1 / 3

General Electric Mark VIe IS420UCSBH1A UCSB Controller Module

General Electric Mark VIe IS420UCSBH1A UCSB Controller Module

Only 7 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IS420UCSBH1A

  • Country of origin:Egyesült Államok

  • Product Type: UCSB Controller Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1520g

  • Dimensions: 5.5cm x 12.3cm x 20.3cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

The IS420UCSBH1A is a single-module industrial control processor developed by General Electric for the Mark VIe Control Safety System Series. Operating with the functional abbreviation UCSB, this hardware acts as the first generation of UCSB-type standalone control units executing real-world application logic for infrastructure and power plant applications. The IS420UCSBH1A is dynamically engineered with native configuration maps that allow it to function interchangeably as a primary controller within Mark VIe, EX2100e excitation control, and LS2100e static starter systems. Built around an embedded 600 MHz Intel EP80579 microprocessor, the module processes complex turbine application logic and controls communication interfaces without requiring a system backup battery or an integrated mechanical cooling fan assembly. It runs an operating software platform nearly identical to the subsequent UCSC series to maintain firmware compliance and configuration consistency across multi-generation system lifecycles.

Features

  • Integrated 600 MHz EP80579 Intel industrial microprocessor for consistent, deterministic processing loop execution.
  • Solid-state hardware design completely eliminates internal cooling fans and volatile backup battery requirements.
  • Multi-platform multi-purpose identity certified for Mark VIe, EX2100e, and LS2100e control architectures.
  • Compatible operating system structure delivering nearly identical application logic execution as the UCSC system controllers.
  • Certified for secure installation in both standard non-hazardous operating environments and Class I, Division 2 locations.

Applications

  • Gas, steam, and hydro turbine control systems within the Speedtronic product family.
  • EX2100e generator excitation control loop management.
  • LS2100e Static Starter control system logic execution.
  • Hazardous area process automation requiring Class I, Zone 2 or Division 2 safety standards.

Technical Specifications

Parameter Specification Value
Manufacturer General Electric (GE)
Model/Part Number IS420UCSBH1A
Functional Abbreviation UCSB
System Series Compatibility Mark VIe Control Safety System, EX2100e, LS2100e
Microprocessor Type Intel EP80579 (600 MHz clock speed)
Minimum Control Voltage 18 VDC
Nominal Power Supply Ratings 24 VDC / 28 VDC
Maximum Control Voltage 30 VDC
Maximum Current Rating 1.5 ADC
Ambient Operating Temperature Range -22 to 149 degF (-30 to 65 Celsius)
Cooling Mechanism Natural Convection (Fanless Architecture)
Manual Reference Guide GEH-6725 / GEH-6721
Country of Origin United States

Compliance and Certifications

Location Type Certification / Listing Agency Codes
ATEX Zone 2, Group IIC UL DEMKO 12 ATEX 1114875X
Class I, Zone 2, Group IIC UL E207685
Class I, Division 2, Groups A, B, C, D UL E207685
Non-Hazardous Locations UL E207685

Installation Guidelines

CRITICAL WARNING:

De-energize all secondary power distribution networks before inserting or disconnecting this module. Live maintenance in ATEX Zone 2 environments can trigger volatile ignition or cause permanent circuit damage to the processor base board.

1

Ensure proper cabinet clearance for passive vertical convection cooling. Air passage lanes around the chassis must remain unblocked by adjacent hardware assemblies.

2

Confirm the primary control voltage supply lines are conditioned within the structural operational envelope of 18 VDC to 30 VDC.

3

Verify structural grounding pads comply strictly with hazardous deployment guidelines detailed inside GEH-6725 documentation before starting system initialization sequences.

What is the recommended input voltage window for the controller?

The module requires a minimum control potential of 18 VDC and can accept up to a maximum of 30 VDC, with standard nominal ratings placed at 24 VDC and 28 VDC.

Does this controller model require an external cooling fan or internal battery?

No. The hardware is completely fanless and utilizes a battery-less design, depending entirely on natural convection through vertical cabinet orientation for thermal dissipation.

Is the controller compatible with system lines other than the Mark VIe?

Yes. This universal single module is labeled and fully authorized for deployment across Mark VIe, EX2100e excitation control, and LS2100e static starter control loops.

What specific safety classification numbers apply to its hazardous area usage?

It holds UL DEMKO 12 ATEX 1114875X for ATEX Zone 2 (Group IIC) environments, alongside UL E207685 covering Class I, Zone 2, Group IIC, and Class I, Division 2 (Groups A, B, C, D).

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Fekete
Country of origin
Egyesült Államok
Power source
DC áram

Nemrég megtekintett termékek

Műszaki ismeretek

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...