Integrating serial communication directly into the Beckhoff I/O system, the Beckhoff KL6011 serial interface terminal enables connection to devices equipped with a 20 mA current loop (TTY) interface. The terminal operates fully independently of the higher-level bus system, executing bidirectional transmission of data channels (TxD and RxD) in full duplex mode. The active or passive status of the current loop can be established through external wiring configurations, ensuring high adaptability to legacy serial interfaces, industrial weighing systems, and long-distance terminal connections up to 1000 meters.

Features

  • Active/Passive Flexibility: Configurable 2 x 20 mA active or passive current loops to interface with various sender/receiver architectures.
  • Configurable Baud Rates: Supports transfer rates ranging from 1200 baud up to 19,200 baud to match legacy serial peripherals.
  • Integrated Data Buffering: Equipped with a 128-byte receive buffer and a 16-byte transmit buffer to handle temporary data peaks without processing loss.
  • K-Bus Galvanic Isolation: Provides robust 500 V electrical isolation between the internal K-bus and the field-side signal paths to safeguard control networks.
  • Variable Process Image: Flexible bit-width configuration in the process image (from 3 x 8-bit to 5 x 8-bit user data plus control/status byte).

Applications

  • Legacy Peripheral Integration: Connecting older industrial printers, barcode readers, and display terminals to modern EtherCAT/K-bus architectures.
  • Industrial Weighing Systems: Direct communication with load cells and digital balances that rely on 20 mA current loops.
  • Long-Distance Serial Links: Point-to-point serial communication up to 1000 meters in high-noise environments where RS232 is ineffective.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model / Article Number KL6011
Interface Type TTY (20 mA current loop)
Number of Channels 2 (1 transmit TxD, 1 receive RxD), full duplex
Data Transfer Rates 1200 to 19,200 baud (Default: 9600 baud, 8 data bits, no parity, 1 stop bit)
Bit Transfer Current 2 x 20 mA
Loop Resistance (Load) Less than 500 ohms
Cable Length Max. 1000 m shielded twisted pair
Power Supply Via the internal K-bus
Current Consumption (K-bus) Typical 55 mA
Electrical Isolation 500 V (K-bus to signal voltage)
Process Image Bit Width Input/Output: 3 x 8-bit user data, 1 x 8-bit control/status (up to 5 x 8-bit user data possible)
Protection Class IP20
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Relative Humidity 95%, non-condensing
Ex Marking II 3 G Ex nA IIC T4 Gc
Unit Weight Approx. 60 g
Shipping Weight (Calculated) 0.15 kg
Package Dimensions (Calculated) 125 mm x 80 mm x 25 mm

Connections and Interfaces

Terminal Point Signal / Function Description
1 TxD+ Transmitter current loop output (Positive)
5 TxD- Transmitter current loop return (Negative)
2 RxD+ Receiver current loop input (Positive)
6 RxD- Receiver current loop return (Negative)
3 20 mA Active Tx Internal current source connection for active Tx operation
7 20 mA Active Rx Internal current source connection for active Rx operation

Empirical Engineering Insights

Alternative Models & Compatibility

For applications requiring pluggable wiring terminal structures, the KS6011 represents the direct functional alternative, retaining the exact same internal logic and register mapping. If your infrastructure utilizes RS485 or RS232 protocols rather than 20 mA current loops, migrate to the KL6021 or KL6001 terminals, respectively, as the KL6011 electrical physical layer is restricted strictly to TTY communication.

Application Pitfalls & Engineering Notes

A frequent commissioning failure involves improper active/passive configuration of the 20 mA current loop. Because a TTY loop requires exactly one current source to function, placing two active devices on the same loop will cause hardware damage or component burnout due to overcurrent. Ensure that if the connected external device is active (supplying the loop current), the KL6011 is wired strictly in its passive configuration (avoiding terminals 3 and 7).

Commissioning & Wiring Tips

To optimize transmission reliability up to the 1000 m limit, use low-capacitance, shielded twisted-pair (STP) cabling. Connect the shield on one end only—ideally at the Bus Coupler ground rail—to prevent ground loops. Note that configuration of the data format (baud rate, parity, stop bits) is managed dynamically via the terminal registers using TwinCAT or alternative coupler configuration software, requiring no physical dip-switch adjustments on the hardware block.

Installation Guidelines

CRITICAL WARNING

Disconnect all electrical supplies before inserting or removing terminals from the K-bus assembly. Failure to isolate the power contacts can lead to permanent damage of the bus contacts, the bus coupler, or the adjacent I/O modules.

1
Ensure the DIN rail is securely grounded to the main cabinet ground system to facilitate proper EMC shielding.
2
Mount the terminal onto the DIN rail by aligning the integrated tongue-and-groove slot with the neighboring terminal and pushing firmly until it clicks.
3
Use a flathead screwdriver to depress the spring-loaded wire clamps, insert the pre-stripped signal wires, and release to secure.
Loading product navigation…

Can the KL6011 be used to interface with an RS232 device?

No, it is strictly designed for TTY 20 mA current loop interfaces. To connect to an RS232 device, use the Beckhoff KL6001 module.

How do I configure the active or passive status of the current loop on this terminal?

The configuration is determined by the external physical wiring of the terminals. Connecting to the internal 20 mA sources on terminals 3 and 7 configures the circuit as active. Leaving them disconnected runs the loop as passive.

What is the maximum distance supported by the serial interface?

It supports communication distances up to 1000 meters when utilizing high-quality shielded twisted-pair cabling.

Is an external power supply required for the field-side serial loop?

No, the internal logic and active loop current (if utilized via terminals 3 and 7) are powered directly through the standard K-bus.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
آلمان

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های نیروی سیال: راهنمای عملی اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...