| Manufacturer |
Bently Nevada (Baker Hughes) |
| Part Number |
330881-28-11-214-00-02 |
| Transducer Type |
Metric PROXPAC XL Integrated Proximity Transducer |
| Proximitor Input |
3300 XL 8 mm Proximity Probe, 1-meter cable length |
| Input Voltage |
-17.5 Vdc to -26 Vdc (without barriers), -23 Vdc to -26 Vdc (with barriers) |
| Current Consumption |
12 mA maximum |
| Output Resistance |
50 ohms |
| Probe DC Resistance |
7.59 +/- 0.50 ohms (center to outer conductor) |
| Field Wiring Compatibility |
0.2 to 1.5 mm2 (16 to 24 AWG), 3-conductor shielded triax recommended |
| Maximum Field Wiring Distance |
305 meters (1,000 feet) between Proximitor sensor and monitor |
| Linear Range |
2.0 mm (80 mils), from approximately 0.25 mm (10 mils) to 2.3 mm (90 mils) |
| Recommended Gap Setting |
1.27 mm (50 mils) |
| Incremental Scale Factor (ISF) |
7.87 V/mm (200 mV/mil) +/- 5% (0 degC to +45 degC) |
| Deviation from Best Fit Straight Line (DSL) |
Less than +/-0.025 mm (+/-1 mil) at 0 degC to +45 degC |
| Frequency Response |
0 to 10 kHz (+0, -3 dB) with up to 305 meters of field wiring |
| Minimum Shaft Diameter |
50.8 mm (2.0 in) |
| Minimum Target Size |
15.2 mm (0.6 in) diameter (flat target) |
| Housing Material |
Glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers (UV resistant) |
| Outer Sleeve Material |
AISI 304 stainless steel |
| Sleeve O-Ring Material |
Neoprene |
| Probe Tip Material |
Polyphenylene Sulfide (PPS) |
| Probe Case Material |
AISI 304 stainless steel |
| Probe Cable Type |
75 ohm triaxial, FEP insulated, 1-meter length |
| Grounding Liner Material |
AISI 304 stainless steel |
| Isolation Material |
Extra Soft Cellular Silicone |
| Environmental Rating |
Type 4X and IP66 |
| Operating Temperature (Probe) |
-52 degC to +177 degC (exposing below -34 degC may affect pressure seal) |
| Operating Temperature (Housing/Sensor) |
-52 degC to +100 degC |
| Storage Temperature |
-52 degC to +105 degC |
| Relative Humidity |
100% condensing, non-submersible (when properly sealed) |
| Retaining Nut Torque |
29.5 N-m (260 in-lb) |
| Probe Sleeve Locknut Torque |
39.3 N-m (350 in-lb) |