1 / 3

Allen-Bradley 1797-IE8 FLEX Ex Intrinsically Safe Analog Input Module

Allen-Bradley 1797-IE8 FLEX Ex Intrinsically Safe Analog Input Module

Only 2 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1794-OB16

  • Country of origin:Egyesült Államok

  • Product Type: Digital DC Output Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 80g

  • Dimensions: 46 mm x 94 mm x 53 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

The 1794-OB16 is a high-density digital output module functioning within the FLEX I/O distributed architecture. This hardware component interfaces directly with standard terminal bases to supply twenty-four volt direct current (24V DC) sourcing signals to various field actuators, indicators, and interposing relays. By converting electronic logic commands from a central processing unit into physical switching operations, the device enables modular extension of control topologies away from the main chassis over industrial networks such as EtherNet/IP, ControlNet, or DeviceNet through the addition of an appropriate network adapter.

This module houses sixteen independent, non-isolated output channels configured in a sourcing topology, drawing operational current directly from an external power bus via the terminal base assembly. The 1794-OB16 features internal diagnostic indicators that provide local troubleshooting data to electrical maintenance teams, streamlining verification during line installation and preventive upkeep within continuous process plants, material handling facilities, and automotive manufacturing lines.

Features

  • Sixteen discrete output points arranged in a compact sourcing arrangement.
  • Direct insertion into compatible terminal base units for fast, toolless hot-swapping during active operations.
  • Individual light-emitting diode indicators mapping the status of each discrete channel for fast diagnostics.
  • Flexible system engineering through native compatibility with diverse communication adapters.
  • Solid-state switching mechanics eliminating physical contact wear for expanded life cycles.

Applications

  • Solvent pump and pneumatic valve actuation systems.
  • Control panel indication lights and stacked signaling towers.
  • Interposing relay driver circuits inside power distribution boards.
  • Packaging line sorting gate activation switches.

Technical Specifications

Parameter Specification
Manufacturer Rockwell Automation / Allen-Bradley
Brand FLEX I/O
Part Number 1794-OB16
Module Type Digital Sourcing Output Module
Number of Outputs 16, Non-isolated
Nominal On-State Voltage 24V DC
Operating Voltage Range 10V DC to 31.2V DC
On-State Current Rating 0.5 A per channel maximum (8.0 A per module maximum)
Surge Current Limit 2 A for 50 ms, repeatable every 2 s
Power Dissipation 4.3 W maximum at 31.2V DC
FlexBus Current Draw 80 mA at 5V DC
Off-State Leakage Current 0.5 mA maximum
Operating Temperature 0 to 55 degC
Storage Temperature -40 to 85 degC
Relative Humidity 5% to 95% non-condensing
Country of Origin USA
Approximate Weight 0.08 kg
Approximate Dimensions 46 mm x 94 mm x 53 mm

Connections/Interfaces

Terminal Base Pin (Typical 1794-TB3) Function
Pin 0 to Pin 15 Output Channels 0 through 15
V 24V DC Sourcing Power Supply Input
COM DC Common Return Path

Installation Guidelines

DIN Rail Installation

Hook the top of the unit under the upper edge of the standard 35 mm DIN rail. Rotate the chassis downward until the integrated locking mechanism engages securely with the lower lip of the tracking rail.

Terminal Base Compatibility

Align the module side grooves with the guide rails on the pre-installed terminal base unit, such as a 1794-TB2 or 1794-TB3. Push down firmly until the module is fully seated and the retention latch snaps into place.

Cable Routing

Keep all discrete output wire channels physically separated from high-voltage AC lines and motor drive supply cords. Utilize bundled wiring trays to reduce cross-talk and ambient electromagnetic disturbance across the signal conductors.

Power Termination

Verify that external 24V DC power leads are securely screwed into the corresponding bus links on the terminal base block. Disconnect the primary line breakers before running terminal terminations to prevent unintended component short-circuiting.

FAQ

What is the switching orientation of this specific module?

The module operates using a sourcing design, delivering 24V DC from the supply bus to the wired load device when an output point transitions to the active high state.

Does this device feature individual isolation barriers between channels?

No, the sixteen points are non-isolated and utilize a shared internal power and common reference rail across the module circuit board.

Can a damaged unit be swapped while the terminal base remains powered?

Yes, the hardware structure allows for removal and replacement under power, but field-side actuator power should be isolated to prevent accidental equipment motion.

What terminal bases are recommended for installation?

The unit fits onto standard modules including the 1794-TB2, 1794-TB3, 1794-TBN, and 1794-TB3S options depending on the required wiring termination layout.

What do the front panel yellow LED lights represent?

Each numbered indicator corresponds to an output point and illuminates when that channel receives a logical command to turn on.

Is there built-in overcurrent or short-circuit protection for each channel?

The module relies on external fusing or the electrical characteristics of the sourcing circuitry to prevent overload damage if an external short occurs.

What is the current capacity per point if all channels are active?

Each channel can supply up to 0.5 A continuously, provided the total cumulative module current draw does not exceed the maximum aggregate limit of 8.0 A.

How does the module communicate back to a main ControlLogix controller?

It transfers data across the backplane to a network adapter module installed on the leftmost side of the local DIN rail cluster.

What is the minimum operating voltage required for stable output switching?

The reliable electrical operating window requires a minimum input potential of 10V DC to drive the internal solid-state output circuits.

Does this purchase include the terminal block base unit?

No, this part number represents the electronic plug-in module only, requiring the terminal base to be sourced separately.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Szürkésfehér
Country of origin
Egyesült Államok
Power source
DC áram

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...