ABB

ABB 3ASD489301A410 YPK 107E Legacy DC Drives Communication Module

SKU 3ASD489301A410

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB
  • Product No.: 3ASD489301A410
  • Origin Switzerland
  • Product Type: Communication Module
  • Barcode: 85389091
  • Payment: T/T, Western Union
  • Weight: 0.39 kg
  • Dimensions: 30.4 cm x 15.4 cm x 3 cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The ABB 3ASD489301A410 YPK 107E is a multi-processor communication board configured with integrated operational software for legacy industrial DC drive systems. Operating as a core data routing interface within specialized drive intelligence networks, this component processes multi-processor commands and manages critical synchronization tasks across distributed drive components. The assembly provides structural backplane connectivity and protocol processing to maintain clean signal pathways, serving as an engineered replacement to resolve communication time-outs, node dropouts, and command processing faults in legacy drive infrastructure.

Features

  • Pre-Loaded Firmware: Shipped complete with factory MP-COMM system software pre-installed on the onboard logic chips.
  • Broad Legacy Support: Engineered explicitly for industrial DC drive control racks utilizing legacy multi-processor architectures.
  • Dual-Model Supercession: Serves as the factory-designated direct replacement for obsolete product IDs YT204001-EC and YT204001-HC.
  • Chassis Mounting: Rigid PCB frame architecture with integrated interface pin headers for standardized rack backplane insertion.

Applications

  • Overhaul and logic board replacement in legacy ABB industrial DC drive systems.
  • Multi-processor network stabilization in metals processing, rolling mills, and mining sector drive control panels.
  • Upgrading degraded communication interfaces showing intermittent data transmission errors or frame drops.

Technical Specifications

Parameter Value
Manufacturer ABB
ABB Type Designation YPK 107E
Product ID 3ASD489301A410
Replaced Product IDs (Old) YT204001-EC, YT204001-HC
Software Integration MP-COMM Software Included
Part Type Original New
UNSPSC Classification 39120000
Country of Origin Sweden (SE)
Customs Tariff Number 85389091
Product Net Weight 0.390 kg
Shipping Weight (Calculated) 0.650 kg
Package Dimensions (Calculated) 240 x 170 x 60 mm

Installation Guidelines

CRITICAL WARNING:

Disconnect and lock out all AC mains and auxiliary power feeds to the drive enclosure before removing processing hardware. High-voltage DC buses retain hazardous charges even after power-down. Verify that bus capacitor voltages have fully discharged to safe levels using a certified voltmeter before handling internal circuitry.

1
Attach an approved, tested electrostatic discharge wrist strap to a verified bare-metal chassis ground point prior to opening the anti-static packaging.
2
Tag and disconnect all internal ribbon interfaces, serial cables, and terminal connections from the active board face to prevent strain on external harnesses.
3
Loosen the retaining screws, unlatch the card guides, and slide the legacy board smoothly out from the subrack backplane connectors.
4
Align the new board along the mounting tracks, push firmly until seated into the rear backplane socket, tighten retention fasteners, and reconnect all communication lines.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
Is the software required for the module included with this item?
Yes, this product is shipped with the proprietary MP-COMM system software pre-loaded on the module internal storage.
Can this board replace older part numbers like YT204001-HC?
Yes, this component is the factory-designated direct replacement for both YT204001-EC and YT204001-HC legacy items.
Does this card handle high voltage drive connections directly?
No, this is a multi-processor logic and communication interface module that processes low-voltage data signals; it does not connect directly to primary power lines.
Reviews

3ASD489301A410

Stock & lead time on request

Call
1 su 3

ABB 3ASD489301A410 YPK 107E Legacy DC Drives Communication Module

Only 3 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: 3ASD489301A410

  • Country of origin:Switzerland

  • Product Type: Communication Module

  • Barcode: 85389091

  • Payment: T/T, Western Union

  • Weight: 390g

  • Dimensions: 30.4 cm x 15.4 cm x 3 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The ABB 3ASD489301A410 YPK 107E is a multi-processor communication board configured with integrated operational software for legacy industrial DC drive systems. Operating as a core data routing interface within specialized drive intelligence networks, this component processes multi-processor commands and manages critical synchronization tasks across distributed drive components. The assembly provides structural backplane connectivity and protocol processing to maintain clean signal pathways, serving as an engineered replacement to resolve communication time-outs, node dropouts, and command processing faults in legacy drive infrastructure.

Features

  • Pre-Loaded Firmware: Shipped complete with factory MP-COMM system software pre-installed on the onboard logic chips.
  • Broad Legacy Support: Engineered explicitly for industrial DC drive control racks utilizing legacy multi-processor architectures.
  • Dual-Model Supercession: Serves as the factory-designated direct replacement for obsolete product IDs YT204001-EC and YT204001-HC.
  • Chassis Mounting: Rigid PCB frame architecture with integrated interface pin headers for standardized rack backplane insertion.

Applications

  • Overhaul and logic board replacement in legacy ABB industrial DC drive systems.
  • Multi-processor network stabilization in metals processing, rolling mills, and mining sector drive control panels.
  • Upgrading degraded communication interfaces showing intermittent data transmission errors or frame drops.

Technical Specifications

Parameter Value
Manufacturer ABB
ABB Type Designation YPK 107E
Product ID 3ASD489301A410
Replaced Product IDs (Old) YT204001-EC, YT204001-HC
Software Integration MP-COMM Software Included
Part Type Original New
UNSPSC Classification 39120000
Country of Origin Sweden (SE)
Customs Tariff Number 85389091
Product Net Weight 0.390 kg
Shipping Weight (Calculated) 0.650 kg
Package Dimensions (Calculated) 240 x 170 x 60 mm

Installation Guidelines

CRITICAL WARNING:

Disconnect and lock out all AC mains and auxiliary power feeds to the drive enclosure before removing processing hardware. High-voltage DC buses retain hazardous charges even after power-down. Verify that bus capacitor voltages have fully discharged to safe levels using a certified voltmeter before handling internal circuitry.

1
Attach an approved, tested electrostatic discharge wrist strap to a verified bare-metal chassis ground point prior to opening the anti-static packaging.
2
Tag and disconnect all internal ribbon interfaces, serial cables, and terminal connections from the active board face to prevent strain on external harnesses.
3
Loosen the retaining screws, unlatch the card guides, and slide the legacy board smoothly out from the subrack backplane connectors.
4
Align the new board along the mounting tracks, push firmly until seated into the rear backplane socket, tighten retention fasteners, and reconnect all communication lines.

Is the software required for the module included with this item?

Yes, this product is shipped with the proprietary MP-COMM system software pre-loaded on the module internal storage.

Can this board replace older part numbers like YT204001-HC?

Yes, this component is the factory-designated direct replacement for both YT204001-EC and YT204001-HC legacy items.

Does this card handle high voltage drive connections directly?

No, this is a multi-processor logic and communication interface module that processes low-voltage data signals; it does not connect directly to primary power lines.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
Switzerland

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.