Fully threaded 3/8-24 UNF steel probe body (Option 00) with a 3.6-inch overall case length (Option 36) and a 0.5-meter total probe length (Option 05) specifies this exact 330908-00-36-05-02-05-05 3300 NSv Proximity Probe configuration. Used in compact machinery applications with restricted installation space or small shaft targets, this proximity probe provides non-contact displacement measurements for critical shaft vibration and axial position parameters.

This unarmored base configuration (330908) includes a miniature coaxial ClickLoc connector on standard FEP-insulated cable (Option 02) and is built with multiple international hazardous area certifications (Option 05). Designed to pair with the Bently Nevada 330930 extension cable and the 330980 Proximitor sensor, this transducer system is used where standard 8 mm probes are too large, or where machinery geometries present severe counterbore restrictions.

Features

  • Fully threaded 3/8-24 UNF-2A body (Option 00 unthreaded length) ensuring maximum mounting flexibility.
  • 3.6-inch overall case length (Option 36) providing the rigid depth required for deep-seated machine casing installations.
  • 0.5-meter (20-inch) total probe length (Option 05) reducing intermediate cabling slack in close-coupled installations.
  • Miniature coaxial ClickLoc connector (Option 02) establishing a solid, low-noise connection with the system extension cable.
  • Multiple hazardous area approvals (Option 05) certifying the transducer for intrinsically safe and non-incendive zones.
  • High-stability polyphenylene sulfide (PPS) tip construction with a 3.2 mm diameter optimized for tight targets and small shafts.

Applications

  • Centrifugal compressors and high-speed pumps with shaft diameters smaller than 30 mm.
  • Aeroderivative gas turbine vibration and thrust position monitoring.
  • Industrial machinery installations where tight mechanical clearances or narrow counterbores restrict standard probe sizes.
  • Auxiliary rotating machinery requiring reliable non-contact eddy-current shaft displacement tracking.

Ordering Information

Option Segment Code Configuration Meaning
Base Model 330908 3300 NSv Proximity Probe, 3/8-24 UNF thread, without armor
Segment A: Unthreaded Length 00 0.0 in (0 mm) unthreaded length (fully threaded case)
Segment B: Overall Case Length 36 3.6 in (91 mm) overall case length
Segment C: Total Length 05 0.5 meter (20 inches) total length
Segment D: Connector and Cable 02 Miniature coaxial ClickLoc connector, standard cable
Segment E: Agency Approval 05 Multiple Approvals (including CSA, ATEX, and IECEx)
Segment F: Configuration Suffix 05 Standard multiple approvals configuration suffix

Technical Specifications

Manufacturer Bently Nevada (Baker Hughes)
Part Number 330908-00-36-05-02-05-05
Transducer System 3300 XL NSv Proximity Transducer System
Thread Size 3/8-24 UNF-2A
Armor Configuration Unarmored (without armor)
Unthreaded Length 0.0 in (0 mm)
Case Length 3.6 in (91.4 mm)
Total Probe Length 0.5 meters (20 inches)
Connector Type Miniature male coaxial ClickLoc connector
Cable Type 75 ohm coaxial, FEP insulated, standard cable
Probe Tip Material Polyphenylene sulfide (PPS)
Probe Case Material AISI 304 stainless steel (SST)
Linear Range 1.5 mm (60 mils), from 0.25 to 1.75 mm (10 to 70 mils)
Recommended Gap Setting 1.0 mm (40 mils)
Incremental Scale Factor (ISF) 7.87 V/mm (200 mV/mil) nominal
Deviation from Best Fit Straight Line (DSL) Less than +/-0.06 mm (+/-2.3 mils) over linear range
Operating Temperature -55 degC to +177 degC (-67 degF to +350 degF)
System Input Voltage -17.5 Vdc to -26 Vdc (without safety barriers), -23 Vdc to -26 Vdc (with safety barriers)
Maximum Current Consumption 12 mA
Tensile Strength 220 N (50 lb) maximum rated (probe case to lead)
Frequency Response 0 to 10 kHz: +0, -3 dB typical
Hazardous Area Approvals Multiple Approvals (Option 05: CSA, ATEX, IECEx)

Installation Guidelines

  • Set the probe-to-target gap to 1.0 mm (40 mils) to establish the -9.0 Vdc nominal bias center point of the linear range.
  • Ensure that thread tightening torque on the 3/8-24 UNF-2A stainless steel body is kept within recommended engineering limits to prevent threads from seizing or stripping.
  • Maintain recommended bend radiuses when routing the 75 ohm coaxial FEP-insulated probe cable; do not pinch or expose cable to high-abrasion surfaces.
  • When installing multiple probes, maintain a minimum tip separation of 25 mm (1.0 in) for axial position or 23 mm (0.9 in) for radial vibration to prevent electromagnetic cross-talk.
  • Protect the ClickLoc connector from machine oils and contaminants; applying a connector protector or silicone self-fusing tape (Bently catalog number 03200006) is recommended for external routing.

Compliance and Certifications

  • EMC Directive 2014/30/EU (EN 61000-6-2 and EN 61000-6-4)
  • RoHS Directive 2011/65/EU and China RoHS EFUP 15 years
  • Functional Safety: SIL 2 (HFT = 0) and SIL 3 (HFT = 1) capability
  • ATEX/IECEx: Ex ia IIC T5...T1 Ga for Zone 0 installations; Ex ec/nA IIC T5...T1 Gc for Zone 2 installations
  • North American (cNRTLus): Class I, Zone 0: AEx/Ex ia IIC T5...T1 Ga; Class I, Division 1 & 2, Groups A, B, C, and D
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

پراب نزدیکی Bently Nevada 330908-00-36-05-02-05-05 3300 NSv

What thread type and case dimensions are specified on the 330908-00-36-05-02-05-05 probe?

This probe features a 3/8-24 UNF-2A thread, a 0.0-inch unthreaded length (fully threaded case), and a 3.6-inch overall case length.

What is the total length of the cable attached to this probe?

The total length is 0.5 meters (20 inches), matching total length Option 05.

What type of connector is supplied with this specific probe?

It features a miniature coaxial ClickLoc connector on standard (unarmored) cable, which matches connector Option 02.

Does this probe carry hazardous area certifications?

Yes, this configuration is supplied with Option 05, certifying it for multiple international hazardous area approvals including CSA, ATEX, and IECEx.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً صفحه رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
ایالات متحده آمریکا

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های قدرت سیال: راهنمای عملی اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدولو و توان را در اتوماسیون صنعتی انجام می‌دهند. همچنین نشان می‌دهد که چگونه این بلوک‌های عملکردی...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع درباره فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکو و گیره‌های نرم با درجه‌بندی غذایی گرفته تا ابزارهای انبارداری مجهز به هوش مصنوعی،...