable actuator control and reduce unplanned downtime in critical loops. Each channel includes LED status indication for real time diagnostics and fault visibility. The module supports fast response switching for high speed control applications. It also maintains stable operation under electrical stress and thermal variation. The design improves system uptime through automatic overload limitation and diagnostic reporting. It fits seamlessly into Honeywell HC900 ControlEdge architectures for scalable distributed control.
The module uses two isolated output banks to reduce fault propagation risk. Each bank supports eight current sinking outputs with shared field supply terminals. Intelligent power switches manage overload and temperature protection per channel. Internal diagnostics continuously monitor module health and output behavior. LED indicators provide direct visualization of channel activity and system status. The design ensures compatibility with standard DC industrial loads and actuators. It supports inductive and resistive loads within defined electrical limits. Backplane communication integrates with HC900 controller scan cycles for synchronized control execution.
| Parameter | Value |
|---|---|
| Model | 900H02-0102 |
| Brand | Honeywell |
| System Series | ControlEdge HC900 |
| Origin | USA |
| Weight | 2 kg |
| Output Channels | 16 (2 x 8 isolated groups) |
| Output Type | Current sinking, low side |
| Operating Voltage | 6.5 to 32 VDC |
| Peak Voltage | 34 VDC |
| ON Voltage Drop | 0.3 VDC at 1 A |
| Max Load Current | 1 A per point, 8 A per module |
| Leakage Current | 0.15 mA at 32 VDC |
| Inrush Current | 4 A for 10 ms |
| Response Time | 6 ms ON/OFF |
| Power Consumption | 5 VDC, 340 mA |
| Operating Temp | 0 to 60 deg C |
Is the 900H02-0102 compatible with all HC900 controllers?
It is fully compatible with Honeywell ControlEdge HC900 system architectures.
What happens during output overload conditions?
Each channel shuts down electronically and requires power cycle reset.
Can it drive inductive loads like solenoids?
Yes, within specified current and inductance limits up to 5 mH.
Does the module support redundancy?
It supports isolated groups but not full module redundancy by itself.
900H02-0102 (900H02-0102) Honeywell ControlEdge HC900 Digital Output Module delivers 16-channel low side switching control for industrial automation systems. It operates with externally powered field loads and supports two isolated groups of eight outputs. Each group provides independent power terminals for stable distribution and fault separation. The module integrates intelligent power switching with built in electronic protection per channel. It serves continuous process industries such as oil refining, power generation, and chemical processing plants. Engineers deploy it to maintain reliable actuator control and reduce unplanned downtime in critical loops. Each channel includes LED status indication for real time diagnostics and fault visibility. The module supports fast response switching for high speed control applications. It also maintains stable operation under electrical stress and thermal variation. The design improves system uptime through automatic overload limitation and diagnostic reporting. It fits seamlessly into Honeywell HC900 ControlEdge architectures for scalable distributed control.
The module uses two isolated output banks to reduce fault propagation risk. Each bank supports eight current sinking outputs with shared field supply terminals. Intelligent power switches manage overload and temperature protection per channel. Internal diagnostics continuously monitor module health and output behavior. LED indicators provide direct visualization of channel activity and system status. The design ensures compatibility with standard DC industrial loads and actuators. It supports inductive and resistive loads within defined electrical limits. Backplane communication integrates with HC900 controller scan cycles for synchronized control execution.
| Parameter | Value |
|---|---|
| Model | 900H02-0102 |
| Brand | Honeywell |
| System Series | ControlEdge HC900 |
| Origin | USA |
| Weight | 2 kg |
| Output Channels | 16 (2 x 8 isolated groups) |
| Output Type | Current sinking, low side |
| Operating Voltage | 6.5 to 32 VDC |
| Peak Voltage | 34 VDC |
| ON Voltage Drop | 0.3 VDC at 1 A |
| Max Load Current | 1 A per point, 8 A per module |
| Leakage Current | 0.15 mA at 32 VDC |
| Inrush Current | 4 A for 10 ms |
| Response Time | 6 ms ON/OFF |
| Power Consumption | 5 VDC, 340 mA |
| Operating Temp | 0 to 60 deg C |
Is the 900H02-0102 compatible with all HC900 controllers?
It is fully compatible with Honeywell ControlEdge HC900 system architectures.
What happens during output overload conditions?
Each channel shuts down electronically and requires power cycle reset.
Can it drive inductive loads like solenoids?
Yes, within specified current and inductance limits up to 5 mH.
Does the module support redundancy?
It supports isolated groups but not full module redundancy by itself.
Install the module in a grounded control cabinet to reduce electrical noise. Maintain proper separation between field wiring and signal wiring. Use shielded cables for inductive load circuits in high interference environments. Ensure torque tightening follows Honeywell cabinet wiring standards. Verify external power supply stability before commissioning. Avoid exceeding 8 A total module load to prevent thermal stress. In high vibration environments, secure terminal blocks with periodic inspection. Maintain airflow around racks to control internal temperature rise.
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Color pattern |
سیاه
|
| Country of origin |
ایالات متحده آمریکا
|
| Power source |
برق DC
|