BECKHOFF EL3413 EtherCAT Terminal: 3-Phase Power Measurement

BECKHOFF EL3413 EtherCAT Terminal: 3-Phase Power Measurement

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL3413

  • Country of origin:آلمان

  • Product Type: EtherCAT Terminal

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

The EL3413 is a high-precision, 3-phase EtherCAT Terminal designed for comprehensive power measurement of alternating voltages up to 690 V AC. It is engineered to monitor energy consumption and power quality directly within the EtherCAT system. With its ability to perform harmonic analysis and measure effective, reactive, and apparent power, the EL3413 is an essential component for energy management and grid monitoring applications.

Features

  • 3-Phase Power Measurement: Capable of monitoring 3-phase systems, with optional single-phase operation.
  • Extensive Measured Values: Provides data for current (I1, I2, I3, In), voltage, effective/reactive/apparent power, energy, cos φ, frequency, and harmonic analysis.
  • Galvanic Isolation: High electrical isolation (4500 V) and galvanically isolated current inputs ensure safety and measurement accuracy.
  • Flexible Current Input: Adjustable range for current measurement: 100 mA, 1 A (default), and 5 A.
  • Compact Design: 12 mm wide housing for high-density DIN rail mounting in control cabinets.

Applications

  • Industrial energy monitoring and cost optimization
  • Power quality analysis in electrical grids
  • Monitoring of machinery energy efficiency
  • Preventive maintenance for motor-driven systems

Technical Specifications

Category Specification
Manufacturer BECKHOFF
Model EL3413
Measuring Voltage Max. 690 V AC (3-phase)
Measuring Current Adjustable (100 mA, 1 A, 5 A)
Electrical Isolation 4500 V
Resolution 1 μA, 0.1 mV, 10 mW
Measuring Error 0.5 % (U/I), 1 % (calculated values)
Current Consumption (E-bus) typ. 160 mA
Operating Temperature -25 to +60 degC
Protection Rating IP20
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm

Installation Guidelines

  • Mount on a 35 mm DIN rail (EN 60715) using the integrated lock mechanism.
  • Ensure proper wiring for 3-phase voltage and current inputs, utilizing the spring-actuated terminals for solid or flexible conductors (stripping length 8–9 mm).
  • Adhere to all local electrical safety regulations when connecting high-voltage (up to 690 V AC) circuits.
  • Follow EMC immunity standards (EN 61000-6-2/EN 61000-6-4) for cabinet wiring to prevent electromagnetic interference with power data.
  • Ensure consistent ambient conditions between -25 and +60 degC.

What is the maximum measuring voltage for the EL3413?

It can measure up to 690 V AC in a 3-phase system.

Does the EL3413 perform harmonic analysis?

Yes, it features integrated harmonic analysis as part of its power monitoring capabilities.

What is the adjustable range for the current inputs?

The current measurement range can be adjusted to 100 mA, 1 A (default), or 5 A.

Is the EL3413 suitable for single-phase operation?

Yes, it supports optional single-phase operation in addition to 3-phase measurement.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
سفید خاکستری
Country of origin
آلمان

Recently Viewed Products

Technical knowledge

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و از شبکه‌های PLC، DCS و SCADA از طریق بخش‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...

Factory I/O: یک ابزار شبیه‌سازی PLC مدرن برای آموزش اتوماسیون صنعتی

Factory I/O آموزش PLC را با ارائه شبیه‌سازی‌های صنعتی سه‌بعدی فراگیر برای دانشجویان، مهندسان و تیم‌های نگهداری متحول می‌کند. این پلتفرم فاصله بین نظریه و عمل واقعی اتوماسیون را پر می‌کند و در عین حال...

برنامه‌نویسی چرخه‌های حرکت تک‌محور روی درایو سروو CMZ

این آموزش بررسی می‌کند که چگونه عملکرد PLC داخلی درایو سروو CMZ SBD می‌تواند برنامه‌های حرکتی مستقل را اجرا کند، از جمله منطق خانه‌یابی، کنترل موقعیت و حرکت دوره‌ای محور بدون نیاز به PLC خارجی.

راه‌اندازی کنترل حرکت تک‌محور با درایوهای سروو CMZ

این آموزش به راه‌اندازی سیستم حرکت سروو تک‌محوره با استفاده از درایو CMZ SBD می‌پردازد و شامل تنظیمات سخت‌افزاری، مقیاس‌بندی محور، پیکربندی موقعیت‌یابی اولیه و تأیید حرکت ایمن برای محیط‌های اتوماسیون...