Danfoss

Danfoss 060G3203 MBS 3300 Flush Diaphragm Pressure Transmitter

SKU 060G3203

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss
  • Product No.: 060G3203
  • Origin United States
  • Product Type: Pressure Transmitter
  • Payment: T/T, Western Union
  • Weight: 2.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Product Overview

The Danfoss 060G3203 is a high-precision pressure transmitter from the MBS 3300 series, specifically designed for applications where hygienic or viscous media monitoring is required. Featuring a flush diaphragm design, this transmitter eliminates the dead zones typically found in standard pressure ports, making it ideal for food and beverage processing, pharmaceutical manufacturing, or any process involving media that could clog a traditional recessed sensor. Built with an ATEX-approved, rugged construction, it ensures reliable performance and safety in demanding industrial environments.

Technical Configuration

The 060G3203 is engineered to provide stable, repeatable measurements while resisting media buildup and clogging.

  • Flush Diaphragm: The sensing element is mounted flush with the process connection, ensuring that the media flows directly across the diaphragm without creating pockets where residue or bacteria could accumulate.
  • Signal Integrity: It provides an industry-standard 4 - 20 mA output signal. With factory-set clipping levels (3.6 mA low / 22.4 mA high), the transmitter allows control systems to immediately detect open-circuit or short-circuit faults.
  • Environmental Resilience: Housed in an IP65-rated enclosure with a DIN-plug (EN 175301-803-A) electrical connection, the unit is protected against dust and low-pressure water jets, ensuring longevity in washdown environments.

Technical Specifications

Feature Specification
Model 060G3203
Brand Danfoss
Pressure Range 0 - 4 bar (0 - 58 psi)
Output Signal 4 - 20 mA
Accuracy (Typ.) 0.3 % FS
Connection G 1/2 A (Flush Diaphragm)
Max Overload 8 bar
Enclosure IP65
Weight 0.246 kg (Net)

FAQs

Why is a "flush diaphragm" necessary for my application? A flush diaphragm is critical in applications involving viscous fluids (like syrups, pastes, or slurries) or hygienic processes. Because the diaphragm is exposed directly to the main flow, it prevents the sensing port from clogging, which would otherwise lead to "ghost" readings or sensor failure in standard transmitters.

Can this transmitter be used in hazardous areas? The unit carries ATEX approval, which pertains to its safety characteristics in potentially explosive atmospheres. However, you must verify that the specific hazardous zone classification matches the ATEX rating of the device before installation.

Does the transmitter require periodic calibration? No, the 060G3203 does not support field adjustment of zero or span. It is factory-calibrated to ensure long-term stability. If the device falls out of its accuracy specification over many years of use, it should be replaced or returned to the factory for recalibration.

Engineering Guidelines and Best Practices

  • Installation Torque: The 27 mm hexagonal nut is designed for tightening. Use a proper wrench and ensure the hygienic or standard sealing gasket is seated correctly to avoid leaks or pressure-induced measurement errors.
  • Media Temperature: While the ambient rating is up to 85°C, the compensated temperature range is 0 - 80°C. For processes exceeding these temperatures, consider using a cooling extension or a "pigtail" siphon to protect the transmitter's internal electronics from excessive heat conduction.
  • Cleaning Protocols: In hygienic applications, ensure that your CIP (Clean-in-Place) or SIP (Sterilize-in-Place) chemicals are compatible with the stainless steel diaphragm material (typically 316L) to prevent surface pitting.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

060G3203

Stock & lead time on request

Call
1 su 1

Danfoss 060G3203 MBS 3300 Flush Diaphragm Pressure Transmitter

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 060G3203

  • Country of origin:United States

  • Product Type: Pressure Transmitter

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Product Overview

The Danfoss 060G3203 is a high-precision pressure transmitter from the MBS 3300 series, specifically designed for applications where hygienic or viscous media monitoring is required. Featuring a flush diaphragm design, this transmitter eliminates the dead zones typically found in standard pressure ports, making it ideal for food and beverage processing, pharmaceutical manufacturing, or any process involving media that could clog a traditional recessed sensor. Built with an ATEX-approved, rugged construction, it ensures reliable performance and safety in demanding industrial environments.

Technical Configuration

The 060G3203 is engineered to provide stable, repeatable measurements while resisting media buildup and clogging.

  • Flush Diaphragm: The sensing element is mounted flush with the process connection, ensuring that the media flows directly across the diaphragm without creating pockets where residue or bacteria could accumulate.
  • Signal Integrity: It provides an industry-standard 4 - 20 mA output signal. With factory-set clipping levels (3.6 mA low / 22.4 mA high), the transmitter allows control systems to immediately detect open-circuit or short-circuit faults.
  • Environmental Resilience: Housed in an IP65-rated enclosure with a DIN-plug (EN 175301-803-A) electrical connection, the unit is protected against dust and low-pressure water jets, ensuring longevity in washdown environments.

Technical Specifications

Feature Specification
Model 060G3203
Brand Danfoss
Pressure Range 0 - 4 bar (0 - 58 psi)
Output Signal 4 - 20 mA
Accuracy (Typ.) 0.3 % FS
Connection G 1/2 A (Flush Diaphragm)
Max Overload 8 bar
Enclosure IP65
Weight 0.246 kg (Net)

FAQs

Why is a "flush diaphragm" necessary for my application? A flush diaphragm is critical in applications involving viscous fluids (like syrups, pastes, or slurries) or hygienic processes. Because the diaphragm is exposed directly to the main flow, it prevents the sensing port from clogging, which would otherwise lead to "ghost" readings or sensor failure in standard transmitters.

Can this transmitter be used in hazardous areas? The unit carries ATEX approval, which pertains to its safety characteristics in potentially explosive atmospheres. However, you must verify that the specific hazardous zone classification matches the ATEX rating of the device before installation.

Does the transmitter require periodic calibration? No, the 060G3203 does not support field adjustment of zero or span. It is factory-calibrated to ensure long-term stability. If the device falls out of its accuracy specification over many years of use, it should be replaced or returned to the factory for recalibration.

Engineering Guidelines and Best Practices

  • Installation Torque: The 27 mm hexagonal nut is designed for tightening. Use a proper wrench and ensure the hygienic or standard sealing gasket is seated correctly to avoid leaks or pressure-induced measurement errors.
  • Media Temperature: While the ambient rating is up to 85°C, the compensated temperature range is 0 - 80°C. For processes exceeding these temperatures, consider using a cooling extension or a "pigtail" siphon to protect the transmitter's internal electronics from excessive heat conduction.
  • Cleaning Protocols: In hygienic applications, ensure that your CIP (Clean-in-Place) or SIP (Sterilize-in-Place) chemicals are compatible with the stainless steel diaphragm material (typically 316L) to prevent surface pitting.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
United States

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...