1 / 3

Bently Nevada 24765-01-00 Case Expansion Transducer System

Bently Nevada 24765-01-00 Case Expansion Transducer System

Only 7 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 24765-01-00

  • Country of origin:Egyesült Államok

  • Product Type: Case Expansion Transducer Systems

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1740g

  • Dimensions: 35 x 15 x 15 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Designed for critical turbomachinery asset monitoring, the Bently Nevada 24765-01-00 Case Expansion Transducer System measures the relative thermal growth of machine housings during startup, operation, and shutdown cycles. This system provides vital mechanical growth data to prevent structural binding and alignment damage on large steam turbines, gas turbines, and industrial machinery. By utilizing a high-precision Linear Variable Differential Transformer (LVDT) mechanism, the device translates linear physical displacement into a proportional electrical signal compatible with continuous machinery protection systems.

Features

  • Contactless LVDT design prevents mechanical wear and preserves long-term calibration accuracy.
  • Heavy-duty, dual-spring-loaded plunger assembly maintains continuous physical contact with the machine casing.
  • Hermetically sealed sensing elements ensure reliable operation in high-humidity, steam-exposed, and dusty environments.
  • Direct compatibility with industry-standard Bently Nevada 3500/45 Position Monitors.
  • Robust mounting structure engineered to withstand persistent high-amplitude industrial vibrations.

Applications

  • Steam turbine casing expansion and thermal growth monitoring.
  • Gas turbine structural casing displacement tracking.
  • Large industrial process compressor thermal expansion measurement.
  • Structural shifting and alignment monitoring in utility-grade power generation equipment.

Technical Specifications

Parameter Specification Value
Manufacturer Bently Nevada
Model Number 24765-01-00
Sensor Type Linear Variable Differential Transformer (LVDT)
Measurement Range 1.0 in (25.4 mm) nominal
Excitation Frequency 3 kHz nominal
Operating Temperature Range -34 to 149 degC (-30 to 300 degF)
Linearity Plus or minus 0.50% of full scale range
Mounting Configuration Spring-loaded plunger with foot contact
Country of Origin United States
Shipping Weight (Calculated) 3.2 kg (7.0 lbs)
Package Dimensions (Calculated) 35 x 15 x 15 cm

Connections and Interfaces

Terminal / Connection Pin Function / Circuit Assignment
Excitation High (+) AC excitation voltage input positive
Excitation Low (-) AC excitation voltage input return
Signal Out High (+) LVDT secondary output voltage positive
Signal Out Low (-) LVDT secondary output voltage return
Shield Instrument ground connection / cable shield drain

Empirical Engineering Insights

Alternative Models & Compatibility

The 24765-01-00 integrates with standard 3500/45 position monitor channels configured specifically for LVDT sensors. Ensure the monitor firmware supports the selected range option (-01, typically 1.0 inch). If upgrading an older mechanical dial-indicator casing setup, mechanical modification of the target foot plate on the machine foundation may be required to maintain parallel alignment.

Application Pitfalls & Engineering Notes

Mechanical binding is the most common failure mode for case expansion systems. If the mounting bracket flexes or is installed at an angle relative to the casing's actual direction of movement, the internal plunger can bind within its sleeve. Misalignments of more than 2 degrees can lead to measurement hysteresis and eventual shaft seizure during sudden thermal transitions.

Commissioning & Wiring Tips

Prior to final installation, use a physical calibration block to manually cycle the LVDT core and verify that the 3500 rack displays correct, linear voltage responses. Ensure that shielded, twisted-pair cable is used and that the shield is only terminated at the monitoring rack end. A floating shield at the sensor end prevents high-frequency ground loops caused by turbine frame grounding differentials.

Installation Guidelines

CRITICAL WARNING: De-energize and lock out all machinery auxiliary power prior to mounting. Turbine casing surfaces can exceed 100 degC during operational transitions. Allow machinery to cool completely to ambient temperatures before attempting mechanical alignment, mounting, or calibration of the case expansion transducer.
1
Verify the mechanical stroke of the transducer plunger is smooth and completely free from physical obstruction prior to mounting.
2
Securely bolt the transducer mounting bracket to the machine foundation, ensuring the plunger is perfectly parallel to the direction of casing thermal growth.
3
Adjust the mechanical pre-load slip joint so the sensor shaft is partially compressed at cold startup conditions, allowing for the maximum predicted extension.
4
Route wiring through high-temperature conduit, ensuring the cable shield is tied to system ground at the monitoring rack only.

What does the 24765-01-00 package represent in terms of range options?

The -01 option code typically designates a nominal linear displacement measurement range of 1.0 inch (25.4 mm), while the -00 code signifies standard mounting without special conduit options.

Which monitoring racks are compatible with the Bently Nevada 24765 series?

The system is fully compatible with Bently Nevada 3500/45 Position Monitors configured for linear variable differential transformer (LVDT) sensor inputs.

How do you prevent measurement errors due to mechanical binding?

Mounting brackets must be structurally rigid and aligned within 2 degrees of the turbine housing's true direction of thermal expansion. Ensure regular inspection of the sliding plunger shaft for physical wear or debris.

Where should the cable shield be terminated for this transducer system?

The shield should be connected to the instrumentation ground only at the 3500 monitoring rack side. Do not ground the shield at the sensor end to avoid ground loop noise.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...