1 / 1

Danfoss VLT HVAC Basic Drive FC-101P7K5T4E20H4

Danfoss VLT HVAC Basic Drive FC-101P7K5T4E20H4

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 131L9868

  • Country of origin:Dánia

  • Product Type: FC-101P7K5T4E20H4

  • Payment: T/T, Western Union

  • Weight: 8000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Product Overview

The 131L9868 (131L9868) is a high-efficiency VLT® HVAC Basic Drive FC-101, specifically engineered by Danfoss to meet the rigorous demands of heating, ventilation, and air conditioning systems. Delivering a robust 7.5 kW (10 HP) of power, this frequency converter is the ideal solution for optimizing fan and pump performance in commercial and industrial building automation. By utilizing advanced variable speed control, the FC-101P7K5T4E20H4 significantly reduces energy consumption and mechanical wear on motor-driven systems. Its compact IP20 enclosure is designed for cabinet mounting, providing a cost-effective, "fit-and-forget" solution that enhances system reliability and reduces the total cost of ownership for HVAC infrastructure.

Technical Configuration

The FC-101 series is built on a streamlined hardware platform that prioritizes ease of installation and high energy efficiency. This unit operates on a three-phase 380 - 480 VAC mains supply and includes a built-in H4 RFI filter (Class A1/C2), ensuring compliance with electromagnetic compatibility standards in most industrial and commercial environments. The drive features an integrated HVAC-specific software suite, including a built-in PID controller for pressure and flow regulation, as well as a specialized "Fire Mode" for safety-critical smoke extraction fans. The 4.9 kg lightweight chassis is optimized for DIN rail or backplate mounting, and its modular design allows for rapid parameter setup using the local control panel or PC-based software.

Technical Specifications

Feature Specification
Model FC-101P7K5T4E20H4 (131L9868)
Brand Danfoss
Power Rating 7.5 kW / 10 HP
Input Voltage 3-Phase 380 - 480 VAC
Enclosure Rating IP20 / Chassis
RFI Filter H4 (Class A1/C2)
Phase Three Phase (T)
Efficiency > 98%
Operating Temp -10 to 40 deg C (Full load)
Net Weight 4.9 kg
Shipping Weight 8.0 kg

Technical FAQs

Does this drive support communication protocols common in HVAC?

Yes. The FC-101 series comes standard with built-in FC Protocol, Modbus RTU, and BACnet (MS/TP). This allows the 131L9868 to integrate seamlessly into Building Management Systems (BMS) for remote monitoring and centralized control of 7.5 kW motor loads.

What is the benefit of the H4 RFI filter in a commercial building?

The H4 (Class A1/C2) filter minimizes electromagnetic interference generated by the drive. This is critical in commercial settings to prevent the drive from disrupting sensitive electronics, communication lines, or office equipment sharing the same power grid.

Can the 131L9868 be used with permanent magnet (PM) motors?

The VLT® HVAC Basic Drive is primarily optimized for standard induction motors. While it provides excellent control for asynchronous motors, users requiring high-performance PM motor control should verify compatibility with the specific firmware version (SXXX) or consider the FC-102 series for advanced motor motor technology support.


Engineering & Installation Guide

  • Airflow Clearance: The FC-101 relies on vertical convection for cooling. Ensure a minimum of 100 mm clearance above and below the drive. Since this model is IP20, it must be installed in a clean, dry cabinet where the ambient temperature does not exceed 40 deg C to maintain the 7.5 kW power rating without derating.

  • Fire Mode Implementation: When utilizing the Fire Mode for life-safety applications, ensure the control logic is wired to a dedicated digital input. Note that when Fire Mode is active, the drive will ignore most internal protective trips to keep the fan running as long as possible; therefore, periodic testing of this loop is essential.

  • Cable Shielding: To maintain RFI Class A1 compliance, use shielded motor cables. The shield should be terminated with a 360-degree HF clamp at the drive's metal decoupling plate. Avoid "pigtail" grounding of the shield, as this creates high-frequency impedance and reduces the effectiveness of the H4 filter.

 

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Szürkésfehér
Country of origin
Dánia

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...