1 از 3

Bently Nevada 330106-05-30-50-12-CN 3300 XL 8 mm Reverse Mount Proximity Probe

Bently Nevada 330106-05-30-50-12-CN 3300 XL 8 mm Reverse Mount Proximity Probe

فقط 7 قلم کالا در انبار باقی مانده است
  • تولیدکننده: Bently Nevada

  • شماره محصول: 330106-05-30-50-12-CN

  • کشور سازنده:ایالات متحده آمریکا

  • نوع محصول: 3300 XL 8 mm Reverse Mount Probes

  • بارکد: 8537101190

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 1650g

  • ابعاد: 250 mm x 250 mm x 50 mm (H x W x D)

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

Option 05 (5.0 mm unthreaded length), Option 30 (30 mm case length), Option 50 (5.0 m total length), and Option 12 (ClickLoc connector with FluidLoc cable) specify this 330106-05-30-50-12-CN 3300 XL 8 mm Reverse Mount Proximity Probe with China hazardous area approvals (-CN).

This reverse-mount probe configuration features M10 x 1 metric threads and is engineered for installation inside machine casings or sleeves where standard forward-mounting is physically restricted. Unlike standard probes utilizing standard coaxial cables, this variant integrates a FluidLoc cable (Option 12), which provides a block against oil or process fluids from migrating along the cable via capillary action. Additionally, the 5.0-meter integral probe cable (Option 50) matches perfectly with a 5-meter 3300 XL Proximitor sensor, eliminating the need for an intermediate extension cable in specific turbine housing mounting layouts.

Features

  • Option 05 unthreaded length provides a precise 5.0 mm (0.20 in) clearance at the mounting base.
  • Option 30 case length specifies a 30 mm (1.2 in) total metric threaded housing of M10 x 1 thread size.
  • Option 50 designates a 5.0-meter (16.4 feet) total integral probe cable length for direct connection to 5-meter Proximitor systems.
  • Option 12 incorporates a FluidLoc cable and a miniature coaxial ClickLoc connector to halt oil leakage along the cable core.
  • Suffix -CN certifies the assembly for China hazardous area environments under NEPSI and CCC regulations.
  • Polyphenylene sulfide (PPS) probe tip provides chemical and thermal isolation up to 177 degC (350 degF).
  • AISI 303 or 304 stainless steel case offers structural protection in high-vibration machinery casings.

Applications

  • Axial position and radial vibration measurements in heavy industrial rotating machinery.
  • High-pressure casing penetration where FluidLoc technology prevents lubricating oil migration.
  • Reverse-mount turbine bearing housing installations with limited external access.
  • Petrochemical and power generation installations in China requiring NEPSI and CCC hazardous area compliance.

Ordering Information

Option Segment Code Value Meaning / Description
Orderable Part Number 330106-05-30-50-12-CN 3300 XL 8 mm Reverse Mount Proximity Probe (M10 x 1 threads)
Segment A (Unthreaded Length) 05 5.0 mm (0.20 in) unthreaded length
Segment B (Overall Case Length) 30 30 mm (1.2 in) case length
Segment C (Total Length) 50 5.0 meters (16.4 feet) total length
Segment D (Connector & Cable) 12 Miniature ClickLoc coaxial connector, FluidLoc cable
Suffix -CN (Agency Approval) -CN China hazardous area approval package (NEPSI + CCC)

Technical Specifications

Parameter Specification Value
Manufacturer Bently Nevada (Baker Hughes)
Part Number 330106-05-30-50-12-CN
Probe Tip Diameter 8.0 mm (0.31 in)
Thread Size M10 x 1 (Metric)
Unthreaded Length 5.0 mm (0.20 in)
Overall Case Length 30 mm (1.2 in)
Total Probe Length 5.0 meters (16.4 feet)
Cable Type 75 Ohm FluidLoc triaxial cable
Connector Type Miniature ClickLoc coaxial connector
Probe Tip Material Polyphenylene sulfide (PPS)
Probe Case Material AISI 303 or 304 stainless steel (SST)
Operating Temperature (Probe) -52 degC to +177 degC (-62 degF to +350 degF)
Maximum Rated Pressure Designed to seal differential pressure between tip and case
Tensile Strength (Maximum Rated) 330 N (75 lbf) probe case to probe lead; 270 N (60 lbf) lead to connectors
Minimum Cable Bend Radius 25.4 mm (1.0 in)
Connector Torque (Maximum) 0.565 Nm (5 in-lbf)
Probe Case Torque (Maximum) 22.6 Nm (200 in-lbf) for reverse-mount probes
Nominal DC Resistance 7.45 to 9.87 Ohms depending on overall circuit (8.73 Ohms typical for 5.0m probe)
Dimensions 250 mm x 250 mm x 50 mm (H x W x D) (coiled probe envelope)
Weight 1.65 kg (3.64 lb)

Installation Guidelines

  • Reverse-mount probes are installed from the inside or inside a dedicated probe sleeve/housing.
  • Observe the minimum permissible cable bend radius of 25.4 mm (1.0 in) to prevent internal conductor damage.
  • Hand-tighten the ClickLoc coaxial connector to avoid stripping gold-plated surfaces; do not exceed 0.565 Nm (5 in-lbf).
  • Mount the probe-to-extension cable junction in a clean dry location; avoid exposing connectors directly to aggressive turbine lubricating oil without a protective sleeve.
  • Ensure the probe case torque does not exceed 22.6 Nm (200 in-lbf) during reverse-mount seating in the M10 x 1 threaded housing.

Compliance and Certifications

  • NEPSI (National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation)
  • CCC (China Compulsory Certification)
  • Hazardous area explosion-proof markings as specified by the -CN package
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330106-05-30-50-12-CN 3300 XL 8 mm Reverse Mount Proximity Probe

What does the "12" connector option represent on this probe?

The Option 12 code specifies a miniature ClickLoc coaxial connector paired with a FluidLoc cable. This specialized cable prevents machinery oil or process fluids from leaking or migrating along the cable core via capillary action.

Why is this model termed a reverse-mount probe?

The reverse-mount configuration (model 330106) has the threads positioned near the probe tip instead of the back of the case. This allows the probe to be installed through the inside of machine housings or sleeves where standard external thread mounting is not feasible.

Can this 5.0-meter probe be used with a 9-meter Proximitor sensor?

No, 5.0-meter proximity probes are engineered specifically for use with a 5-meter Proximitor sensor only. Operating this probe with a 9-meter sensor will disrupt system calibration and cause incorrect output.

What certifications does the -CN suffix provide?

The -CN suffix designates the China hazardous area approval package, which includes official NEPSI explosion-proof certification and CCC (China Compulsory Certification) markings for industrial installations in China.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً صفحه رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
ایالات متحده آمریکا

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های قدرت سیال: راهنمای عملی اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدولو و توان را در اتوماسیون صنعتی انجام می‌دهند. همچنین نشان می‌دهد که چگونه این بلوک‌های عملکردی...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع درباره فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکو و گیره‌های نرم با درجه‌بندی غذایی گرفته تا ابزارهای انبارداری مجهز به هوش مصنوعی،...