1 / 1

B&R X20AI1744 X20 System Analog Input Module

B&R X20AI1744 X20 System Analog Input Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20AI1744

  • Country of origin:Egyesült Államok

  • Product Type: Analog Inputs

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Technical Description and Application

The X20AI1744 (X20AI1744) is an industrial-grade analog input module designed for the high-density B&R X20 System automation platform. Engineered to deliver stable, high-resolution signal monitoring in challenging process environments—such as oil gas refineries, automated chemical blending plants, and high-speed manufacturing lines—this module interfaces with standard industrial analog field sensors. It accurately processes continuous physical variables (including pressure, flow rates, level measurements, and mechanical positioning) and translates them into deterministic digital data streams for the primary CPU. Implementing this module within your decentralized I/O matrix optimizes closed-loop control precision, minimizes signal propagation jitter, and shields the core system logic from unexpected field-side voltage anomalies.

Operational Architecture and Interface Logic

This I/O component incorporates advanced analog-to-digital conversion circuitry to ensure precise signal reproduction across all active channels. Built with individual channel filtering parameters managed via software, the module eliminates high-frequency electrical noise generated by adjacent variable frequency drives (VFDs) and heavy inductive switching equipment. The internal electronics draw a minimal power budget from the underlying X20 backplane bus, preserving thermal efficiency across the entire local node stack. The hardware includes real-time diagnostic monitoring, allowing the unit to continuously evaluate signal boundary thresholds and communicate open-circuit or over-range states directly to the central processing architecture.

Technical Performance Metrics

Operational Parameter Engineered Specification
Model X20AI1744
Brand B&R (Bernecker + Rainer)
Module Category X20 System Analog Input
Signal Input Type Continuous Analog Signals (Voltage/Current)
A/D Conversion Resolution High-precision industrial resolution
Diagnostic Capabilities Channel-specific error monitoring via bus software
Isolation Barrier Optocoupler isolation between bus and I/O channels
Status Display Integrated LED operational indicators
Operating Humidity Limits 5 to 95% non-condensing
Storage Temperature Profile -25 to 55 deg C
Country of Origin Austria
Net Device Weight Approx. 0.10 kg
Gross Shipping Weight 2.0 kg (Enclosed in multi-layer protective packaging)

System Integration FAQ

How does the X20AI1744 report a sensor wire failure or out-of-bounds signal?

When a field sensor loop encounters a broken wire or drops below standard electrical thresholds (such as falling below 3.6 mA on a 4-20 mA loop), the module sets a diagnostic error bit in its internal status byte. This data is transmitted across the X20 bus to B&R Automation Studio, allowing programmed alarms to execute immediately.

Can this analog input module handle both voltage and current signals simultaneously?

The specific channel configurations, including electrical signal ranges and scaling factors, are set within the hardware tree of B&R Automation Studio. Ensure your input signal types match the configuration parameters defined for each distinct terminal path.

Is external shielding required for the analog input sensor lines?

Yes. Analog signals operate at low signal levels and are susceptible to EMI. You must use twisted-pair shielded instrumentation cables and ground the shield properly at the enclosure entry point to maintain accuracy.


Field Commissioning and Installation Protocols

  • Shield Termination and Noise Suppression: To avoid ground loops that skew analog accuracy, connect the cable shield braid to the functional earth ground at only one single point, preferably at the grounded DIN rail of the I/O enclosure. Keep unshielded wire sections as short as possible when routing conductors into the terminal blocks.

  • Module Seating and Retaining Alignment: Mount the X20AI1744 vertically into its designated X20 terminal base module. Press firmly until the top and bottom plastic locking tabs snap into place with a distinct click, confirming that the internal backplane pins have achieved a low-resistance connection with the system bus.

  • Enclosure Thermal Management: While the module operates with low power consumption, clustering multiple analog units tightly within a sealed enclosure requires proper convection airflow. Maintain standard clearance zones above and below the X20 rail assembly to ensure ambient conditions do not exceed safe operational bounds.

 

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Szürkésfehér
Country of origin
Egyesült Államok
Power source
DC áram

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...