Bently Nevada 3500/15-05-00-CN Universal AC Power Supply Module

Bently Nevada 3500/15-05-00-CN Universal AC Power Supply Module

Hanya 8 item tersisa di stok
  • Produsen: Bently Nevada

  • Nomor Produk: 3500/15-05-00-CN

  • Negara asal:Amerika Serikat

  • Jenis Produk: Power Supply Module

  • Pembayaran: T/T, Western Union

  • Berat: 1390g

  • Dimensi: 120.7 mm x 50.8 mm x 251.5 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Description

The 3500/15-05-00-CN is a half-height module designed to power the 3500 Series Machinery Protection System. It must be installed in designated slots on the left side of the 3500 rack to convert a wide range of input voltages into regulated voltages required by other system modules. The 3500/15-05-00-CN functions as a universal AC power supply and operates alongside a universal AC Power Input Module (PIM). The 3500 rack can hold either a single supply or two redundant power supplies. In a dual configuration, the module in the lower slot acts as the primary supply, while the module in the upper slot serves as the backup supply. Redundant operation allows for the removal or insertion of either supply module without disrupting system operation.

Features

  • Half-height format optimizes rack space efficiency.
  • Redundant power capability provides seamless automatic backup when dual modules are installed.
  • Hot-swappable design permits module insertion and removal without interrupting rack functions.
  • Front panel "Supply OK" LED provides direct visual confirmation of proper module operation.
  • Over-voltage protection causes the fuse to open on the PIM to isolate the system from damaging voltage levels.
  • Under-voltage protection ensures low-voltage conditions do not cause harm to the supply or the PIM.

Applications

  • Turbo-machinery protection and condition monitoring
  • Power generation gas and steam turbine vibration instrumentation
  • Oil and gas refinery rotating asset protection
  • Petrochemical plant machinery monitoring systems
  • Heavy industrial compressor and pump protection systems

Ordering Information

Option Code Description
A: Power Supply Type (Top Slot) 05 Universal AC Voltage (85 to 264 Vac rms) 
B: Power Supply Type (Bottom Slot) 00 No Supply (Used when no supply is required) 

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada (Baker Hughes) 
Country of Origin USA 
Nominal Input Voltage 110 to 220 Vac nominal 
Input Voltage Range (Non-hazardous) 85 to 264 Vac rms 
Input Voltage Range (Hazardous) 85 to 250 Vac rms 
Input Voltage Peak 120 to 373 Vac pk 
Input Frequency 47 to 63 Hz 
Full Rack Current Draw 2.8 A rms (maximum) 
Power Supply Dimensions (H x W x D) 120.7 mm x 50.8 mm x 251.5 mm (4.75 in x 2.0 in x 9.9 in) 
Power Supply Weight 1.39 kg (3.06 lb) 
Power Input Module Dimensions (H x W x D) 120.7 mm x 25.4 mm x 114.3 mm (4.75 in x 1.0 in x 4.5 in) 
Power Input Module Weight 0.34 kg (0.75 lb) 
Operating Temperature -30 degC to +65 degC (-22 degF to +150 degF) 
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF) 
Humidity 95%, non-condensing 
Minimum Loading No minimum rack load is required 

Connections/Interfaces

Component / Terminal Function
Supply OK LED Front panel indicator that illuminates when the power supply operates properly.
Universal AC PIM Terminals Rear connections for Line (LN) and Neutral (NEUT) high-voltage AC inputs.
GND Protective Earth Ground connection point on the PIM.
FUSE Slot Holds the replaceable primary over-voltage protection fuse.

Installation Guidelines

  • Rack Positioning: Install the module only in the dedicated half-height slots located on the far left side of the 3500 rack.
  • PIM Matching: Ensure the associated Universal AC Power Input Module (PIM) is mounted directly behind the power supply module in the rear of the chassis.
  • Redundancy Allocation: For redundant configurations, locate the primary supply in the lower slot and the secondary backup supply in the upper slot.
  • Electrical Safety: Connect the structural grounding system securely to the rear PIM ground terminal to reduce electrical noise and ensure safety.
  • Compatibility Check: Verify that the universal AC supply and its corresponding PIM are not mixed or cross-connected with legacy Bently Nevada high/low voltage AC components, as they are incompatible.

Compliance and Certifications

  • EMC Directives: 2014/30/EU 
  • EMC Standards: EN 61000-6-2 (Immunity for Industrial Environments), EN 61000-6-4 (Emissions for Industrial Environments) 
  • Electrical Safety: Low Voltage Directive 2014/35/EU, EN 61010-1 
  • RoHS: ROHS Directive 2011/65/EU 
  • Maritime Classifications: DNV GL rules for classification (Ships, offshore units, high speed and light craft), ABS Rules for Condition of Classification (Part 1, Steel Vessels, Offshore Units and Structures)
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 3500/15-05-00-CN Universal AC Power Supply Module

Can this power supply module be used in redundant configurations?

Yes, but this specific model (3500/15-05-00-CN) features a '00' option for the bottom slot, meaning it does not ship with a second supply. To achieve full physical utility redundancy, you must install an additional compatible input supply in the lower slot of the rack chassis.

What input voltages are supported by the 05 option?

The 05 option denotes a Universal AC input, which safely accepts alternating voltages from 85 to 264 Vac rms. It functions reliably on standard 110/120 Vac and 220/240 Vac global distribution systems.

Does this module require diagnostic software for commissioning?

No. The power supply works immediately upon receiving input power, supplying the necessary DC rails to the rack backplane automatically. Status LED indicators on the front panel provide real-time diagnostic health.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...