Integrating industrial I/O signals directly into Ethernet networks, the BECKHOFF BK9100 functions as a high-performance Ethernet TCP/IP bus coupler designed for modular Bus Terminal configurations. This interface module bridges the fieldbus-independent K-bus system with standard Ethernet networks, permitting efficient decentralized automation architectures.

The unit features an integrated 3-port switch (configured as a 2-channel switch and one internal port), facilitating line topology and star topology physical wiring without requiring external network switches. Communication capabilities include multi-protocol support, enabling seamless integration within TwinCAT ADS systems, Modbus TCP networks, and Beckhoff real-time Ethernet environments. Configuration and diagnostics are conveniently handled via the KS2000 software interface.

Features

  • Dual-Channel Switch: Equipped with 2 x RJ45 ports for cost-efficient line topology cascading of up to 20 BK9100 units.
  • Flexible Expansion: Connects up to 64 Bus Terminals directly, with scalability up to 255 terminals using a K-bus extension.
  • Multi-Protocol Support: Compatible with TwinCAT ADS, Modbus TCP, and Beckhoff Real-Time Ethernet protocols.
  • Auto-Negotiation: Detects transmission speeds of 10 or 100 Mbit/s automatically.
  • Reliable Isolation: Features 500 V electrical isolation between power contacts, supply voltage, and the fieldbus network.

Applications

  • Process control and industrial automation networks
  • Decentralized data acquisition systems
  • Factory floor I/O expansion in line and star topologies
  • Water and wastewater management systems
  • Material handling and building automation infrastructure

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model BK9100
Number of Bus Terminals 64 (up to 255 with K-bus extension)
Max. Number of Fieldbus Bytes 512 bytes input / 512 bytes output
Digital Peripheral Signals 512 inputs / 512 outputs
Analog Peripheral Signals 128 inputs / 128 outputs
Configuration Capability Via KS2000 software
Protocols TwinCAT ADS, Modbus TCP, Beckhoff real-time Ethernet
Data Transfer Rates 10/100 Mbit/s (automatic detection)
Bus Interface 2 x RJ45 (2-channel switch)
Data Transfer Medium 4 x 2 twisted pair copper cable; Category 3 (10 Mbit/s), Category 5 (100 Mbit/s)
Power Supply 24 V DC (-15% / +20%)
Input Current 70 mA + (total K-bus current)/4, 500 mA maximum
Starting Current 2.5 x continuous current
Recommended Fuse Less than or equal to 10 A
Current Supply K-Bus 1750 mA
Power Contacts Max. 24 V DC / Max. 10 A
Electrical Isolation 500 V (power contact / supply voltage / fieldbus)
Operating Temperature -25 to +60 Celsius
Storage Temperature -40 to +85 Celsius
Relative Humidity 95%, no condensation
Vibration and Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Weight Approx. 170 g

Installation Guidelines

  • Mounting: Designed for standard 35 mm DIN rail installation conforming to EN 60715. Ensure correct seating and secure snapping mechanism alignment.
  • Wiring: Use Category 5 shielded twisted-pair (STP) copper cables for 100 Mbit/s operation to ensure robust immunity against electromagnetic interference.
  • Grounding: Connect the DIN rail to a low-impedance protective earth ground. Ensure shield continuity across all RJ45 connections.
  • Network Cascading: In line topologies, the maximum physical distance between stations is 100 m. Up to 20 BK9100 units can be cascaded, with a maximum total line length of 2 km.

Compliance and Certifications

  • CE: Yes
  • UL: Yes
  • DNV GL: Marine Certified
  • ATEX Ex-Marking: II 3 G Ex ec IIC T4 Gc
  • IECEx Ex-Marking: Ex ec IIC T4 Gc

How many Bus Terminals can be connected to the Beckhoff BK9100?

The BK9100 can connect up to 64 Bus Terminals directly. With a K-bus extension, the network can be expanded to support up to 255 Bus Terminals.

Which communication protocols does the BK9100 support?

The BK9100 supports TwinCAT ADS, Modbus TCP, and Beckhoff real-time Ethernet protocols.

Does the BK9100 support daisy-chain topology?

Yes, because it includes an integrated 2-channel switch (2 x RJ45 ports), you can cascade up to 20 BK9100 units in a line topology without requiring external switches.

What is the maximum current supply capacity for the internal K-bus?

The BK9100 delivers a maximum current supply of 1750 mA to the internal K-bus system.

What cables are recommended for connection to the BK9100?

A Category 3 (10 Mbit/s) or Category 5 (100 Mbit/s) 4 x 2 twisted-pair copper cable is recommended for reliable data transfer.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Németország

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...