1 of 3

Allen-Bradley 1746-NIO4I SLC 500 Combination Analog I/O Module

Allen-Bradley 1746-NIO4I SLC 500 Combination Analog I/O Module

Only 6 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1746-NIO4I

  • Country of origin:Singapore

  • Product Type: Analog I/O Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 250g

  • Dimensions: 145 mm x 35 mm x 130 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Allen-Bradley 1746-NIO4I is a 4-channel combination analog input and output module designed for use with SLC 500 programmable logic controllers. The module integrates two differential analog input channels and two analog current output channels into a single-slot architecture to lower system cost and reduce chassis size. Each input channel can be individually configured for voltage (-10 to +10V dc) or current (-20 to +20 mA) signal operation via circuit board DIP switches. Inputs feature 16-bit resolution with low-pass digital filtering (10 Hz at 3 dB) for electrical noise immunity. Outputs provide 14-bit converter resolution across a 0 to 21 mA range. Backplane isolation protects control electronics from field-side electrical interference.

Features

  • Compact Combination Architecture: Integrates 2 analog inputs and 2 analog current outputs within a single-slot 1746 chassis layout.
  • High Signal Resolution: Features 16-bit input A/D conversion and 14-bit output D/A conversion.
  • Configurable Input Signals: DIP switches on the circuit board permit channel-by-channel selection between voltage (-10 to +10V dc) and current (-20 to +20 mA) inputs.
  • Noise Immunity: Low-pass filtering (10 Hz at 3 dB) delivers 105 dB common-mode rejection at 60 Hz.
  • Removable Terminal Block: Includes a 1746-RT28 terminal block to allow module replacement without disconnecting field wiring.
  • Automatic Data Updates: Executes end-of-scan I/O updates automatically without requiring specialized ladder program commands.
  • Electrical Isolation: Features backplane-to-field isolation rated for 500V dc continuous.

Applications

  • Process variable monitoring and loop control (e.g., flow, pressure, temperature transmitters).
  • Actuator and control valve positioning using 0 to 20 mA or 4 to 20 mA current loops.
  • Distributed industrial automation within SLC 500 PLC chassis installations.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Catalog Number 1746-NIO4I
Product Class Programmable Logic Controller I/O Module
Country of Origin Singapore
Backplane Current (5V dc) 55 mA
Backplane Current (24V dc) 145 mA
Number of Inputs 2 differential channels
Number of Outputs 2 analog current channels
Input Signal Voltage -10 to +10V dc -1 LSB
Input Signal Current -20 to +20 mA
Input Impedance 500K ohms (to ANL COM) / 250 ohms (current mode)
Input A/D Converter 16-bit
Input Resolution (Current) 1.22070 uA/LSB
Input Resolution (Voltage) 305.176 uV/LSB
Input Filter Bandwidth 10 Hz at 3 dB
Common Mode Rejection 105 dB at 60 Hz
Output Signal Current 0 to 21 mA -1 LSB (normal 0-20 mA / 4-20 mA)
Output D/A Converter 14-bit
Output Resolution 2.56348 uA/LSB
Output Load Range 0 to 500 ohms
Step Response (Input) 60 ms
Step Response (Output) 2.5 ms (5 to 95%)
Communication Format 16-bit two's complement binary
Isolation Rating 500V dc continuous (field wiring to backplane)
Recommended Wire Size #14 AWG maximum
Terminal Block Type Removable (1746-RT28)
Operating Temperature 0 degC to +60 degC (+32 degF to +140 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Relative Humidity 5 to 95% (non-condensing)

Connections/Interfaces

Terminal Pin Function Description
1 Input Channel 0 Positive (IN 0+)
2 Input Channel 0 Negative (IN 0-)
3 Analog Common (ANL COM)
4 Input Channel 1 Positive (IN 1+)
5 Input Channel 1 Negative (IN 1-)
6 Analog Common (ANL COM)
7 Output Channel 0 (OUT 0)
8 Analog Common (ANL COM)
9 Not Used
10 Output Channel 1 (OUT 1)
11 Analog Common (ANL COM)

Installation Guidelines

  • Power Safety: Disconnect backplane power to the SLC 500 chassis and field devices before installing or wiring the module.
  • Module Placement: Insert the module into any available I/O slot in a 1746 chassis, except slot 0 (reserved for the CPU).
  • Input DIP Switch Setup: Set internal DIP switches S1 and S2 to CLOSED for current inputs or OPEN for voltage inputs prior to installation.
  • Cable Selection & Shielding: Use Belden 8761 shielded twisted-pair cable. Connect the cable shield drain wire to earth ground at one end only.
  • Wiring Routing: Keep analog signal wiring isolated from high-voltage power cables and inductive loads to mitigate noise interference.
  • Terminal Screw Torque: Fasten terminal screws to a torque rating between 0.7 and 0.9 Nm (6 to 8 in-lbs) to avoid stripping.
  • Unused Channels: Jumper unused input channels to ANL COM to prevent signal floating. Do not jumper unused current output terminals.

Compliance and Certifications

  • UL 508 Listed
  • CSA 22.2 No. 142 Approved (Class I Division 2 Hazardous Location)
  • CE Compliant (for applicable directives)

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1746-NIO4I SLC 500 Combination Analog I/O Module

How many input and output channels are provided on the module?

The module provides two differential analog input channels and two analog current output channels.

How are the input signal types configured on the device?

Input signal types (voltage or current) are selected individually per channel using internal DIP switches located on the circuit board.

What cable is recommended for field wiring implementation?

Belden 8761 shielded twisted-pair wire or an equivalent standard cable is recommended to maintain noise immunity.

Does the device supply loop power for analog transmitters?

No, the module does not provide loop power for analog inputs. An external power supply matching transmitter specifications must be used.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Singapore
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...