The X20SO6300 (X20SO6300) is a specialized safe digital output module within the B&R X20 system, designed to meet the most stringent functional safety requirements in industrial automation. This module features 6 safe type B1 digital outputs, providing a reliable interface for safety-related actuators such as contactors, safety valves, and light curtain muting circuits. With an ultra-fast OSSD (Output Signal Switching Device) test pulse of less than 10 microseconds, it ensures continuous diagnostic monitoring without interrupting the load. Engineered for critical safety loops in high-risk environments—including robotic workstations, press control systems, and chemical processing plants—the X20SO6300 provides the essential hardware layer for achieving SIL 3 or PLe safety ratings when integrated into a SafeLOGIC control network.

Technical Configuration

The X20SO6300 utilizes an advanced FET output architecture with dual positive switching (type B1) to ensure fail-safe performance. A key technical feature is that the output level is readable by the system, allowing for real-time feedback and cross-checking of the actual output state against the commanded logic. The module operates on a nominal 24 VDC supply with a wide tolerance range of -15% to +20%, maintaining stability during industrial power fluctuations. To prevent damage during installation or maintenance, the unit includes integrated reverse polarity protection. Each of the 6 channels is optimized for low-power safety components, providing a nominal output current of 0.2 A per channel.

Technical Specifications

Feature Specification
Model X20SO6300
Brand B&R (Bernecker + Rainer)
Module Type Safe Digital Output Module
Number of Outputs 6 Safe Outputs (Type B1)
Nominal Voltage 24 VDC
Voltage Range 20.4 to 28.8 VDC
Nominal Output Current 0.2 A per channel
OSSD Test Pulse < 10 microseconds
Output Type FET, Positive Switching
Humidity (Operation) 5 to 95%, non-condensing
Dimensions Standard X20 Module Width
Shipping Weight 2.0 kg
Protection Reverse polarity protection

Technical FAQs

What is the significance of the OSSD <10 microsecond specification?

The OSSD pulses are extremely short diagnostic tests that check for short circuits and cross-faults in the wiring. Because these pulses are less than 10 microseconds, they are fast enough that the connected safety actuators (like relays or solenoids) do not physically react or drop out, ensuring "dark test" capability during operation.

Can the status of the safe outputs be monitored by the non-safety PLC?

Yes, the X20SO6300 allows the output level to be readable. While the safety logic controls the output via the SafeLOGIC controller, the status information can be bridged to the standard PLC for diagnostic visualization and HMI reporting.

What happens if the power supply polarity is reversed during installation?

The module is equipped with integrated reverse polarity protection. This prevents the internal safety electronics from being destroyed if the 24 VDC and ground wires are accidentally swapped, though the module will not operate until the wiring is corrected.


Engineering & Installation Guide

  • Load Characterization: This module is rated for 0.2 A per channel. It is specifically designed for high-impedance safety inputs or small safety relays. If you are driving larger inductive loads, ensure that the inrush current does not exceed the FET limitations, and always utilize external suppression diodes if the actuator does not have integrated flyback protection.

  • Safety Network Integration: The X20SO6300 must be used in conjunction with a B&R SafeLOGIC controller (such as the X20SL series). Ensure that the safety address is correctly set via the hex switches or software configuration to match your project’s safety map, as a mismatch will prevent the Safety Release from occurring.

  • Environmental Management: In environments with high humidity (up to 95%), ensure that the control cabinet is properly sealed and utilize climate control if condensation is a risk. While the module is rated for non-condensing operation, moisture on the terminal blocks can lead to leakage currents that may trigger "cross-fault" safety errors.

 

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Sárga
Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...