1 / 1

Bently Nevada 177230-01-01-05 Seismic Transmitter

Bently Nevada 177230-01-01-05 Seismic Transmitter

Only 5 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 177230-01-01-05

  • Country of origin:Egyesült Államok

  • Product Type: Seismic Transmitter

  • Payment: T/T, Western Union

  • Weight: 131g

  • Dimensions: 66.0 mm x 25.4 mm x 25.4 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

The Bently Nevada 177230-01-01-05 is a loop-powered seismic transmitter designed for machinery condition monitoring. It integrates directly into programmable logic controllers (PLCs), DCS, and SCADA systems that provide internal loop power. The 177230-01-01-05 processes vibration measurements and outputs a primary 4 to 20 mA current loop representing velocity vibration, along with a secondary raw dynamic voltage output representing acceleration for detailed signal analysis.

Features

  • Interfaces directly with PLCs, DCS, and SCADA control systems.
  • Provides a primary 4 to 20 mA loop-powered velocity output and a secondary raw dynamic voltage output.
  • Requires no field configuration or adjustments.
  • Features a hermetically sealed 316L stainless steel case for demanding environments.
  • Includes self-test capabilities and a protected interface.

Applications

  • Machinery asset condition monitoring
  • Overall plant vibration measurement
  • Balance-of-plant rotating machinery protection
  • Integration into PLC, DCS, and SCADA control loops

Ordering Information

Option / Ordering Code Description
177230-AA-BB-CC Seismic Transmitter
AA: Measurement Range 01 = 0 to 25.4 mm/s (0 to 1.0 in/s)
BB: Frequency 01 = 10 Hz to 1 kHz (600 to 60 kcps) rms
CC: Approvals 05 = Multiple Approvals (CSA/NRTL/C, ATEX/IECEx)

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Model 177230-01-01-05
Product Type Seismic Transmitter
Main Loop Sensitivity (Signal One) 0.0 to 25.4 mm/s (0 to 1.0 in/s) +/- 10% FS, broadband rms
Output Format (Pin A ref Pin B) 4 to 20 mA current loop, velocity vibration
Dynamic Signal Sensitivity (Signal Two) 10.2 mV/m/s2 (100 mV/g) +/- 20%
Output Format (Pin C ref Pin B) Voltage, acceleration vibration, unbuffered
Dynamic Signal Frequency Response 2.5 Hz to 10 kHz (150 cpm to 600 kcpm) +/- 10%
Main Loop Frequency Response 10 Hz to 1 kHz (600 cpm to 60 kcpm) +/- 10%
Excitation Voltage 12 to 30 Vdc (current limited to 40 mA)
Settling Time Less than 15 seconds within 2% of final value
Linearity +/- 1%
Output Bias (ref Pin B) 2.5 V +/- 0.1 V
Full Scale Range 147 m/s2 (15 g's) peak
Mounted Resonant Frequency Greater than 12 kHz
Transverse Sensitivity Less than 5% of sensitivity
Sensing Element Type Ceramic / Shear
Operating Temperature Range -40 degC to +85 degC (-40 degF to +185 degF)
Electrical Isolation Greater than 10^8 ohms
Isolation Breakdown Voltage 600 Vrms with less than 1 mA leakage current
Sensor Seal Hermetically sealed
Relative Humidity To 100% non-submerged
Case Material 316L stainless steel
Connector Type 3-pin MIL-C-5015, 316L stainless steel
Mounting Hole / Threads 1/4-28 UNF; supplied with M6x1, M8x1.25, and 1/4-28 UNF adapters
Mounting Torque 4 to 7 N-m (35.4 to 62.0 in-lbf)
Transmitter Weight 131 g (4.62 oz) typical
Dimensions 25.4 mm (1.00 in) Diameter x 66.0 mm (2.60 in) Height

Connections/Interfaces

Connector Pin Function
Pin A 4-20 mA Positive Loop (Positive with reference to Pin B)
Pin B 4-20 mA Negative Loop / Return for Dynamic Signal
Pin C Dynamic Signal in voltage, unbuffered (Referenced to Pin B)

Installation Guidelines

  • Mounting Method: Mount directly to the machine surface using the provided stud adapters and torque to 4 to 7 N-m.
  • Magnetic Base Precaution: If using a magnetic base, roll the base onto the machine surface. Avoid snapping the unit onto the machine, as sudden impact can generate large voltage spikes that may damage internal electronics.
  • Grounding and Signal Isolation: Ensure the dynamic signal return (Pin B) is isolated from external grounds. Grounding this terminal shorts the 4 to 20 mA current loop, resulting in signal loss.

Compliance and Certifications

  • FCC: Complies with Part 15 of FCC Rules.
  • EMC: EMC Directive 2014/30/EU.
  • RoHS: RoHS Directive 2011/65/EU.
  • CSA/NRTL/C: Class I, Div 1, Groups A, B, C, D; Class II, Div 1, Groups E, F, G; Class III, Div 1 (Ex ia IIC T4 / AEx ia IIC T4); Class I, Div 2, Groups A, B, C, D (Ex nL IIC T4 / AEx nA IIC T4).
  • ATEX/IECEx: II 1 G Ex ia IIC T4 Ga / II 3 G Ex na IIC T4 Gc (Ta = -40 degC to +80 degC).
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 177230-01-01-05 Seismic Transmitter

What power supply is required to operate the device?

The device operates on a 12 to 30 Vdc loop power excitation voltage, current limited to 40 mA, typically supplied directly by host PLCs or DCS controllers.

What outputs are provided by the unit?

The device provides a primary 4 to 20 mA loop-powered velocity output on Pin A and a secondary unbuffered dynamic acceleration voltage output on Pin C.

What mounting precaution should be followed when using a magnetic base?

The device must be rolled onto the machine surface rather than snapped into place, preventing mechanical shocks that can produce high voltage spikes and damage internal electronics.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Ezüst
Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.

What It Really Takes to Learn Industrial Automation in 2026

Learning industrial automation now means mastering PLCs, networks, and protection systems—not just robots. This guide maps skills, pitfalls, and career paths for engineers entering control-heavy...

OpenVMS Alphán futó Bailey INFI 90 Symphony HMI-k korszerűsítése

Gyakorlati útmutató az OpenVMS Alpha rendszeren futó, elöregedett Bailey Symphony kezelőállomások lecseréléséhez. Összehasonlítja az Alpha-emulációt, az OpenVMS x86-ra történő migrációt, az...

Miért elengedhetetlenek a karbantartási adatok az ipari megbízhatósághoz

A karbantartási adatok összekapcsolják a munkamegrendeléseket, az érzékelőjelek adatait, az eszközelőzményeket, a költségeket és a technikusok tudását. Megfelelő használat mellett javítják a...

A folyadékalapú erőrendszerek kiváltására tervezett elektromos működtetők: gyakorlati útmutató az ipari automatizáláshoz

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos aktuátorok, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést a hagyományos pneumatikus és hidraulikus rendszerek...

Matematikai műveletek OpenPLC használatával ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC-rendszerek olyan alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban....