1 از 1

Omron NX-TS2102 NX Series Temperature Input Unit

Omron NX-TS2102 NX Series Temperature Input Unit

فقط 4 قلم کالا در انبار باقی مانده است
  • تولیدکننده: Omron

  • شماره محصول: NX-TS2102

  • کشور سازنده:ژاپن

  • نوع محصول: Temperature Input Units

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 70g

  • ابعاد: 12 (W) x 100 (H) x 71 (D) mm

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

Designed for high-speed thermal monitoring within the Sysmac automation platform, the Omron NX-TS2102 delivers high-resolution temperature data acquisition directly to the NX bus interface. This 2-point thermocouple input unit enables real-time temperature tracking with an ultra-low conversion cycle time of 10 ms per unit, making it an excellent choice for dynamic closed-loop heating and cooling processes. Utilizing a screwless clamping terminal block with 16 connection terminals, the module simplifies field commissioning while ensuring vibration-resistant wire terminations in demanding industrial environments.

Features

  • Dual-Channel Input: Supports two independent thermocouple input points within a compact 12 mm wide profile.
  • Rapid Conversion Speed: Achieves a fast 10 ms conversion time per Unit for rapid thermal response loop configurations.
  • High-Resolution Measurement: Yields a maximum resolution of 0.01 degC for highly precise process regulation.
  • Universal Thermocouple Compatibility: Directly interfaces with K, J, T, E, L, U, N, R, S, WRe5-26, and PLII sensor types.
  • Robust Isolation: Employs galvanic isolation via a transformer and digital isolator between inputs and the internal NX bus, as well as channel-to-channel.
  • Free-Run Refreshing: Leverages the Free-Run I/O refreshing method for continuous, non-synchronized background processing.

Applications

  • Plastic Extrusion & Injection Molding: High-precision barrel zone temperature control.
  • Packaging Machinery: Thermal management of sealing jaws and shrink wrapping heating elements.
  • Industrial Ovens & Furnaces: Multi-zone heat treatment profile logging and burner control.
  • Semiconductor Processing: Critical ambient chamber thermal monitoring and stability analysis.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number NX-TS2102
Series NX I/O System
Unit Type Temperature Input Unit (Thermocouple Type)
Number of Inputs 2 channels
Conversion Time 10 ms / Unit
Resolution 0.01 degC maximum
Input Conversion Range +/-20 degC of the nominal sensor input range
Input Impedance 20 kOhm minimum
Absolute Maximum Rating +/-130 mV
Disconnection Detection Current Approximately 0.1 uA
Warm-up Period 45 minutes
Isolation Method Power: Transformer; Signal: Digital Isolator (Input-to-NX Bus and Channel-to-Channel)
Insulation Resistance 20 MOhm minimum between isolated circuits (at 100 VDC)
Dielectric Strength 510 VAC between isolated circuits for 1 minute (leakage current 5 mA max)
NX Unit Power Consumption 1.15 W max (on CPU/Control Unit); 0.80 W max (on Coupler Unit)
Module Dimensions 12 mm (W) x 100 mm (H) x 71 mm (D)
Net Weight 0.07 kg
Country of Origin Japan
Shipping Weight (Calculated) 1.00 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The NX-TS2102 is highly compatible across the entire Sysmac platform, including NX102, NX1P2, and NJ series controllers when utilizing EtherCAT or EtherNet/IP coupler units. If your process requires RTD sensors (such as Pt100) instead of thermocouples, consider the alternative NX-TS2101 model. For installations requiring higher density in a single slot, the 4-channel NX-TS3102 is a direct functional alternative with similar conversion characteristics.

Application Pitfalls & Engineering Notes

To achieve the specified maximum conversion resolution of 0.01 degC, the module requires a warm-up period of 45 minutes after system start-up. In high-density control enclosures, avoid placing high-power components (like contactors, variable frequency drives, or power supplies) immediately adjacent to the temperature unit, as localized thermal radiation can distort the built-in cold junction compensation (CJC) reference reading.

Commissioning & Wiring Tips

When wiring the 16-pin screwless terminal block, ensure that thermocouple extension wires match the correct alloy chemistry of the sensor type (e.g., K-type extension wire for K-type thermocouples) up to the terminal clamp to prevent parasitic junctions. Shielded thermocouple cables should be used, with the shield terminated at a single low-impedance ground point to minimize electrical noise induced from adjacent mains wiring.

Installation Guidelines

CRITICAL WARNING

Always isolate all system power sources (mains supply and external I/O power) before inserting or removing the module from the NX bus rack assembly. Failure to completely de-energize the unit during terminal maintenance or expansion may cause permanent damage to the integrated digital isolators or interrupt synchronous communication on the active backplane.

1

Mount the module onto the standard 35 mm DIN rail. Engage the upper hook of the NX Unit connector with the DIN rail, then press downward until the locking lever clicks securely into position.

2

Connect the adjacent NX Units together, sliding them firmly until the side-plane bus connectors link cleanly. Secure the end plate on the rightmost unit of the assembly.

3

Perform wiring of the thermocouple cables using solid wires or ferrules. Insert a flat-blade screwdriver into the terminal release hole, insert the stripped wire into the clamp terminal, and release the screwdriver to lock.

Loading product navigation…

What sensor types are natively supported by the NX-TS2102?

The module natively supports K, J, T, E, L, U, N, R, S, WRe5-26, and PLII thermocouple types, selectable via software configuration in Sysmac Studio.

Does this thermocouple unit require an external power supply?

No, the unit draws its operating power directly from the NX bus connection and does not require an external I/O power supply.

How long does the NX-TS2102 take to warm up for high-accuracy readings?

It requires a warm-up period of at least 45 minutes to ensure internal thermal equilibrium and reliable Cold Junction Compensation (CJC).

What is the conversion cycle speed for this temperature module?

The conversion time is 10 ms per Unit, enabling high-speed temperature updates for critical control systems.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه پردازش و تحویل داده می‌شوند (به جز تعطیلات رسمی).


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً سیاست رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
ژاپن

محصولات مشاهده‌شده اخیر

دانش فنی

عملیات ریاضی با استفاده از OpenPLC برای کاربردهای اتوماسیون صنعتی

این مقاله توضیح می‌دهد که چگونه سیستم‌های PLC عملیات ریاضی اصلی مانند جمع، تفریق، ضرب، تقسیم، مدول و توان را در اتوماسیون صنعتی انجام می‌دهند. نشان می‌دهد که چگونه این بلوک‌های عملکردی سیگنال‌های خام...

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و با استفاده از تقسیم‌بندی، کنترل ورودی/خروجی و ادغام IDS/IPS مطابق با اصول IEC 62443، از شبکه‌های PLC، DCS و SCADA محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...