1 / 1

Omron E5CN-C2TU E5CN Series Digital Temperature Controller

Omron E5CN-C2TU E5CN Series Digital Temperature Controller

Only 4 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: E5CN-C2TU

  • Country of origin:Japán

  • Product Type: Digital Temperature Controllers

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 48 x 48 mm (depth depends on mounting socket)

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Designed to deliver precise process thermal control in high-density panel configurations, the Omron E5CN-C2TU is a 1/16 DIN (48 x 48 mm) digital temperature controller engineered for industrial automation environments. This model utilizes a current output as its primary control output, making it highly compatible with modulating control devices such as silicon-controlled rectifiers (SCRs) and analog control valves. Featuring a multi-input architecture, it supports both thermocouples and platinum resistance thermometers (RTD) without requiring hardware reconfiguration. With built-in preventive maintenance functions, including an ON/OFF transition counter for the control outputs, this controller helps track relay degradation and schedule proactive maintenance cycles before field failures occur.

Key Features

  • Universal Input Configuration: Accommodates standard thermocouples and platinum resistance thermometers (Pt100/JPt100) within a single hardware variant.
  • Enhanced Processing Accuracy: Delivers precise PV indication accuracy of +/-0.3% for thermocouple inputs and +/-0.2% for RTD inputs.
  • Dual Auxiliary Outputs: Includes 2 independent auxiliary relay outputs for configuring safety limits, system interlocks, or process alarms.
  • PV/SV Status Display Function: Configurable to automatically alternate between the Process Value (PV) / Setpoint Value (SV) and active controller states such as auto/manual modes, RUN/STOP status, and alarm triggers.
  • Convenient Plug-in Design: The U-type configuration allows rapid controller body replacement from the front of the panel without disrupting terminal socket wiring.

Applications

  • Plastic extrusion and injection molding thermal zone management.
  • Industrial ovens, heat-treating chambers, and packaging seal jaw heaters.
  • Food processing pasteurizers, sterilizers, and tempering systems.
  • Environmental testing chambers and climate simulation systems.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model E5CN-C2TU
Product Class Basic-type Digital Temperature Controller (1/16 DIN)
Supply Voltage 100 to 240 VAC, 50/60 Hz
Dimensions 48 x 48 mm (depth depends on mounting socket)
Primary Control Output Current Output (4 to 20 mA DC / 0 to 20 mA DC)
Auxiliary Outputs 2 SPST-NO relay outputs
Input Formats Thermocouple or Resistance Thermometer (RTD)
Indication Accuracy Thermocouple: +/-0.3% of PV | RTD: +/-0.2% of PV
Base/Terminal Type Plug-in Model (Requires 11-pin socket)
Housing Color Black
Shipping Weight (Calculated) 1.1 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The E5CN-C2TU plug-in design is specifically intended for systems requiring rapid serviceability. It interfaces directly with standard Omron 11-pin sockets (such as P2CF-11 or P3GA-11). When replacing older E5CN generation controllers, confirm if the original unit was a direct screw-terminal type (E5CN-C2T) or a plug-in type (E5CN-C2TU); a standard terminal-block model cannot plug into an 11-pin base without replacing the housing and socket wiring assembly.

Application Pitfalls & Engineering Notes

Because this controller utilizes an analog current output (4-20 mA DC), pay close attention to the allowable load impedance of the receiving control device (e.g., SCR driver or modulating valve positioner). Exceeding the controller's maximum load resistance limit will cause output saturation and non-linear control loops. Additionally, ensure the sensor cabling is completely segregated from power distribution paths to prevent induced high-frequency electrical noise from degrading PV reading accuracy.

Commissioning & Wiring Tips

When using thermocouple inputs, always ensure that the correct cold-junction compensation is active and that only matched thermocouple compensation wires are used for panel routing. For 3-wire RTD configurations, verify that all three lead wires have identical electrical resistance; any imbalance between the A, B, and B' lines will introduce systematic offset errors in the PV reading.

Installation Guidelines

CRITICAL WARNING: SAFETY FIRST

Before installing or removing the controller body from its socket, ensure the mains power supply (100 to 240 VAC) and all auxiliary contact circuit voltages are fully de-energized. Failure to disconnect active electrical power before extraction can result in electrical arcing, damage to the controller internal logic boards, or severe personal injury.

1
Ensure the cutout dimensions in the control panel face are exactly 45.0 mm x 45.0 mm (+0.6/-0 mm tolerance) for standard 1/16 DIN mounting.
2
Secure the matching 11-pin socket (e.g., P3GA-11 for rear-mounting or P2CF-11 for DIN-rail/front-mounting) within your panel enclosure, following the specified terminal block wiring layout for power supply inputs on pins 5 and 6.
3
Align the keyway guide on the rear plug of the E5CN-C2TU controller with the center indexing hole of the wired 11-pin socket. Push the controller firmly inward until it seats flush and the securing side clips click into locked positions.

What is the primary control output of the E5CN-C2TU?

The E5CN-C2TU features an analog current output (typically 4-20 mA DC or 0-20 mA DC), which is designed for modulating actuators, SCR power control boards, or control valves.

Does this controller model have screw terminals directly on its casing?

No. The 'U' suffix in E5CN-C2TU indicates that it is a plug-in model. It requires an external 11-pin base socket (such as P2CF-11 or P3GA-11) for physical wiring connection.

What sensor types can be connected to this temperature controller?

This controller supports universal inputs, meaning it is compatible with standard thermocouples (such as K, J, T, E, L, etc.) and platinum resistance thermometers (RTDs like Pt100 and JPt100) selectable via the system menus.

How do the dual auxiliary outputs function on this controller?

The two auxiliary outputs are independent SPST-NO relay contacts that can be configured for process alarms (high, low, band limits), diagnostic error warnings, or basic interlock sequencing.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Japán

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...