1 / 6

E82EV751_4C Lenze 8200-Series 0.75 kW Vector Frequency Inverter

E82EV751_4C Lenze 8200-Series 0.75 kW Vector Frequency Inverter

Only 7 item(s) left in stock
  • Manufacturer: Lenze

  • Product No.: E82EV751_4C

  • Country of origin:Németország

  • Product Type: Variable frequency drives

  • Barcode: 85044095

  • Payment: T/T, Western Union

  • Weight: 1100g

  • Dimensions: 17,80cm x 7,60cm x 22,90cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Product Overview

The E82EV751_4C (E82EV751K4C) is a high-performance Vector Frequency Inverter designed for modular precision within the Lenze 8200-Series lineup. Delivering a rated power of 0.75 kW, this drive is engineered for sophisticated speed and torque control in demanding industrial environments such as conveyor systems, pump stations, and ventilation control. By utilizing advanced vector control, the E82EV751_4C ensures high dynamic response and optimal motor efficiency, even at low speeds. As a phase-out component, it remains a critical asset for facility managers and maintenance engineers who require "like-for-like" replacements to maintain system integrity and avoid the high costs of complete control cabinet redesigns. Its robust German engineering guarantees long-term durability in continuous-duty cycles, providing a stabilized bridge for legacy system support.

Technical Configuration

The E82EV751_4C architecture is defined by its modularity and space-saving "bookcase" design. It features a triple-phase mains connection (3 x 400 / 500 VAC) and operates without integrated interference suppression, allowing for customized external filtering based on specific site requirements. The internal control logic supports high overload capacity (150% rated current for 60 seconds), which is essential for high-inertia startups. The unit is compatible with various plug-in modules, including fieldbus interfaces (CAN, PROFIBUS) and localized keypad units for manual parameterization. Its integrated motor protection functions, including thermal monitoring and short-circuit detection, ensure the drive and the connected motor are shielded from electrical irregularities.

Technical Specifications

Attribute Specification
Model E82EV751_4C / E82EV751K4C
Brand Lenze
Series 8200-Series Vector
Power Rating 0.75 kW (1.0 HP)
Input Voltage 3 x 400 / 500 VAC
Output Frequency 0 to 650 Hz
Overload Capacity 150% for 60 seconds
Protection Degree IP20
Dimensions 17.80 x 7.60 x 22.90 cm
Weight 1.10 kg
Country of Origin Germany
Commodity Code 85044095

Technical FAQs

Does the E82EV751_4C require an external RFI filter for operation?

Yes, as this specific model is supplied without internal interference suppression measures, an external RFI (Radio Frequency Interference) filter is recommended if the application must comply with strict CE electromagnetic compatibility (EMC) standards in residential or commercial grids.

What is the difference between the E82EV751_4C and the E82EV751K4C codes?

These refer to the same physical unit. The "K" in the second code often denotes "Kilowatt" notation in internal Lenze logistics, but they are functionally and electrically identical 0.75 kW units.

Can I use this drive for simple V/f control as well as Vector control?

Absolutely. The 8200-Series is versatile; while it excels in sensorless vector control for high torque applications, it can be easily configured for standard V/f characteristic curves for simpler fan and pump applications via the parameter settings.


Engineering & Installation Guide

  • Vibration and Mounting: The E82EV751_4C should be mounted vertically on a flat, vibration-resistant surface. In environments with high mechanical resonance (e.g., direct mounting on a vibrating machine frame), use vibration-dampening standoffs to protect the internal power electronics and control board solder joints from fatigue.

  • Cooling and Airflow: Maintain a minimum clearance of 50 mm above and below the unit to ensure unimpeded airflow. Since this unit is compact (7.60 cm wide), side-by-side mounting is possible, but you must monitor the internal cabinet temperature to ensure it does not exceed 40 Celsius to maintain the full 0.75 kW power rating without derating.

  • Wiring and Grounding: Given the lack of internal suppression, proper grounding is non-negotiable. Use a large-surface area ground connection (PE rail) and ensure the motor cable is as short as possible. For cable lengths exceeding 10 meters, consider output reactors to protect motor insulation from dV/dt voltage spikes.

 

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Szürkésfehér Fehér
Country of origin
Németország

Nemrég megtekintett termékek

Műszaki ismeretek

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...