1 / 1

Beckhoff C9900-E871 CP6xxx CP7xxx Push-button Extension

Beckhoff C9900-E871 CP6xxx CP7xxx Push-button Extension

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: C9900-E871

  • Country of origin:Németország

  • Product Type: HMI Push-Button Extensions

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: drawings with dimensions of the push-button e x tensions as AutoCAD DXF file

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Designed for direct integration onto the right side of Beckhoff CP6x32-00xx and CP7x32-00xx Control Panels, the Beckhoff C9900-E871 provides an auxiliary physical interface expansion for 15-inch HMI displays operating without an integrated keyboard. This rugged operator panel extension interfaces critical mechanical controls directly to the host control system, bridging physical actuation with digital bus communication. By incorporating industrial-grade switches and a dedicated emergency stop, it enhances spatial efficiency and operating convenience directly at the machine face.

Features

  • 18 Illuminated Push-Buttons: Equipped with high-durability Siemens Signum square keys (30 x 30 mm) containing integrated signal lamps.
  • Integrated Emergency Stop: Features one heavy-duty Siemens Signum emergency stop button designed for direct safety circuit integration.
  • Dual-Signal Routing: Transmits all push-button inputs via CP-Link or USB connection as a primary normally-open (NO) contact, with an independent secondary NO contact mapped directly to a terminal block.
  • Bus-Driven Indicator Lamps: Coordinates all signal lamp illumination strictly through CP-Link or USB communication protocols.
  • Customizable Legend Strips: Supports insertable label caps for rapid, application-specific functional engraving or text marking.

Applications

  • Automotive manufacturing assembly and machining cell control stations.
  • CNC machine tools and heavy industrial material handling systems.
  • Process control setups utilizing 15-inch fanless industrial PCs and HMI panels.
  • Safety-critical physical override environments demanding hardwired E-stop circuits.

Technical Specifications Table

Specification Parameter Value / Detail
Manufacturer Beckhoff Automation
Model Number C9900-E871
HMI Panel Compatibility CP6x32-00xx and CP7x32-00xx Series (15-inch without keyboard)
Mounting Location Right side of the HMI unit
Push-Button Element Type 18 x Siemens Signum Square (30 x 30 mm)
Emergency Stop Type 1 x Siemens Signum twist-to-release (direct-wireable)
Communication Interface USB or CP-Link (model dependent)
Contact Configuration (Buttons) 1st NO via USB/CP-Link; 2nd NO via terminal strip
Indicator Lamp Control Over bus interface (USB or CP-Link) only
Lifecycle Phase Service Phase (Legacy support and spare parts availability)
Shipping Weight (Calculated) 5.00 kg (11.02 lbs)

Connections and Interfaces

Terminal / Port Functional Assignment & Signal Type
USB / CP-Link Interface Primary communication bus interface; handles 1st NO contact inputs and drives active signal lamp outputs.
Direct Terminal Strip Access point for secondary isolated NO dry contacts for all 18 push-buttons; used for localized hardware interlocks.
Emergency Stop Terminals Hardwired NC contacts routed independently of the USB/CP-Link bus to interface directly with safety evaluation relays.

Empirical Engineering Insights

Alternative Models & Compatibility

The C9900-E871 is structurally sized to physically align only with 15-inch variants of the CP6x32 and CP7x32 control panels. If you are retrofitting a system with a different display size, this extension block will not mate correctly with the chassis mountings. Verify that the matching driver software or TwinCAT system manager configurations are set to recognize the USB-based keyboard emulation profile utilized by this extension.

Application Pitfalls & Engineering Notes

A common site failure involves trying to wire the 24V indicator lamps directly through the terminal strip. Note that the signal lamps are exclusively controlled via the digital USB or CP-Link connection. If your system application loses USB communication, the indicator lamps will remain dark, regardless of local direct terminal status. Ensure your PLC logic accounts for this behavior in high-duty environments.

Commissioning & Wiring Tips

To maintain compliance with Category 3 or 4 safety standards, never route the emergency stop signal through the USB/CP-Link bus. The integrated emergency stop button must be wired directly to an approved safety controller or monitoring relay utilizing the physical auxiliary contacts provided on the back of the extension assembly.

Installation Guidelines

CRITICAL WARNING:

Before starting mechanical mounting or electrical integration, completely isolate the 24V DC supply feeding the HMI Panel PC. Confirm the panel is fully de-energized to prevent short-circuits across the USB interface or secondary hardwired contacts during installation.

1

Align the C9900-E871 extension housing with the structural mounting points on the right-hand bezel of the CP6xxx/CP7xxx panel.

2

Secure the mechanical linkage using the supplied fasteners, taking care to maintain the target IP ingress protection rating at the joint interface.

3

Route and connect the internal USB or CP-Link wiring harness directly into the designated ports inside the main panel computer housing.

4

Interface the dedicated emergency stop contacts and hardwired push-button terminals into the local control cabinets, matching system wiring diagrams.

Can the push-button labels on the C9900-E871 be customized in the field?

Yes. The push-button caps on the C9900-E871 allow for individual insertion of printed label strips, allowing operators to mark functions according to system-specific requirements.

How are the push-button signals processed by the Beckhoff controller?

The buttons utilize a dual-contact scheme. The primary contact is transmitted digitally via USB or CP-Link, while a secondary normally-open contact is routed to a physical terminal block on the rear for direct PLC input cards or hardwired loops.

Is it possible to light up the key indicator lamps using external 24V digital outputs?

No. The indicator signal lamps are driven exclusively via the USB or CP-Link connection. There are no physical terminal block connection points to power the lamps directly.

What display sizes are compatible with this mechanical extension?

The C9900-E871 is engineered and dimensioned to physically mate with 15-inch Beckhoff CP6x32-00xx and CP7x32-00xx Control Panels and Panel PCs.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Németország

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...