Designed for seamless network integration, the FR-A8NC plug-in option card enables high-speed CC-Link communication for Mitsubishi Electric FR-A800 and FR-F800 series variable frequency drives. This interface module allows standard industrial inverters to be directly connected to a CC-Link network, facilitating centralized control, real-time monitoring, and parameter configuration from a host controller such as a PLC.

By implementing the FR-A8NC module, system integrators can significantly reduce physical control wiring, replace traditional parallel I/O setups, and access comprehensive drive diagnostics. The card mounts directly into the internal option slot of compatible VFDs, maintaining a compact physical footprint without requiring external mounting space.

Features

  • Enables direct connection of FR-A800 and FR-F800 drives to CC-Link industrial networks.
  • Supports remote command execution, including start/stop, forward/reverse, and frequency setting commands.
  • Provides real-time feedback for monitoring output frequency, current, and operational status.
  • Simplifies configuration by allowing direct access to inverter parameters over the network.
  • Internal plug-in design ensures a secure, vibration-resistant connection directly to the drive control board.

Applications

  • Automated material handling and conveyor systems.
  • Centralized pump and fan control systems in water treatment and HVAC facilities.
  • Factory automation and synchronized multi-drive assembly lines.
  • Packaging, textile, and paper processing machinery.

Technical Specifications

Manufacturer Mitsubishi Electric
Model / Part Number FR-A8NC
Product Series FR-A800 and FR-F800 Series
Network Type CC-Link (Ver. 1.10 and Ver. 2.00)
Module Type Network / Communication Plug-in Option
Shipping Weight 1.0 kg

Installation Guidelines

  • Ensure all input power to the variable frequency drive is completely disconnected and verify that the charge lamp is off before installing the option card.
  • Insert the plug-in option card securely into the designated internal slot of the drive and tighten the mounting screws to ensure proper grounding.
  • Route all communication cabling away from high-voltage motor lines and power cables to prevent electromagnetic interference (EMI).
  • Always install a termination resistor of the correct resistance rating at both physical ends of the CC-Link network segment.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
Which drive series are compatible with the FR-A8NC option card?
The FR-A8NC is compatible with Mitsubishi Electric FR-A800 and FR-F800 series variable frequency drives.
Does the FR-A8NC support both CC-Link Ver. 1.10 and Ver. 2.00?
Yes, this interface card supports both CC-Link Ver. 1.10 and Ver. 2.00 network protocols.
How does the FR-A8NC connect to the VFD?
It is an internal plug-in option card that mounts directly into one of the designated option slots on the drive's control board.
Reviews

FR-A8NC

Stock & lead time on request

Call
1 su 1

Mitsubishi Electric FR-A8NC FR-A/F800 Series CC-Link Communication Module

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-A8NC

  • Country of origin:United States

  • Product Type: Communication Modules

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Designed for seamless network integration, the FR-A8NC plug-in option card enables high-speed CC-Link communication for Mitsubishi Electric FR-A800 and FR-F800 series variable frequency drives. This interface module allows standard industrial inverters to be directly connected to a CC-Link network, facilitating centralized control, real-time monitoring, and parameter configuration from a host controller such as a PLC.

By implementing the FR-A8NC module, system integrators can significantly reduce physical control wiring, replace traditional parallel I/O setups, and access comprehensive drive diagnostics. The card mounts directly into the internal option slot of compatible VFDs, maintaining a compact physical footprint without requiring external mounting space.

Features

  • Enables direct connection of FR-A800 and FR-F800 drives to CC-Link industrial networks.
  • Supports remote command execution, including start/stop, forward/reverse, and frequency setting commands.
  • Provides real-time feedback for monitoring output frequency, current, and operational status.
  • Simplifies configuration by allowing direct access to inverter parameters over the network.
  • Internal plug-in design ensures a secure, vibration-resistant connection directly to the drive control board.

Applications

  • Automated material handling and conveyor systems.
  • Centralized pump and fan control systems in water treatment and HVAC facilities.
  • Factory automation and synchronized multi-drive assembly lines.
  • Packaging, textile, and paper processing machinery.

Technical Specifications

Manufacturer Mitsubishi Electric
Model / Part Number FR-A8NC
Product Series FR-A800 and FR-F800 Series
Network Type CC-Link (Ver. 1.10 and Ver. 2.00)
Module Type Network / Communication Plug-in Option
Shipping Weight 1.0 kg

Installation Guidelines

  • Ensure all input power to the variable frequency drive is completely disconnected and verify that the charge lamp is off before installing the option card.
  • Insert the plug-in option card securely into the designated internal slot of the drive and tighten the mounting screws to ensure proper grounding.
  • Route all communication cabling away from high-voltage motor lines and power cables to prevent electromagnetic interference (EMI).
  • Always install a termination resistor of the correct resistance rating at both physical ends of the CC-Link network segment.

Which drive series are compatible with the FR-A8NC option card?

The FR-A8NC is compatible with Mitsubishi Electric FR-A800 and FR-F800 series variable frequency drives.

Does the FR-A8NC support both CC-Link Ver. 1.10 and Ver. 2.00?

Yes, this interface card supports both CC-Link Ver. 1.10 and Ver. 2.00 network protocols.

How does the FR-A8NC connect to the VFD?

It is an internal plug-in option card that mounts directly into one of the designated option slots on the drive's control board.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.