1 از 1

Omron CJ1W-AD081-V1 CJ1 Series Analog Input Unit

Omron CJ1W-AD081-V1 CJ1 Series Analog Input Unit

فقط 3 قلم کالا در انبار باقی مانده است
  • تولیدکننده: Omron

  • شماره محصول: CJ1W AD081-V1

  • کشور سازنده:ژاپن

  • نوع محصول: Analog Input Modules

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 150g

  • ابعاد: 31 mm x 90 mm x 89 mm

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

For high-density process data acquisition in industrial environments, the CJ1W-AD081-V1 serves as a reliable multi-channel analog input unit within the Sysmac CJ-series PLC platform. This module supports up to eight analog input channels on a single slot, making it highly efficient for cabinets with limited footprint. It interfaces directly with CJ1, CJ2, and compatible CPU racks via the system bus, facilitating rapid data transfers and streamlined diagnostic monitoring.

Each channel can be independently configured for different input signal types, allowing engineers to mix voltage and current signals on the same physical module. Key processing functions integrated directly into the hardware include scaling, peak hold, mean value processing, and input wire-disconnection detection, which reduces the computational load on the main CPU.

Features

  • Supports up to 8 analog input channels in a compact single-slot width.
  • Independently configurable inputs for voltage (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V) and current (4 to 20 mA).
  • High-speed conversion rate of 250 microseconds per point (2 milliseconds total for all 8 points).
  • High-resolution conversion mode up to 1/8000 (standard mode is 1/4000) for precise application control.
  • Built-in digital filter function to suppress high-frequency process noise.
  • Peak hold and valley hold functions for tracking transient process limits.
  • Disconnection detection feature for 1 to 5 V and 4 to 20 mA input signals.

Applications

  • Multi-zone temperature tracking and monitoring in thermal processing.
  • Flow rate, level, and pressure transmitter integration in water treatment systems.
  • Feedback control loops in plastic extrusion and chemical dosing machinery.
  • Factory automation and process monitoring systems requiring high-density analog acquisition.

Technical Specifications

ManufacturerPart Number/ModelSeriesModule TypeNumber of InputsInput Ranges (Voltage)Input Ranges (Current)Input Impedance (Voltage)Input Impedance (Current)ResolutionConversion SpeedAccuracy (at 25 degC)IsolationExternal ConnectionsCurrent ConsumptionDimensionsWeightOperating Temperature
Omron
CJ1W-AD081-V1
CJ Series (CJ1, CJ2)
Analog Input Unit (Special I/O Unit)
8 points
1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V
4 to 20 mA
1 MOhm minimum
250 Ohm rated resistance
1/4000 (standard mode), 1/8000 (high-resolution mode)
250 microseconds/point max.
Voltage: +/-0.2% of F.S. | Current: +/-0.4% of F.S.
Photocoupler isolation between input terminals and PLC internal bus (no isolation between individual input channels)
18-point terminal block (detachable)
420 mA max. at 5 VDC (supplied via backplane)
31 mm x 90 mm x 89 mm (W x H x D)
150 g (excluding shipping packaging)
0 to 55 degC

Connections and Interfaces

The unit features an 18-point detachable terminal block. Users can pre-wire the block before attaching it to the module. Terminal mappings should follow standard instrumentation wiring layouts:

Terminal Pair Signal Designation Description
A1 / B1 V IN 1 / I IN 1 Input 1 Voltage (+) / Input 1 Current (+)
A2 / B2 COM 1 Input 1 Common (-)
A3 / B3 V IN 2 / I IN 2 Input 2 Voltage (+) / Input 2 Current (+)
A4 / B4 COM 2 Input 2 Common (-)
A5 / B5 V IN 3 / I IN 3 Input 3 Voltage (+) / Input 3 Current (+)
A6 / B6 COM 3 Input 3 Common (-)
A7 / B7 V IN 4 / I IN 4 Input 4 Voltage (+) / Input 4 Current (+)
A8 / B8 COM 4 Input 4 Common (-)
A9 / B9 NC / SLD No Connection / Shield Ground Terminal

Note: Terminals A10 through B18 follow a repeating functional layout for Inputs 5 through 8. When using current inputs, short-circuit the voltage input (V IN) and current input (I IN) terminals for that channel.

Installation Guidelines

  • Always switch off the PLC system power supply before mounting or removing the module from the rack.
  • Ensure the slide locks on the top and bottom of the unit are securely locked into the adjacent modules.
  • To prevent electromagnetic interference, use shielded twisted-pair (STP) cables for all analog signal runs.
  • Route analog I/O wiring separately from high-voltage, high-current AC power cables.
  • Connect the shield wire of the input cables to the shield terminal (SLD) or ground them at the panel entry point.

Compliance and Certifications

  • CE Mark Directive compliant
  • UL and cULus listed
  • Lloyd's Register approved for marine installations
Loading product navigation…

What is the conversion speed of the CJ1W-AD081-V1?

The module features a fast conversion speed of 250 microseconds per point, meaning all 8 channels can be processed in 2 milliseconds.

Can I mix voltage and current input signals on the same CJ1W-AD081-V1 unit?

Yes. Each of the 8 channels can be configured independently for voltage or current input types using the PLC software settings.

How do I wire a current input channel instead of a voltage input?

To configure a channel for current input (4 to 20 mA), you must short-circuit the Voltage Input (V IN) and Current Input (I IN) terminals for that specific channel, then connect the signal source to these combined terminals and the common (COM) terminal.

Does this module require an external power supply?

No. The CJ1W-AD081-V1 draws its operational power directly from the 5 VDC internal bus of the CJ-series PLC backplane.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
ژاپن

محصولات مشاهده‌شده اخیر

دانش فنی

عملگرهای الکتریکی طراحی شده برای جایگزینی سیستم‌های نیروی سیال: راهنمای عملی اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه عملگرهای الکتریکی یکپارچه، مانند سری e-Actuator شرکت SMC، در حال تحول کنترل حرکت صنعتی با جایگزینی سیستم‌های سنتی پنوماتیک و هیدرولیک هستند. این مقاله به بهبود دقت...

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...