1 / 1

Bently Nevada 990-04-70-01-CN 990 Series 2-Wire Vibration Transmitter

Bently Nevada 990-04-70-01-CN 990 Series 2-Wire Vibration Transmitter

Only 3 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 990-04-70-01-CN

  • Country of origin:Egyesült Államok

  • Product Type: Vibration Transmitters

  • Payment: T/T, Western Union

  • Weight: 320g

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Engineered for seamless integration into industrial machinery protection systems, the Bently Nevada 990-04-70-01-CN functions as a high-precision, loop-powered sensor interface designed to continuously monitor shaft vibration. This 2-wire transmitter converts the dynamic displacement signal from a proximity probe system into a standard 4-20 mA analog current loop, facilitating direct communication with programmable logic controllers (PLCs), distributed control systems (DCSs), or machine condition monitoring platforms.

Designed for rugged industrial environments, this unit simplifies field wiring by combining the proximitor sensor electronics and transmitter functionality into a single, compact housing. The 990-04-70-01-CN is factory-configured for a 0-4 mils peak-to-peak measurement range, optimized for a 7.0-meter system length, and equipped with quick-install DIN rail mounting clips.

Key Features

  • Integrated Proximitor Design: Merges proximity probe driver circuitry with 4-20 mA transmitter loops to minimize total component count in monitoring panels.
  • Loop-Powered 2-Wire Interface: Reduces wiring costs and installation complexity by utilizing the same pair of conductors for both signal transmission and operating power.
  • Non-Contacting Displacement Measurement: Interfaces with standard eddy current proximity probes to measure dynamic shaft movement without physical contact.
  • Local Buffered Output: Provides a raw dynamic signal via a coaxial connector for diagnostic access and vibration analysis with portable instruments.
  • High Noise Immunity: Robust shielding and isolation prevent electromagnetic interference in high-power motor and turbine environments.

Applications

  • Radial vibration monitoring on centrifugal air and gas compressors.
  • Casing and shaft vibration monitoring of industrial steam and gas turbines.
  • Overhung fan shaft displacement tracking in cooling towers.
  • Continuous condition monitoring of heavy-duty process pumps.
  • Balance-of-plant rotating machinery protection where full rack systems are not required.

Model Suffix Configuration

Suffix Code Option Class Technical Specification
-04 Full-Scale Range 0 to 4 mils pp (0 to 100 micrometers peak-to-peak)
-70 System Length 7.0 meters (23.0 feet) total electrical length
-01 Mounting Hardware 35 mm DIN rail clips pre-installed
-CN Agency Approvals Region-specific safety certifications (China/Asia-Pacific)

Technical Specifications

Manufacturer Bently Nevada
Model Series 990 Vibration Transmitter Series
Full-Scale Input Range 0 to 4 mils peak-to-peak (0 to 100 um pp)
Output Signal Range 4 to 20 mA DC (proportional to full scale)
Operating Voltage 12 to 35 VDC (at the transmitter terminal)
Maximum Loop Resistance RLoop = (VSupply - 12V) / 0.02A ohms
Required Probe Compatibility 3300 XL 8mm proximity probe (or verified equivalent)
Target Calibration Material AISI 4140 steel (standard target configuration)
Operating Temperature Range -35 to +85 Celsius
Storage Temperature Range -40 to +100 Celsius
Country of Origin United States
Shipping Weight (Calculated) 1.5 kg (approx. 3.3 lbs)

Connections and Interfaces

Terminal / Port Label / Standard Marker Function & Circuit Assignment
Pin 1 + / PWR Positive supply voltage connection (4-20 mA Loop +)
Pin 2 - / SIG Signal return connection (4-20 mA Loop -)
Pin 3 SHD Instrumentation shield tie-point (internally isolated from DIN rail)
Coaxial Port BUF Coaxial buffered raw voltage output (approx. 7.87 V/mm scale)

Empirical Engineering Insights

Alternative Models & Compatibility

The 990-04-70-01-CN requires an absolute electrical system length match of 7.0 meters. Do not mix and match with 5.0-meter probe configurations (such as the -50 options) or non-3300 XL systems without recalibrating, as mismatching will cause extreme signal non-linearity and scale factor errors.

Application Pitfalls & Engineering Notes

In highly active electromagnetic environments (e.g., adjacent to variable frequency drives), a common error is allowing the transmitter housing to float electrically. Ensure the 35 mm DIN rail has a direct, low-impedance ground path. Additionally, calculate loop resistance strictly using the minimum expected voltage supply at the cabinet to prevent transmitter dropout at full-scale signal levels (20 mA peaks).

Commissioning & Wiring Tips

When wiring the coaxial sensor extension cable, protect the connector with self-fusing silicone tape or heat-shrink tubing to prevent moisture ingress. Liquid intrusion at the probe-to-extension cable joint alters loop impedance, showing up on the DCS as false high vibration or erratic signal spikes.

Installation Guidelines

CRITICAL SAFETY WARNING

Before installing, removing, or performing maintenance on the transmitter, de-energize all connected electrical loops. Ensure the ambient atmosphere is certified non-hazardous or that proper intrinsically safe barriers are active if deploying this -CN model in classified field areas.

1
Mount the unit firmly onto standard 35 mm symmetric DIN rail (EN 50022) using the integrated -01 mounting clips. Ensure the rail is bonded to a noise-free industrial ground.
2
Connect the 7.0-meter proximity probe coaxial cable system to the integrated coaxial input connector on the transmitter. Hand-tighten the coupling, then snug-tighten to prevent vibration loosening.
3
Route a shielded, twisted-pair instrument cable from the 4-20 mA loop controller to the transmitter terminal block. Terminate +PWR to Pin 1, -SIG to Pin 2, and the cable shield to Pin 3 (SHD).
4
Apply loop power (typically 24 VDC) and verify quiescent loop current draws approximately 4 mA under static (no-vibration, gapped probe) conditions.

Can this transmitter be used with standard 5-meter proximity probe systems?

No. The 990-04-70-01-CN is factory-tuned specifically for a 7.0-meter total system length. Using it with a 5.0-meter probe system will severely compromise scale factor accuracy and signal linearity.

What is the purpose of the BUF coaxial connector on the unit?

The BUF connector provides a buffered raw dynamic voltage output representing the unfiltered probe gap signal, allowing field engineers to connect analyzers for machinery diagnostics without interrupting the 4-20 mA loop.

Does this model include local digital display options?

No. This transmitter is a blind DIN-rail mounted interface intended to feed vibration data directly to PLC/DCS analog input channels for HMI visualization.

What does the -CN suffix indicate for Bently Nevada modules?

The -CN suffix designates country-specific agency approval options, typically verifying certifications required for hazardous area installations in China.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...