1 / 3

HIMA HIQuad F 6214 4 Fold Analog Input Module, Safety Related

HIMA HIQuad F 6214 4 Fold Analog Input Module, Safety Related

Only 10 item(s) left in stock
  • Manufacturer: HIMA

  • Product No.: F6214

  • Country of origin:Németország

  • Product Type: Analog Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 400g

  • Dimensions: 2.5cm x 12.7cm x 20.3cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Product Overview

F 6214 (F6214) is a safety related 4 channel analog input module designed for HIMA HIQuad systems. It processes 4 to 20 mA transmitter signals, voltage inputs from 0 to 10 V, and current inputs up to 20 mA with galvanic isolation. The module supports safety critical signal acquisition in industrial automation environments such as oil and gas, power generation, and chemical processing.

The module integrates 12 bit resolution signal conversion and ensures stable measurement performance under demanding operating conditions. It provides transmitter power supply and built in input filtering to reduce electrical noise. Engineers use it to improve process safety integrity and reduce unplanned shutdowns in critical control loops.

The design supports requirement class AK 1 to 6, ensuring compliance with safety related applications. The isolation architecture protects downstream systems from field wiring faults. It is widely deployed in redundant safety instrumented systems where reliability and fast diagnostics are required.

Suffix Breakdown

F 6214 does not use a multi level suffix structure. Configuration is defined by channel type and safety application class.

  • F 6214: Safety related analog input module

  • 4 fold: Four independent input channels

  • Analog input support: Voltage and current signals

  • Safety isolation: Galvanic separation between field and system side

  • AK 1 to 6: Requirement class for safety integrity applications

Technical Configuration

The module architecture is built around isolated input channels with independent signal conditioning. Each channel processes analog signals through filtering and analog to digital conversion with 12 bit resolution.

It supports mixed signal acquisition including 4 to 20 mA loops and voltage measurement inputs. The system integrates diagnostic monitoring for input wiring faults, overload conditions, and signal deviation detection.

Isolation barriers ensure separation between field devices and control system electronics. This reduces risk during fault conditions and improves system availability in safety critical environments.

Technical Specifications

Item Specification
Model F 6214
Brand HIMA
Origin Germany
Weight 0.4 kg
Dimensions 4 TE
Operating Temp 0 to 60 deg C
Power Consumption 5 V DC 150 mA, 24 V DC 250 mA

Technical FAQs

What signal types does the F 6214 support?
It supports 4 to 20 mA, 0 to 20 mA, and voltage inputs from 0 to 10 V.

Does the module provide channel isolation?
Yes, it provides safety isolation between field inputs and system electronics.

Can unused channels remain open?
No, unused channels must be terminated according to planning rules.

What is the resolution of signal conversion?
The module provides 12 bit resolution for analog signal processing.


Engineering & Installation Guide

Install the module inside a certified control cabinet with proper grounding to the system earth bar. Use shielded twisted pair cables for all analog inputs to reduce electromagnetic interference.

Maintain adequate airflow inside the cabinet to prevent heat accumulation. Keep spacing between modules according to rack design to ensure stable thermal conditions.

Avoid routing analog signal cables near high voltage or high current conductors. This reduces noise coupling and improves measurement accuracy.

Apply proper shielding termination at one end only to avoid ground loops. Verify isolation integrity before commissioning.

In hazardous environments, ensure enclosure compliance with zone classification requirements and follow all installation safety documentation.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Fekete Zöld Szürkésfehér
Country of origin
Németország
Power source
DC áram

Nemrég megtekintett termékek

Műszaki ismeretek

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...