Description

The Danfoss 060L313066 is a KPS80 series temperature control unit engineered for robust monitoring and regulation in demanding industrial environments. This temperature switch features an adjustable differential and is equipped with a 5000 mm capillary tube, providing flexibility for remote sensing applications. Designed for high reliability, the unit utilizes an adsorption charge and includes an SPDT gold contact configuration, making it suitable for low-current control circuits as well as standard switching operations. The housing is protected with armoring and includes a metal cable gland with a Pg 13.5 screwed cable entry for secure electrical connection.

Features

  • Model: KPS80 Temperature Control
  • Sensing Range: 70 to 120 degC
  • Capillary Tube Length: 5000 mm
  • Contact Configuration: SPDT Gold
  • Enclosure Protection: Armoring included
  • Electrical Connection: Screwed cable entry (Pg 13.5)
  • Connection Type: M 18 x 1.5 for pocket or hose
  • Charge Type: Adsorption

Applications

  • Industrial boilers and heat exchangers
  • Marine cooling and heating systems
  • Process plant temperature monitoring
  • Hydraulic power units
  • Compressor temperature regulation

Technical Specifications

Feature Specification
Manufacturer Danfoss
Product Model 060L313066
Temperature Range 70 to 120 degC
Ambient Temperature -40 to 70 degC
Capillary Tube Length 5000 mm
Differential Type Adjustable
Contact Rating (AC1) 10 A, 440 V
Contact Rating (AC3) 6 A, 440 V
Contact Rating (AC15) 4 A, 440 V
Contact Rating (DC13) 12 W, 220 V
Gold Contact Range 1 to 30 mA, 5 to 30 V
Weight 2.5 Kg

Installation Guidelines

  • Mounting: Ensure the sensing element is installed in a location representative of the process temperature. Secure the capillary tube to prevent mechanical damage or excessive vibration.
  • Connection: The M 18 x 1.5 connection is designed for use with a thermowell (pocket) or hose to ensure accurate temperature transfer and environmental sealing.
  • Cable Entry: Utilize the provided Pg 13.5 metal cable gland to maintain the integrity of the electrical connection against dust and moisture.
  • Calibration: Adjust the temperature setting and differential according to the specific requirements of the process loop.
  • Ambient Limits: Ensure the ambient temperature of the control housing remains within the -40 degC to 70 degC range. Note that the unit can withstand 80 degC for a maximum of 120 minutes.

What is the primary application for the gold contacts in this unit?

The SPDT gold contacts are specifically designed for low-current applications, typically ranging from 1 mA to 30 mA at 5 V to 30 V, ensuring reliable switching in sensitive control circuits.

Can this unit withstand ambient temperatures above 70 degC?

The operating ambient temperature range is -40 degC to 70 degC. It can withstand a maximum of 80 degC for up to 120 minutes.

Does this model include a protection pocket?

The unit features an M 18 x 1.5 connection for a pocket or hose, but the pocket itself must be sourced according to specific installation requirements.

What is the function of the adsorption charge?

The adsorption charge is the sensing medium inside the capillary system that reacts to temperature changes to actuate the switch contact.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
ایالات متحده آمریکا

Recently Viewed Products

Technical knowledge

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و از شبکه‌های PLC، DCS و SCADA از طریق بخش‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...

Factory I/O: یک ابزار شبیه‌سازی PLC مدرن برای آموزش اتوماسیون صنعتی

Factory I/O آموزش PLC را با ارائه شبیه‌سازی‌های صنعتی سه‌بعدی فراگیر برای دانشجویان، مهندسان و تیم‌های نگهداری متحول می‌کند. این پلتفرم فاصله بین نظریه و عمل واقعی اتوماسیون را پر می‌کند و در عین حال...

برنامه‌نویسی چرخه‌های حرکت تک‌محور روی درایو سروو CMZ

این آموزش بررسی می‌کند که چگونه عملکرد PLC داخلی درایو سروو CMZ SBD می‌تواند برنامه‌های حرکتی مستقل را اجرا کند، از جمله منطق خانه‌یابی، کنترل موقعیت و حرکت دوره‌ای محور بدون نیاز به PLC خارجی.

راه‌اندازی کنترل حرکت تک‌محور با درایوهای سروو CMZ

این آموزش به راه‌اندازی سیستم حرکت سروو تک‌محوره با استفاده از درایو CMZ SBD می‌پردازد و شامل تنظیمات سخت‌افزاری، مقیاس‌بندی محور، پیکربندی موقعیت‌یابی اولیه و تأیید حرکت ایمن برای محیط‌های اتوماسیون...