Equipment Overview

The ABB 3ASD573001A1 YPP 110A (YPP110A) is a dedicated heavy-duty industrial application controller board designed for high-power legacy motor drive infrastructure. Functioning as the localized computational intelligence module, this ABB YPP 110A assembly executes real-time control algorithms, drive application logic, and system-level coordination parameters. The unit is optimized to maintain high structural data integrity and processing stability within variable speed control cabinets, minimizing localized signal latency and preventing communication drops between power conversion segments and higher-level networks.

Operational Attributes

  • Application Logic Execution: Built to process complex internal drive code sequences, multi-loop feedback calculations, and system interlocking routines natively.
  • Synchronized Communication Subsystem: Integrates directly with the system bus layout to ensure deterministic command handling and data delivery across legacy drive setups.
  • Drop-In Form Factor Configuration: Formulated to mirror original physical specifications exactly, eliminating mounting adjustments during field swap-outs.
  • Lifecycle Preservation Pathway: Provides a factory-sanctioned route for system support continuity via the cross-referenced manufacturer service update path.

Target Deployments

  • YGMV / YGMW Legacy Systems: Deployed as the primary logical processing core managing heavy-duty direct current motor fields.
  • YHMV / YHMW Drive Enclosures: Handles continuous parameter validation and control loop tuning under unstable industrial load conditions.
  • TYRAK LCI Medium Voltage Drives: Manages high-power synchronous motor configurations requiring specialized execution profiles within medium-voltage AC networks.

Technical Specifications

Parameter Category Verified Engineering Value
Original Equipment Manufacturer ABB Drives
Type Designation YPP 110A 
Unique Product ID 3ASD573001A1
Functional Classification Application Controller (APPLICATION CTRLR)
Customs Tariff Code 85049099
Direct Replacement Code DCF1061134R0001
Primary Logistical Origin Sweden (Logistic Center Sweden)
Product Net Weight 0.80 kg
Shipping Weight (Calculated) 1.45 kg
Package Dimensions (Calculated) 31.0 cm x 23.5 cm x 6.5 cm

Field Installation Protocols

CRITICAL WARNING: HIGH VOLTAGE SYSTEM ISOLATION

Isolate all electrical links feeding the target drive bay prior to commencing hardware replacement. Confirm that both high-voltage supplies and auxiliary lower-voltage power pathways are fully locked and tagged out. Verify the absence of potential voltage charges across input stages to eliminate residual capacitor energy hazards.

  1. 1 Put on a verified and properly grounded electrostatic discharge wrist strap before extracting the controller card from its anti-static shielding.
  2. 2 Align the module backplane layout carefully with the internal chassis mounting tracks of the legacy drive cage assembly.
  3. 3 Slide the board steadily until the primary bus seating interfaces latch firmly. Fully secure all mechanical retention anchors to ground the module faceplate.
  4. 4 Connect all local ribbon headers, field communication drops, and peripheral wire links. Perform a complete mechanical check prior to re-energizing the cabinet.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
Which specific legacy drive systems are compatible with this application controller?
This module is designed for legacy ABB direct current drive setups including YGMV, YGMW, YHMV, and YHMW, alongside TYRAK LCI medium voltage alternating current drive series.
What is the recommended replacement product ID if this unit must be upgraded?
The manufacturer identifies product ID DCF1061134R0001 as the official direct replacement product configuration for this module.
Are specialized static prevention safety practices required when replacing this component?
Yes. Grounded electrostatic discharge wrist straps and standard clean handling procedures must be maintained throughout installation to protect sensitive onboard processing components.
Is it safe to hot-swap this application controller during system operation?
No. The drive system must be fully powered down and electrically isolated before removing or installing this board to protect internal hardware from bus short circuits.
Reviews

YPP110A 3ASD573001A1

Stock & lead time on request

Call
1 su 3

ABB 3ASD573001A1 YPP 110A AC Drives Application Controller

Only 2 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: YPP110A 3ASD573001A1

  • Country of origin:Sweden

  • Product Type: Application Controller

  • Barcode: 85049099

  • Payment: T/T, Western Union

  • Weight: 800g

  • Dimensions: 31.0 cm x 23.5 cm x 6.5 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Equipment Overview

The ABB 3ASD573001A1 YPP 110A (YPP110A) is a dedicated heavy-duty industrial application controller board designed for high-power legacy motor drive infrastructure. Functioning as the localized computational intelligence module, this ABB YPP 110A assembly executes real-time control algorithms, drive application logic, and system-level coordination parameters. The unit is optimized to maintain high structural data integrity and processing stability within variable speed control cabinets, minimizing localized signal latency and preventing communication drops between power conversion segments and higher-level networks.

Operational Attributes

  • Application Logic Execution: Built to process complex internal drive code sequences, multi-loop feedback calculations, and system interlocking routines natively.
  • Synchronized Communication Subsystem: Integrates directly with the system bus layout to ensure deterministic command handling and data delivery across legacy drive setups.
  • Drop-In Form Factor Configuration: Formulated to mirror original physical specifications exactly, eliminating mounting adjustments during field swap-outs.
  • Lifecycle Preservation Pathway: Provides a factory-sanctioned route for system support continuity via the cross-referenced manufacturer service update path.

Target Deployments

  • YGMV / YGMW Legacy Systems: Deployed as the primary logical processing core managing heavy-duty direct current motor fields.
  • YHMV / YHMW Drive Enclosures: Handles continuous parameter validation and control loop tuning under unstable industrial load conditions.
  • TYRAK LCI Medium Voltage Drives: Manages high-power synchronous motor configurations requiring specialized execution profiles within medium-voltage AC networks.

Technical Specifications

Parameter Category Verified Engineering Value
Original Equipment Manufacturer ABB Drives
Type Designation YPP 110A 
Unique Product ID 3ASD573001A1
Functional Classification Application Controller (APPLICATION CTRLR)
Customs Tariff Code 85049099
Direct Replacement Code DCF1061134R0001
Primary Logistical Origin Sweden (Logistic Center Sweden)
Product Net Weight 0.80 kg
Shipping Weight (Calculated) 1.45 kg
Package Dimensions (Calculated) 31.0 cm x 23.5 cm x 6.5 cm

Field Installation Protocols

CRITICAL WARNING: HIGH VOLTAGE SYSTEM ISOLATION

Isolate all electrical links feeding the target drive bay prior to commencing hardware replacement. Confirm that both high-voltage supplies and auxiliary lower-voltage power pathways are fully locked and tagged out. Verify the absence of potential voltage charges across input stages to eliminate residual capacitor energy hazards.

  1. 1 Put on a verified and properly grounded electrostatic discharge wrist strap before extracting the controller card from its anti-static shielding.
  2. 2 Align the module backplane layout carefully with the internal chassis mounting tracks of the legacy drive cage assembly.
  3. 3 Slide the board steadily until the primary bus seating interfaces latch firmly. Fully secure all mechanical retention anchors to ground the module faceplate.
  4. 4 Connect all local ribbon headers, field communication drops, and peripheral wire links. Perform a complete mechanical check prior to re-energizing the cabinet.

Which specific legacy drive systems are compatible with this application controller?

This module is designed for legacy ABB direct current drive setups including YGMV, YGMW, YHMV, and YHMW, alongside TYRAK LCI medium voltage alternating current drive series.

What is the recommended replacement product ID if this unit must be upgraded?

The manufacturer identifies product ID DCF1061134R0001 as the official direct replacement product configuration for this module.

Are specialized static prevention safety practices required when replacing this component?

Yes. Grounded electrostatic discharge wrist straps and standard clean handling procedures must be maintained throughout installation to protect sensitive onboard processing components.

Is it safe to hot-swap this application controller during system operation?

No. The drive system must be fully powered down and electrically isolated before removing or installing this board to protect internal hardware from bus short circuits.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
Sweden

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...