1 / 3

GE DS2020DACAG2 EX2100 AC-DC Power Conversion Assembly

GE DS2020DACAG2 EX2100 AC-DC Power Conversion Assembly

Only 4 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: DS2020DACAG2

  • Country of origin:Egyesült Államok

  • Product Type: AC-DC Power Conversion Assembly

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 21950g

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

The DS2020DACAG2 operates as a ruggedized AC to DC power conversion assembly designed for integration within EX2100 excitation systems and Mark VIe control networks. This power supply module supplies regulated local energy to essential distribution architectures, effectively extending systemic control ride-through capabilities during line source failures or operation within completely battery-less configurations.

The structural circuit path of the DS2020DACAG2 executes rectification of alternative source feeds into structured direct current bus rails. Operating from a dual-tap 115 VAC or 230 VAC line entry, the module delivers an output potential rated at 126 VDC with a maximum delivery boundary of 9.5 ADC under individual assembly usage. This rectified DC line couples to concurrent system energy feeds through an on-board diode network to build a common distribution bus, directly feeding secondary controller blocks, core module sectors, and active gate pulse amplifier cards. The conversion topology utilizes heavy-duty electrolytic storage capacitors to maintain ripple filtering, accompanied by dedicated diagnostic LED indicators arranged at downstream modules (such as EPDM, EGPA, EXTV, and EPBP) to verify consistent power rail health. For expanded system loads, multiple units can be coupled in parallel configurations via a standardized 12-position connector interface to boost aggregate loop outputs to 16.5A DC.

Features

  • Dual-Voltage Input Conversion: Rectifies standard 115 VAC or 230 VAC utility inputs into a stabilized 126 VDC configuration loop.
  • Parallel Core Scaling: Supports dual-module parallel load sharing across a shared bus to increment total output delivery up to 16.5A DC.
  • Integrated Ride-Through Buffering: Provides localized capacitive hold-up capacity to secure system control execution parameters over temporary line voltage drops.
  • Diode-Coupled Bus Isolation: Employs built-in steering diodes to seamlessly tie converted DC current with alternative backup battery rails.

Applications

  • EX2100 Excitation Bus Power: Delivers continuous rectified bus power to gate pulse amplifier boards and excitation distribution racks.
  • Mark VIe Battery-Less Controller Feeds: Main power conversion assembly deployed in turbine generator infrastructure missing static battery storage banks.
  • Industrial DC Distribution Maintenance: Used as a drop-in, fully backward-compatible replacement for obsolete Group 1 (DS2020DACAG1) modules.

Technical Specifications

Parameter Specification
Manufacturer General Electric (GE)
Model DS2020DACAG2
Product Series EX2100 Excitation Series / Mark VIe System
Module Type AC-DC Power Conversion Assembly
Functional Acronym DACA
Power Conversion Parameters 115/230 VAC input to 126 VDC output
Output Power Rating 1000 W
Maximum Output Current (Single) 9.5 ADC
Maximum Output Current (Parallel) 16.5 ADC
Capacitor Configuration Wear-replaceable Electrolytic Capacitors
Operating Temperature -22 to +140 degF (-30 to +60 degC) via free convection
Operating Humidity Bounds 5 to 95%, non-condensing
Calculated Life Expectancy 100 years at ambient temp of 68 degF (20 degC)
PCB Coating Profile Normal style surface coating
Replaces Model DS2020DACAG1 (Group 1)
Product Weight 48.39 lbs (21.95 kg)

Connections/Interfaces

Connector Identifier Terminal Layout Function
JZ Connector 12-Position Modular Block Integrated input path for raw AC entry and output pathway for rectified DC loops

Installation Guidelines

  • Bus Line De-energization: Verify total isolation and zero potential on all source input wires and parallel battery loops before attempting hardware replacement.
  • ESD Shielding Protocol: Installation engineers must stay attached to an approved, fully grounded anti-static wrist strap to avert dielectric shock to the inner circuit components.
  • Parallel Voltage Matching Requirements: If operating dual conversion assemblies in a parallel network, both blocks must hook into the identical AC source link to secure identical source input potentials.
  • Harness Interconnection Setup: When wiring the conversion assembly alongside an IS2020JPDF module, lock the specialized wiring harness firmly between the JPDF and JPDB terminals.

Are there any design differences between the DS2020DACAG1 and the DS2020DACAG2?

There are virtually no functional differences between the two models. The DS2020DACAG2 serves as a direct drop-in and fully backward-compatible replacement for the older DS2020DACAG1 module.

Can two parallel units be connected to separate AC power sources?

No. When running two parallel assemblies to increase current output to 16.5A, they must be tied to the exact same AC input source to maintain balanced input voltages.

How does extreme ambient operating temperature alter the expected service life of the module?

While the baseline life expectancy is 100 years at 68 degF, operating continuously at an elevated ambient temperature of 149 degF degrades the internal electrolytic capacitors, requiring module replacement roughly every five years.

What nominal voltage measurements should be checked on a grounded, coupled DC bus setup?

When the conversion module is correctly diode-coupled and grounded, nominal voltage checks across the bus rails should register +62.5 VDC and -62.5 VDC relative to ground.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Pontok Ezüst
Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...