1 / 1

BECKHOFF KS4004 KS Series Bus Terminal

BECKHOFF KS4004 KS Series Bus Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KS4004

  • Country of origin:Németország

  • Product Type: Bus Terminals

  • Payment: T/T, Western Union

  • Weight: 85g

  • Dimensions: 6.8 cm x 1.2 cm x 10.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

The KS4004 analog output terminal is designed to generate highly accurate analog signals within the range of 0 to 10 V. Engineered as part of the Beckhoff KS series, this 4-channel module features a pluggable wiring level that permits swift replacement during maintenance without disconnecting active field wiring. The terminal processes electrical signals with a resolution of 12 bits and transfers them, electrically isolated, to the process level. The power required to operate the module is drawn directly from the K-bus, eliminating the need for separate external power contacts.

This single-ended output terminal is optimized for compact control cabinets where high-density analog output signals and quick-disassembly capabilities are critical. With built-in short-circuit protection and an exceptionally low output error margin, the KS4004 guarantees stable command signal delivery to actuator drives, control valves, and other analog-driven field devices in complex process environments.

Features

  • Four analog output channels with a 0 to 10 V signal range.
  • Pluggable connection level for easy installation and tool-free module swap-outs.
  • Internal power supply driven directly via the Beckhoff K-bus interface.
  • Short-circuit proof outputs designed to handle loads greater than 5 kOhm.
  • High-accuracy performance with a relative output error of less than +/-0.1 % of the full-scale value.
  • No address or hardware configuration required prior to deployment.

Applications

  • Industrial positioning systems and actuator control loops.
  • Variable frequency drive (VFD) speed reference signaling.
  • HVAC dampers and climate control system modulation.
  • Standard machine building and process plant automation.

Technical Specifications

ManufacturerPart Number / ModelTechnologyNumber of OutputsPower SupplySignal VoltageLoadOutput ErrorResolutionConversion TimeElectrical IsolationCurrent Consumption K-BusCurrent Consumption Power ContactsBit Width in Process ImageOperating TemperatureStorage TemperatureRelative HumidityVibration and Shock ResistanceEMC Immunity and EmissionProtection RatingDesignMaterialInstallationDimensions (L x W x H)Weight
BECKHOFF
KS4004
Single-ended
4
Via the K-bus
0 to 10 V
> 5 kOhm (short-circuit proof)
< +/-0.1 % (relative to end value)
12 bit
Approx. 2 ms
500 V (K-bus/signal voltage)
Typ. 85 mA
None (no power contacts)
Output: 4 x 16 bit data (optional 4 x 8 bit control/status)
0 to +55 degC
-25 to +85 degC
95 %, no condensation
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4
IP20 (variable installation position)
Terminal housing with pluggable wiring level
Polycarbonate
35 mm DIN rail (conforming to EN 60715) with lock
6.8 cm x 1.2 cm x 10.0 cm
0.085 kg

Connections and Interfaces

Wiring MethodSolid Wire Cross-SectionStranded Wire Cross-SectionFine-Wire Cross-SectionStripping Length
Connection Property Specification
Spring actuation by screwdriver
0.08 to 1.5 mm² (AWG 28 to 16)
0.08 to 1.5 mm² (AWG 28 to 16)
0.14 to 1.5 mm² (AWG 26 to 16)
9 to 10 mm

Installation Guidelines

  • Mount the module vertically or horizontally on a standard 35 mm DIN rail conforming to EN 60715. Ensure the locking slide mechanism snaps securely into place.
  • To prevent electromagnetic interference on sensitive 0-10 V analog lines, use shielded cables and connect the shield to a low-resistance ground terminal near the entry point of the control panel.
  • Ensure that no field wiring is connected when plugging or unplugging the terminal wiring level to avoid transient electrical spikes.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc

What is the primary difference between Beckhoff KS and KL series terminals?

The KS series terminals (such as the KS4004) feature a pluggable connection level that can be detached from the housing. This allows the terminal electronics to be replaced without disconnecting the pre-wired terminal blocks.

Does the KS4004 require an external power supply connection?

No, the KS4004 does not use external power contacts. It is powered internally via the standard Beckhoff K-bus, consuming typically 85 mA.

What is the output voltage and channel capability of the KS4004?

The KS4004 provides 4 analog output channels, each capable of outputting a 0 to 10 V signal with 12-bit resolution.

Is the analog output protected against short circuits?

Yes, the analog outputs on the KS4004 are short-circuit proof for loads greater than 5 kOhm.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Németország

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...