Description

The Schneider Twido TWDLCDA40DRF is a compact programmable logic controller base designed for reliable automation and discrete control in industrial environments. Featuring an integrated 24 V DC power supply, this unit provides 24 digital inputs at 24 V DC and 16 digital outputs to support flexible machine and process automation tasks. Engineered for seamless integration into legacy automation architectures, the TWDLCDA40DRF ensures operational continuity with fully testable hardware configurations. Its robust compact profile makes it an ideal choice for engineers and technicians requiring dependable control solutions for discrete manufacturing and system retrofits.

Features

  • Compact 24 V DC supply design optimized for industrial control panels
  • 24 digital inputs operating at 24 V DC
  • 16 discrete digital outputs for actuator and indicator control
  • Phase-out lifecycle status suitable for legacy system maintenance and replacement
  • Fully testable hardware architecture for reliable operational continuity

Applications

  • Discrete manufacturing machinery
  • Conveyor and material handling systems
  • Small-scale packaging equipment
  • Legacy automation system retrofits and maintenance

Technical Specifications

Specification Value
Manufacturer Schneider Electric
Range Twido PLM
Model / Part Number TWDLCDA40DRF
Product Phase Phase-Out
Supply Voltage 24 V DC
Input Type 24 I 24 V DC
Output Type 16 O
Dimensions 17.80 x 10.20 x 7.60 cm
Weight 0.90 kg
Commodity Code 85371099
Export Control Regulations (ECCN) N

Installation Guidelines

  • Ensure proper 24 V DC power supply polarity before applying power to the unit.
  • Maintain adequate spacing around the enclosure to support standard thermal dissipation.
  • Securely mount the compact base onto standard industrial profiles or panel backplates.
  • Route control wiring separately from high-voltage power lines to mitigate potential EMI/RFI interference.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the input and output configuration of this PLC base?
The unit features 24 digital inputs at 24 V DC and 16 digital outputs.
What power supply voltage does the TWDLCDA40DRF require?
This module operates on a 24 V DC supply voltage.
What are the physical dimensions of the controller base?
The dimensions are 17.80 x 10.20 x 7.60 cm with a weight of 0.90 kg.
Reviews

TWDLCDA40DRF

Stock & lead time on request

Call
1 su 1

Schneider Twido TWDLCDA40DRF Twido Compact PLC Base

Only 9 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: TWDLCDA40DRF

  • Country of origin:France

  • Product Type: PLC Bases

  • Payment: T/T, Western Union

  • Weight: 900g

  • Dimensions: 17,80cm x 10,20cm x 7,60cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Schneider Twido TWDLCDA40DRF is a compact programmable logic controller base designed for reliable automation and discrete control in industrial environments. Featuring an integrated 24 V DC power supply, this unit provides 24 digital inputs at 24 V DC and 16 digital outputs to support flexible machine and process automation tasks. Engineered for seamless integration into legacy automation architectures, the TWDLCDA40DRF ensures operational continuity with fully testable hardware configurations. Its robust compact profile makes it an ideal choice for engineers and technicians requiring dependable control solutions for discrete manufacturing and system retrofits.

Features

  • Compact 24 V DC supply design optimized for industrial control panels
  • 24 digital inputs operating at 24 V DC
  • 16 discrete digital outputs for actuator and indicator control
  • Phase-out lifecycle status suitable for legacy system maintenance and replacement
  • Fully testable hardware architecture for reliable operational continuity

Applications

  • Discrete manufacturing machinery
  • Conveyor and material handling systems
  • Small-scale packaging equipment
  • Legacy automation system retrofits and maintenance

Technical Specifications

Specification Value
Manufacturer Schneider Electric
Range Twido PLM
Model / Part Number TWDLCDA40DRF
Product Phase Phase-Out
Supply Voltage 24 V DC
Input Type 24 I 24 V DC
Output Type 16 O
Dimensions 17.80 x 10.20 x 7.60 cm
Weight 0.90 kg
Commodity Code 85371099
Export Control Regulations (ECCN) N

Installation Guidelines

  • Ensure proper 24 V DC power supply polarity before applying power to the unit.
  • Maintain adequate spacing around the enclosure to support standard thermal dissipation.
  • Securely mount the compact base onto standard industrial profiles or panel backplates.
  • Route control wiring separately from high-voltage power lines to mitigate potential EMI/RFI interference.

What is the input and output configuration of this PLC base?

The unit features 24 digital inputs at 24 V DC and 16 digital outputs.

What power supply voltage does the TWDLCDA40DRF require?

This module operates on a 24 V DC supply voltage.

What are the physical dimensions of the controller base?

The dimensions are 17.80 x 10.20 x 7.60 cm with a weight of 0.90 kg.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Beige
Country of origin
France
Power source
DC Power

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...