HIMA F3430 is a four-channel safety-related relay output module for H41q/H51q and HIQuad system racks. Each channel uses a normally open relay contact. The module provides galvanic separation between the internal control circuitry and the field-side contacts.

Technical Specifications

Manufacturer HIMA
Model F3430
Product type Safety-related relay output module
System family H41q/H51q and HIQuad
Output channels 4 relay outputs
Contact arrangement Normally open, dust-tight contacts
Switching voltage 5–250 V AC or 5–110 V DC
Switching current 10 mA to 4 A per contact, subject to voltage and load limits
Maximum AC switching capacity 500 VA at power factor above 0.5
Maximum non-inductive DC capacity 120 W at 30 V DC; 50 W at 70 V DC; 30 W at 110 V DC
Typical switching time Approximately 8 ms
Typical reset time Approximately 6 ms
Space requirement 4 TE
Module current Less than 100 mA at 5 V DC; less than 120 mA at 24 V DC

Safety and Load Limits

HIMA lists F3430 as a SIL 3 relay module. Current HIMA revision documentation also states that F3430 is not certified to EN ISO 13849-1. It must not be assigned to a safety function that requires energization on demand without a project-specific safety review.

The 4 A contact figure is not a universal field-circuit rating. Voltage, load type, switching frequency and external protection remain part of the calculation. HIMA documentation limits fusing to 2.5 A when the module is used in safety controls. Inductive loads require separate assessment of inrush and suppression.

Replacement Checks

  • Record the existing F3430 hardware revision and rack slot before removal.
  • Confirm the four field circuits are wired as normally open relay outputs.
  • Check each load against the AC or DC switching-capacity limit, not only the 4 A contact limit.
  • Verify the mating cable plug, LED indication and terminal numbering against the installed drawing.
  • Review the proof-test interval and application logic before returning the safety function to service.

F3422, F3330 and F3331 are different output modules. Channel count, output technology, voltage range and wiring must be checked before any substitution.

Physical and Freight Data

Recorded product dimensions 20 × 190 × 127 mm
Recorded net weight 0.28 kg
Estimated protective package 260 × 80 × 190 mm
Estimated package volume 0.00395 m³

The product dimensions and weight are retained from the existing PLC ProTech product record. The protective package is an editorial estimate for air-freight planning; warehouse measurement controls the final quotation.

FAQ

Is HIMA F3430 interchangeable with F3422?

No. F3430 has four safety-related relay outputs rated up to 250 V AC or 110 V DC, while F3422 has a different channel count and contact rating. Verify wiring, load, connector and safety logic before substitution.

Can each F3430 channel switch 4 A in a safety circuit?

Four amperes is the contact-current limit, not a universal circuit rating. Voltage, load type and switching capacity also apply. HIMA documentation limits external fusing to 2.5 A when the module is used in safety controls.

Can F3430 be used for every SIL 3 output function?

No. HIMA lists F3430 as SIL 3 but also states that it is not certified to EN ISO 13849-1 and must not be used where the safety function requires energization on demand. The safety requirement specification controls the decision.

What should be recorded before replacing F3430?

Record the hardware revision, rack slot, four field circuits, mating cable plug, contact loads, suppression components, application logic and proof-test record before removal.

Are the package dimensions final?

No. The 260 × 80 × 190 mm protective package is an editorial air-freight estimate. Warehouse measurement controls the final shipping quotation.

View all FAQs →

Quantità
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 su 3
Only 10 item(s) left in stock
Quantità
Visualizza dettagli completi
Loading product navigation…

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

IC693DSM324 Replacement Checks: FSSB, Firmware and Follower Control

A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.

HIMA F3430 Replacement Checks: Contact Ratings and Safety Limits

A field-focused HIMA F3430 replacement guide covering relay contact ratings, DC load derating, fusing, F3330/F3331 differences, safety restrictions and commissioning records.

IC697PWR710 Replacement Checks: Load Budget and Dual-Rack Limits

A field-focused IC697PWR710 replacement guide covering 5 V load calculations, dual-rack limits, extension cables, input checks, protection behavior and hardware revision risks.

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.