Product Overview

The Danfoss 134F3013 (FC-360H2K2T4E20H2BXCDXXSXXXXALBX) is a high-performance frequency converter from the VLT AutomationDrive FC-360 series, engineered for demanding industrial motor control applications. Designed specifically for robust environments found in water treatment, food and beverage processing, and general manufacturing, this drive provides precise speed regulation to optimize mechanical performance and reduce energy consumption. By integrating advanced vector control algorithms, the unit ensures stable torque output under variable loads, effectively minimizing mechanical stress on driven equipment and significantly reducing unplanned downtime in continuous production lines.

Suffix Breakdown

The 134F3013 model follows a rigorous Danfoss identification schema, detailing its specific hardware and software configuration:

  • FC-360: Denotes the VLT AutomationDrive 360 series platform.
  • H2K2: Rated for 2.2 kW (3.0 HP) output at High Overload.
  • T4: Designed for 380-480 VAC three-phase mains supply.
  • E20: IP20 / Chassis enclosure suitable for cabinet mounting.
  • H2: Integrated RFI Class A2 filter to minimize electromagnetic interference.
  • B: Equipped with an internal Brake Chopper for rapid deceleration management.
  • C: Coated PCB for enhanced protection against harsh, humid, or corrosive environments.
  • D: Features Loadsharing capability for multi-drive energy efficiency.
  • AL: Configured with a dedicated ProfiNet communication control card for industrial Ethernet integration.

Technical Specifications

Feature Specification
Model 134F3013
Brand Danfoss
Power Rating 2.2 kW / 3.0 HP
Voltage Input 380-480 VAC, 3-Phase
Enclosure Rating IP20 / Chassis
Communication ProfiNet
Brake Chopper Included
Coating Conformal Coated PCB
Weight 2.86 kg
Shipping Weight 5 kg
Operating Temp -10 deg C to 50 deg C

Frequently Asked Questions

Is the ProfiNet control card field-replaceable?

Yes, the control card architecture in the FC-360 series allows for modular maintenance, though it requires precise ESD handling procedures and firmware synchronization to ensure compatibility with the main drive processor.

Can this unit be used in environments with high vibration?

The unit is designed for industrial cabinet installation. While the internal components are robust, it is recommended to mount the drive on vibration-dampening rails if the installation environment exceeds standard IEC vibration specifications.

Does the integrated Brake Chopper require an external resistor?

Yes, the internal brake chopper manages the switching logic, but a compatible external braking resistor must be sized and connected to the DC bus terminals to dissipate the regenerated energy.

How do I troubleshoot an A2 RFI filter warning?

Check the grounding integrity of the cabinet and ensure the motor cable shielding is terminated according to EMC standards (360-degree connection to the drive chassis).

Engineering Guidelines and Installation Best Practices

  • Thermal Management: Given the IP20 enclosure, ensure the cabinet provides adequate forced-air ventilation. Maintain a minimum clearance of 100 mm above and below the unit to allow for unimpeded heat dissipation. Operating above 45 deg C may require de-rating of the output current.
  • Shielding and Grounding: To comply with electromagnetic compatibility standards, always use shielded motor cables. The cable shield must be bonded to the drive chassis using metal cable glands or clamps, ensuring a low-impedance high-frequency connection. Never bundle power cables with sensitive signal lines (e.g., ProfiNet or analog feedback cables).
  • Loadsharing Configuration: When utilizing the Loadsharing (D) feature, ensure that all drives connected to the DC bus are operating on the same DC potential. Verify that the DC bus voltage levels are equalized before closing the contactor between units to prevent high-current inrush that could damage the internal diodes.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

134F3013

Stock & lead time on request

Call
1 su 1

Danfoss 134F3013 VLT AutomationDrive FC-360 Frequency Converter

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 134F3013

  • Country of origin:United States

  • Product Type: VLT AutomationDrive

  • Payment: T/T, Western Union

  • Weight: 2860g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Product Overview

The Danfoss 134F3013 (FC-360H2K2T4E20H2BXCDXXSXXXXALBX) is a high-performance frequency converter from the VLT AutomationDrive FC-360 series, engineered for demanding industrial motor control applications. Designed specifically for robust environments found in water treatment, food and beverage processing, and general manufacturing, this drive provides precise speed regulation to optimize mechanical performance and reduce energy consumption. By integrating advanced vector control algorithms, the unit ensures stable torque output under variable loads, effectively minimizing mechanical stress on driven equipment and significantly reducing unplanned downtime in continuous production lines.

Suffix Breakdown

The 134F3013 model follows a rigorous Danfoss identification schema, detailing its specific hardware and software configuration:

  • FC-360: Denotes the VLT AutomationDrive 360 series platform.
  • H2K2: Rated for 2.2 kW (3.0 HP) output at High Overload.
  • T4: Designed for 380-480 VAC three-phase mains supply.
  • E20: IP20 / Chassis enclosure suitable for cabinet mounting.
  • H2: Integrated RFI Class A2 filter to minimize electromagnetic interference.
  • B: Equipped with an internal Brake Chopper for rapid deceleration management.
  • C: Coated PCB for enhanced protection against harsh, humid, or corrosive environments.
  • D: Features Loadsharing capability for multi-drive energy efficiency.
  • AL: Configured with a dedicated ProfiNet communication control card for industrial Ethernet integration.

Technical Specifications

Feature Specification
Model 134F3013
Brand Danfoss
Power Rating 2.2 kW / 3.0 HP
Voltage Input 380-480 VAC, 3-Phase
Enclosure Rating IP20 / Chassis
Communication ProfiNet
Brake Chopper Included
Coating Conformal Coated PCB
Weight 2.86 kg
Shipping Weight 5 kg
Operating Temp -10 deg C to 50 deg C

Frequently Asked Questions

Is the ProfiNet control card field-replaceable?

Yes, the control card architecture in the FC-360 series allows for modular maintenance, though it requires precise ESD handling procedures and firmware synchronization to ensure compatibility with the main drive processor.

Can this unit be used in environments with high vibration?

The unit is designed for industrial cabinet installation. While the internal components are robust, it is recommended to mount the drive on vibration-dampening rails if the installation environment exceeds standard IEC vibration specifications.

Does the integrated Brake Chopper require an external resistor?

Yes, the internal brake chopper manages the switching logic, but a compatible external braking resistor must be sized and connected to the DC bus terminals to dissipate the regenerated energy.

How do I troubleshoot an A2 RFI filter warning?

Check the grounding integrity of the cabinet and ensure the motor cable shielding is terminated according to EMC standards (360-degree connection to the drive chassis).

Engineering Guidelines and Installation Best Practices

  • Thermal Management: Given the IP20 enclosure, ensure the cabinet provides adequate forced-air ventilation. Maintain a minimum clearance of 100 mm above and below the unit to allow for unimpeded heat dissipation. Operating above 45 deg C may require de-rating of the output current.
  • Shielding and Grounding: To comply with electromagnetic compatibility standards, always use shielded motor cables. The cable shield must be bonded to the drive chassis using metal cable glands or clamps, ensuring a low-impedance high-frequency connection. Never bundle power cables with sensitive signal lines (e.g., ProfiNet or analog feedback cables).
  • Loadsharing Configuration: When utilizing the Loadsharing (D) feature, ensure that all drives connected to the DC bus are operating on the same DC potential. Verify that the DC bus voltage levels are equalized before closing the contactor between units to prevent high-current inrush that could damage the internal diodes.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...