VI451-11 Yokogawa Vnet/IP Communication Module

VI451-11 Yokogawa Vnet/IP Communication Module

Only 7 item(s) left in stock
  • Manufacturer: Yokogawa

  • Product No.: VI451-11

  • Country of origin:Japán

  • Product Type: Vnet/IP COMMUNICATION MODULE

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 740g

  • Dimensions: 3.2cm x 14.2cm x 20cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Product Overview

The VI451-11 (VI451-11) is a high-performance Vnet/IP Communication Module specifically designed for the Yokogawa CENTUM VP integrated production control system. Serving as the critical bridge for real-time control communication, this module enables the connection of Field Control Stations (FCS) and Human Interface Stations (HIS) over a 1 Gbps redundant Ethernet-based network. The VI451-11 is engineered to ensure deterministic data transmission, which is vital for maintaining process stability in large-scale industrial plants such as oil refineries, LNG terminals, and chemical processing facilities. By utilizing the Vnet/IP protocol, it combines the openness of standard Ethernet with the high reliability and "no-loss" data requirements of a Distributed Control System (DCS).

Network Logic & Redundancy

The Yokogawa VI451-11 architecture is built for "High Availability." It features dual-port redundancy (Bus A and Bus B) to prevent communication loss in the event of a cable break or switch failure. The suffix "-11" denotes the specific hardware revision and interface configuration, optimized for the V-series and high-speed Vnet/IP environments. Unlike standard commercial network cards, the VI451-11 manages time synchronization across the entire DCS network, ensuring that alarms and process events are time-stamped with millisecond precision. This module offloads the communication protocol stack processing from the main processor, allowing the controller to focus entirely on executing control logic without network-induced latency.

Technical Specifications

Attribute Specification Details
Model VI451-11
Brand Yokogawa
Series CENTUM VP / Vnet/IP
Interface Vnet/IP (1000Base-T)
Transmission Speed 1 Gbps (Full Duplex)
Connection Port 2 x RJ45 (Redundant Bus A & B)
Max Transmission Distance 100 m (Per segment using UTP Cat 5e/6)
Current Consumption 0.5 A (Maximum)
Operating Temp 0 to 50 deg C (32 to 122 Celsius)
Weight 0.28 kg
Shipping Weight 1 kg

Technical FAQs

How does Vnet/IP differ from standard industrial Ethernet?

Vnet/IP is a proprietary protocol layer developed by Yokogawa that runs on top of the standard UDP/IP stack. While standard Ethernet can suffer from packet collisions, the VI451-11 ensures that control data packets are prioritized and delivered with guaranteed timing, which is essential for PID loop stability.

Can the VI451-11 be hot-swapped while the FCS is running?

Yes, in a redundant configuration, a faulty VI451-11 can be replaced while the partner module maintains network communication. However, it is critical to follow the Yokogawa "Online Replacement" procedure to avoid unintended bus disturbances during the physical swap.

What cabling is required for optimal performance?

For the 1 Gbps speed of the VI451-11, high-quality Category 5e or Category 6 (Cat6) shielded twisted pair (STP) cabling is mandatory. Ensure that the total distance between the module and the network switch does not exceed 100 meters to maintain signal integrity.


Field Engineering & Installation Guide

  • Redundancy Verification: After installation, verify the "Active" and "Ready" LEDs on the front panel. Use the CENTUM VP maintenance tools to confirm that both Bus A and Bus B paths are communicating. A "Link" light on only one port indicates a physical layer issue that compromises system safety.

  • Switch Configuration: When connecting the VI451-11 to Layer 2/3 switches, ensure that Spanning Tree Protocol (STP) is disabled on the specific ports or configured for "PortFast" to prevent the switch from blocking control traffic during network re-convergence.

  • Grounding & EMI: Ensure the RJ45 connectors are fully seated and that the shielding of the Cat6 cable is properly grounded at the cabinet entry point. This is crucial for protecting the VI451-11 RISC processors from the high-frequency noise generated by Variable Frequency Drives (VFDs) in the plant.

Engineering Advantages

The VI451-11 represents the pinnacle of DCS communication engineering. Its ability to maintain a 1 Gbps throughput while providing hardware-based time synchronization makes it indispensable for modern high-speed processes. The module's ruggedized PCB coating protects against the corrosive atmospheres often found in upstream oil and gas operations. Furthermore, the VI451-11 is designed for long-term lifecycle support, ensuring that plants commissioned today can maintain network compatibility and spare part availability for decades to come.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Szürkésfehér Fekete
Country of origin
Japán
Power source
DC áram

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...