1 / 1

Bently Nevada 9571-02 Standard Interconnect Cable

Bently Nevada 9571-02 Standard Interconnect Cable

Only 6 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 9571-02

  • Country of origin:Egyesült Államok

  • Product Type: Standard Interconnect Cables

  • Payment: T/T, Western Union

  • Weight: 320g

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Engineered to deliver high-integrity signal transmission within critical machinery protection architectures, the Bently Nevada 9571-02 facilitates low-noise connectivity between industrial transducers and monitoring systems. This heavy-duty cable features a 2-conductor twisted, shielded 22 AWG construction that actively minimizes electromagnetic interference (EMI) and cross-talk in harsh electromagnetic environments. Designed with a specialized 2-socket moisture-resistant female connector at one end and rugged terminal lugs at the other, this 2-foot cable ensures a highly secure electrical and mechanical interface for critical vibration monitoring points. It is built specifically for integration with local monitor racks, excluding use with the 21128 Velocity Transducer Housing.

Features

  • High-Noise Rejection: Twisted-pair configuration combined with an integrated shield drain wire isolates fragile transducer signals from plant EMI/RFI.
  • Rugged Termination: Equipped with a molded, moisture-resistant 2-socket female connector for reliable sensor-side sealing.
  • Secure Panel Interfacing: Pre-terminated with high-quality terminal lugs for direct, reliable installation onto barrier strips and monitor backplanes.
  • Precision Mechanics: Optimally sized 22 AWG conductors maintain electrical continuity and mechanical durability under structural vibration.
  • Short-Run Optimization: 2-foot minimum length design prevents excess cable slack, keeping control cabinets organized and free of inductive loops.

Applications

  • Machinery protection system loops (e.g., Bently Nevada 3500 and 1900 series monitors).
  • Prox probes and vibration sensor-to-junction box connections.
  • Balance-of-plant rotating machinery health monitoring.
  • Short-run internal cabinet and local structural transducer routing.

Technical Specifications Table

Parameter Specification Value
Manufacturer Bently Nevada
Part Number / SKU 9571-02
Cable Type Standard Interconnect Cable (2-Conductor Twisted, Shielded)
Conductor Gauge 22 AWG
Cable Length 2 feet (0.6 meters)
Connector End A 2-socket moisture-resistant female connector
Connector End B Terminal Lugs
Country of Origin United States (USA)
Net Physical Weight 0.11 kg (0.24 lbs) (Calculated)
Shipping Weight (Calculated) 2.0 kg (including packaging and protective spooling)

Connections and Interfaces

Connector Pin / Terminal Function / Signal Assignment
Socket Pin A Signal High / Dynamic Signal (+)
Socket Pin B Signal Common / Return (-)
Terminal Lugs Termination points for terminal block connections at monitor panel
Outer Shield / Drain Grounding shield (MUST terminate only at the monitor common ground)

Empirical Engineering Insights

Alternative Models & Compatibility

The 9571-02 interconnect cable is optimized for standard industrial monitor configurations. It is crucial to note that this specific standard cable is not compatible with the Bently Nevada 21128 Velocity Transducer Housing due to diameter clearances and physical connection constraints. If your plant utilizes the 21128 housing, you must source a specialized splash-resistant or armored cable assembly built specifically for that enclosure profile.

Application Pitfalls & Engineering Notes

Because this is a non-armored variant, care must be taken during routing. Avoid routing the 9571-02 directly parallel to high-voltage AC motor lines or variable frequency drive (VFD) output cables. Lack of mechanical armor means this cable should always be housed within dedicated, grounded conduit or cable trays when routed outside of localized, enclosed instrument cabinets to prevent physical shearing or crushing.

Commissioning & Wiring Tips

To ensure the integrity of high-frequency vibration diagnostics, always terminate the cable's shield drain wire at the monitor rack ground. Never ground the shield at both ends; double-grounding creates ground loops that inject 50/60 Hz electrical noise into the signal path, which can lead to false instrumentation trips or corrupted spectral data.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Before starting the installation or termination of the 9571-02 cable, ensure the corresponding monitor panel loop power is completely de-energized. Verify there is no residual energy on adjacent terminal strips. Failure to isolate power paths can lead to short circuits, damage to delicate input card electronics, or personnel injury.

1 Route the interconnect cable from the transducer mounting point to the monitor cabinet, ensuring the bend radius does not fall below 3 inches (76 mm) to prevent internal wire strain.
2 Align the keying of the 2-socket female connector with the transducer plug. Fully insert and thread the coupling collar to compress the moisture-resistant seal. Hand-tighten securely.
3 Connect the terminal lugs at the opposite end to the assigned screw terminal block of the monitor rack. Ensure the shield drain wire is connected cleanly to the instrument Earth terminal and insulated along the rest of its length.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 9571-02 Standard Interconnect Cable

Can the Bently Nevada 9571-02 cable be used inside a 21128 velocity transducer housing?

No. The 9571-02 is strictly not for use with the 21128 Velocity Transducer Housing due to spatial and mechanical design differences.

What is the physical length and gauge of this interconnect cable?

The 9571-02 cable has a length of 2 feet (approximately 0.6 meters) and features 22 AWG twisted, shielded dual conductors.

How should I ground the shield drain wire for the 9571-02 cable?

The shield drain wire should be grounded at the monitor/instrumentation rack end only. Do not ground it at the transducer end, as this creates ground loops that introduce signal noise.

Is the female connector on the 9571-02 weather-sealed?

Yes, the 2-socket female connector is designed with a moisture-resistant seal to prevent fluid ingress at the transducer junction.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...