1 of 1

BECKHOFF KL2692 Bus Terminal

BECKHOFF KL2692 Bus Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KL2692

  • Country of origin:آلمان

  • Product Type: Bus Terminal

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

The KL2692 is a multifunctional Bus Terminal from BECKHOFF, combining 2 potential-free relay outputs (normally-open contacts) and 2 digital 24 V DC inputs in a single compact module. This terminal is designed for efficient signal processing and actuator control, allowing for the switching of ohmic or inductive loads up to 5 A (ohmic). With an electrical isolation of 500 V between the K-bus and field potential, the KL2692 ensures reliable separation in complex automation architectures.

Features

  • 2 potential-free relay outputs (normally-open contacts)
  • 2 digital 24 V DC inputs
  • 2-wire connection technology
  • High switching capacity: 5 A ohmic (AC/DC) per channel
  • Minimum load capacity of 10 mA at 5 V DC
  • Mechanical service life of 2 x 10^7 operating cycles
  • Configuration via Bus Coupler or controller
  • Compact IP20-rated housing for DIN rail mounting

Applications

  • Distributed I/O for relay-based logic control
  • Switching of external contactors or solenoids
  • Digital sensor status acquisition combined with output control
  • Automation systems requiring mixed input/output functionality

Technical Specifications

Category Specification
Manufacturer BECKHOFF
Model KL2692
Number of Outputs 2 (relay, NO contacts)
Number of Inputs 2 (digital 24 V DC)
Max. Switching Current (Ohmic) 5 A AC/DC per channel
Max. Switching Current (Inductive) 2 A AC/DC per channel
Nominal Voltage 30 V DC
Current Consumption (K-bus) typ. 165 mA
Electrical Isolation 500 V (K-bus/field potential)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Weight approx. 60 g
Protection Rating IP20

Installation Guidelines

  • Mount the terminal on a 35 mm DIN rail (EN 60715) and secure it using the integrated locking mechanism.
  • Utilize the double slot and key connection for secure side-by-side assembly.
  • Ensure all connections comply with the 2-wire wiring technology requirements.
  • Maintain the ambient operating temperature between 0 and +55 degC to preserve the operational lifespan of the internal relay contacts.
  • Follow EMC standards EN 61000-6-2/EN 61000-6-4 during wiring to prevent signal interference.

Compliance and Certifications

  • CE
  • UL

What is the switching capacity of the relay outputs on the KL2692?

The relay outputs support up to 5 A for ohmic loads and 2 A for inductive loads per channel.

How are the inputs and outputs configured?

Configuration is performed via the Bus Coupler or the host controller.

What is the expected mechanical lifespan of the relays?

The mechanical lifespan is rated for a minimum of 2 x 10^7 operating cycles.

Are the outputs isolated from the K-bus?

Yes, there is 500 V electrical isolation between the K-bus and the field potential.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
سفید
Country of origin
آلمان

Recently Viewed Products

Technical knowledge

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و از شبکه‌های PLC، DCS و SCADA از طریق بخش‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...

Factory I/O: یک ابزار شبیه‌سازی PLC مدرن برای آموزش اتوماسیون صنعتی

Factory I/O آموزش PLC را با ارائه شبیه‌سازی‌های صنعتی سه‌بعدی فراگیر برای دانشجویان، مهندسان و تیم‌های نگهداری متحول می‌کند. این پلتفرم فاصله بین نظریه و عمل واقعی اتوماسیون را پر می‌کند و در عین حال...

برنامه‌نویسی چرخه‌های حرکت تک‌محور روی درایو سروو CMZ

این آموزش بررسی می‌کند که چگونه عملکرد PLC داخلی درایو سروو CMZ SBD می‌تواند برنامه‌های حرکتی مستقل را اجرا کند، از جمله منطق خانه‌یابی، کنترل موقعیت و حرکت دوره‌ای محور بدون نیاز به PLC خارجی.

راه‌اندازی کنترل حرکت تک‌محور با درایوهای سروو CMZ

این آموزش به راه‌اندازی سیستم حرکت سروو تک‌محوره با استفاده از درایو CMZ SBD می‌پردازد و شامل تنظیمات سخت‌افزاری، مقیاس‌بندی محور، پیکربندی موقعیت‌یابی اولیه و تأیید حرکت ایمن برای محیط‌های اتوماسیون...