The IC695NIU001 functions as a high-performance Ethernet Network Interface Unit (NIU) within the PACSystems RX3i control platform series. This dual-width communication module is engineered to enable the remote deployment and automatic execution of standard PACSystems RX3i and Series 90-30 I/O modules across a distributed Ethernet network architecture. Once established via user configuration, data exchange operates completely automatically, allowing system control to be driven by any master device capable of handling Ethernet Global Data (EGD) transfers. The IC695NIU001 continuously delivers diagnostic status markers back to the primary controller during every single data exchange, allowing application logic to dynamically monitor link health and issue real-time commands to the remote chassis. It utilizes basic Ethernet modules (such as the IC695ETM001) mounted in an RX3i Universal Backplane to establish network pathways, supporting secure SRTP TCP/IP communications and seamless integration with high-availability redundancy controllers.

Features

  • Coordinates fully automatic, high-speed remote I/O data transfers over network lines via Ethernet Global Data (EGD) services.
  • Provides 20 Kbytes of selectable local logic memory space supporting standard programming languages (excluding C programming).
  • Embeds 10 Mbytes of non-volatile flash user memory for secure local application data and hardware configuration backup.
  • Features an integrated, battery-backed calendar clock to preserve precise system time logs during host chassis power outages.
  • Incorporates two dedicated onboard serial communication ports (one RS-232 COM1 port and one RS-485 COM2 port) for local peripheral or programmer connections.
  • Supports execution of unique COMMREQ commands issued via Ethernet by C application blocks running in a master PACSystems RX7i or RX3i controller.

Applications

  • Distributed Remote I/O Networks: Extending and centralizing remote PACSystems RX3i and Series 90-30 I/O drops across expansive plant locations.
  • High-Speed Process Synchronization: Utilizing Ethernet Global Data highways to manage fast data exchanges in multi-node continuous manufacturing operations.
  • Infrastructure Redundancy Frameworks: Deploying automated fieldbus interfaces alongside redundancy controllers in mission-critical water, power, or oil and gas utilities.

Technical Specifications

Parameter Value
Manufacturer GE Fanuc (GE Intelligent Platforms)
Model Number IC695NIU001
Series PACSystems RX3i
Product Type Ethernet Network Interface Unit
Local Logic Memory 20 Kbytes (C programming not supported)
Non-Volatile Flash Memory 10 Mbytes
Onboard Serial Ports 1 x RS-232 (COM1), 1 x RS-485 (COM2)
Serial Protocols Supported Modbus RTU Slave, SNP Slave, Serial I/O, Message Mode
Data Exchange Capacity Up to 1300 bytes Input / 1300 bytes Output per exchange
Recommended Battery Pack 3-cell Lithium Battery Pack (IC698ACC701)
Compatible Programming Software Machine Edition Logic Developer version 5.51 or later
Backplane Slot Occupation Dual-width module (occupies 2 standard slots)
Weight 0.55 KG
Dimensions (W x H x D) 35 mm x 140 mm x 135 mm

 

Connections/Interfaces

Port Designation Physical Interface and Function
COM1 (Port 1) 9-pin female D-sub connector, RS-232 signaling; supports WinLoader firmware updates and direct programmer linkages
COM2 (Port 2) 15-pin female D-sub connector, RS-485 signaling; accepts RS-485 to RS-232 adapter (IC690ACC901) connections

 

Installation Guidelines

  • Verify that all incoming electrical power to the RX3i Universal Backplane is completely turned off before inserting or removing the network hardware.
  • Position the unit firmly inside a primary Universal Backplane (IC695CHS0xx) slot 0. As a dual-width module, it occupies two physical slots (typically slots 2 and 3). Do not place it in the rightmost slot of the backplane, as this slot lacks a physical securing latch.
  • Upon turning on rack power and completing internal system initialization, ensure that the front-panel NIU OK LED shines steady green, while the NIU SCANNING I/O and EN LEDs remain unlit until active scanning is configured.
  • To maximize the operational shelf life of the external lithium cell, do not attach the backup battery connector until after the module has been plugged in and powered up for the first time.
  • When executing field maintenance or replacing an exhausted battery, always leave rack power turned on; inserting a new battery pack while the system is completely powered down can trigger a startup fault during the next power cycle.

Compliance and Certifications

  • CSA: Certified by the Canadian Standards Association for safe deployment as industrial process control equipment within ordinary, non-hazardous locations.
  • Factory Mutual (FM): Approved as nonincendive equipment intended for use in Class I, Division 2, Groups A, B, C, and D hazardous environments.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Fanuc PACSystems RX3i IC695NIU001 Ethernet Network Interface Unit

How does the network interface unit exchange data with the central controller?

The device exchanges data over an Ethernet network using Ethernet Global Data (EGD) services. It is typically configured with two individual exchanges: one to receive outputs from the master controller and another to send local inputs back.

What is the correct procedure if the device fails to boot after a battery change error?

If the module fails to power up because a new battery was connected while the rack was entirely powered down, disconnect the battery, perform a full power cycle on the chassis, and then reattach the battery while the system is powered on.

Which industrial fieldbus protocols are supported by the onboard serial ports?

The embedded serial channels natively support Modbus RTU Slave, SNP Slave, standard Serial I/O interface configurations, and raw Message Mode communications.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Fekete
Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...