| Manufacturer |
Bently Nevada (Baker Hughes) |
| Model / Part Number |
330881-28-20-040-03-02 |
| Proximitor Sensor Input |
3300 XL 8 mm Proximity Probe with a 1-metre cable length installed in the probe sleeve |
| Power Requirements |
Requires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum; -23 Vdc to -26 Vdc with barriers |
| Supply Sensitivity |
Less than 2 mV change in output voltage per volt change in input voltage |
| Output Resistance |
50 Ohm |
| Nominal Probe DC Resistance |
7.59 +/- 0.50 Ohm (center conductor to outer conductor) |
| Field Wiring Compatibility |
0.2 to 1.5 mm2 (16 to 24 AWG). Supports up to 305 metres (1,000 feet) between Proximitor and monitor. Standard 3-conductor shielded triax recommended. |
| Linear Range |
2 mm (80 mils), starting at approximately 0.25 mm (10 mils) from target (0.25 mm to 2.3 mm; approx -1 Vdc to -17 Vdc) |
| Recommended Gap Setting |
1.27 mm (50 mils) |
| Incremental Scale Factor (ISF) |
7.87 V/mm (200 mV/mil) +/- 5% over the linear range from 0 degC to +45 degC |
| Deviation from Best Fit Straight Line (DSL) |
Less than +/-0.025 mm (+/-1 mil) from 0 degC to +45 degC |
| Frequency Response |
0 to 10 kHz: +0, -3 dB with up to 305 metres (1,000 feet) of field wiring |
| Minimum Target Size |
15.2 mm (0.6 in) diameter (flat target) |
| Minimum Shaft Diameter |
50.8 mm (2.0 in) |
| Housing Material |
Ultraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers |
| Probe Case & Sleeve Material |
AISI 304 stainless steel |
| Outer Sleeve & Retaining Screws |
AISI 303 stainless steel |
| Sleeve O-Ring Material |
Neoprene |
| Grounding Liner Material |
AISI 304 stainless steel |
| Vibration Isolation Material |
Extra Soft Cellular Silicone |
| Operating Temperature (Probe) |
-52 degC to +177 degC (-62 degF to +351 degF) |
| Operating Temperature (Housing & Sensor) |
-52 degC to +100 degC (-62 degF to +212 degF) |
| Storage Temperature Range |
-52 degC to +105 degC (-62 degF to +221 degF) |
| Relative Humidity Limit |
100% condensing, non-submersible when connectors are protected |
| Housing IP / Type Rating |
Type 4X and IP66 rated |