1 of 3

Allen-Bradley 1756-OB16IS ControlLogix Scheduled Isolated Output Module

Allen-Bradley 1756-OB16IS ControlLogix Scheduled Isolated Output Module

Only 6 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1756-OB16IS

  • Country of origin:United States

  • Product Type: Digital Output Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 200g

  • Dimensions: 3.5cm x 14.2cm x 14.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

The 1756-OB16IS is a digital output execution component built for the ControlLogix system configuration. It functions within a nominal 12/24V DC voltage envelope, featuring 16 channels that are isolated individual points designed to secure downstream circuitry against cross-signal disturbance and transient spikes. This module integrates 8 scheduled output points designed to enable precise synchronization matching coordinated machine sequences with reference to the Coordinated System Time. It installs inside standard control slots, interfacing with industrial field loads via specified removable termination assemblies to provide deterministic actuation and steady processing states under multiple manufacturing control configurations.

Features

  • Incorporates 16 isolated output channels providing basic insulation between output points and backplane circuits.
  • Features 8 scheduled outputs allowing time-stamped task performance linked directly with coordinated control architecture.
  • Provides sinking or sourcing load matching with an execution range spanning 10V DC to 30V DC field operations.
  • Delivers continuous visual verification of independent output channel execution states and module hardware health.
  • Supports electronic, software-configurable keying options to enforce accurate hardware module matching upon slot replacement.

Applications

  • High-speed sorting and discrete tracking machinery requiring timed sequence control.
  • Solenoid valve switching loops and isolated pilot relay driving circuits.
  • Multi-zone industrial heating elements requiring synchronized control pulses.

Technical Specifications

Parameter Specification
Outputs 16 individually isolated, 8 scheduled
Pilot Duty 2 A (DC-13SQ)
Voltage Category 12/24V DC sink/source
Operating Voltage Range 10...30V DC
Output Delay Time (Off to On) 1 ms max
Output Delay Time (On to Off) 2 ms max
Current Draw @ 5.1V 350 mA
Current Draw @ 24V 2.5 mA
Total Backplane Power 1.8 W
Power Dissipation, Max 3.6 W @ 60 degC (140 degF)
Thermal Dissipation 12.28 BTU/hr
Off-State Leakage Current Per Point, Max 0.5 mA per point
On-State Voltage Drop, Max 1.2V DC @ 2 A
Current Per Point, Max 2 A @ 30 degC (86 degF), 1 A @ 60 degC (140 degF) (linear derating)
Current Per Module, Max 8 A @ 30 degC (86 degF), 4 A @ 60 degC (140 degF) (linear derating)
Surge Current Per Point 4 A for 10 ms per point, repeatable every 2 s
Load Current, Min 1 mA per point
Scheduled Outputs Synchronization Within 16.7 s max, reference to the Coordinated System Time
States in Fault Mode Per Point Hold last state, On or Off (Off is default)
States in Program Mode Per Point Hold last state, On or Off (Off is default)
Isolation Voltage 250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output
Module Keying Electronic, software configurable
Removable Terminal Block 1756-TBCH, 1756-TBS6H
RTB Keying User-defined mechanical
Slot Width 1
Wire Category 1
Wire Type Copper
Enclosure Type None (open-style)
Temperature, Operating 0...60 degC (32...140 degF)
Temperature, Nonoperating -40...85 degC (-40...185 degF)
Relative Humidity 5...95% noncondensing
Vibration 2 g @ 10...500 Hz
Shock, Operating 30 g
Shock, Nonoperating 50 g
Emissions IEC 61000-6-4

Installation Guidelines

  • Ensure conductor routing follows specified guidelines for Wire Category 1 paths to reduce crosstalk with high-voltage power components.
  • Use only approved ControlLogix Removable Terminal Blocks, specifically models 1756-TBCH or 1756-TBS6H, to wire external field outputs.
  • Set the software-based electronic keying attributes accurately within the project configuration to prevent mismatched module replacement errors.
  • Apply appropriate current derating factors when operating ambient conditions rise, limiting per-point current to 1 A when reaching 60 degC.
  • Mount the open-style chassis assembly inside an enclosure that offers appropriate protective barrier sealing against environmental particulates.

Compliance and Certifications

  • cULus Listed Industrial Control Equipment (UL File E65584)
  • cULus Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations (UL File E194810)
  • CE (European Union 2014/30/EU EMC Directive, EN 61326-1, EN 61000-6-2, EN 61000-6-4, EN 61131-2; 2014/35/EU LVD Directive, EN 61131-2)
  • RCM (Australian Radiocommunications Act, EN 61000-6-4)
  • ATEX (European Union 2014/34/EU ATEX Directive, EN IEC 60079-0, EN IEC 60079-7, II 3 G Ex ec IIC T4 Gc, UL22ATEX2820X)
  • IECEx (IEC 60079-0, IEC 60079-7, II 3 G Ex ec IIC T4 Gc, IECEx UL 22.0065X)
  • UKex (UKEX Regulation 2016 No. 1107, Equipment protection by increased safety "e", UL22UKEX2602X, Zone 2 classification)
  • KC (Korean Registration of Broadcasting and Communications Equipment, Article 58-2 of Radio Waves Act)
  • UKCA (2016 No. 1091, 2016 No. 1101, 2016 No. 1107, 2012 No. 3032)
  • Morocco (Arrête ministériel n° 6404-15)
  • CCC (2020122309111998, CNCA-C23-01 CCC Implementation Rule Explosion-Proof Electrical Products)

What is the continuous isolation threshold provided by the device?

The device provides a continuous isolation voltage rating of 250V using basic insulation across outputs-to-backplane and output-to-output connection paths.

How do environmental conditions affect the maximum current allowance per point?

The maximum current per point is rated at 2 A when operating under an ambient temperature up to 30 degC, which then derates linearly down to 1 A as the temperature reaches 60 degC.

What happens to the outputs when the controller switches into Fault or Program mode?

Each output channel can be configured to hold its last state, turn On, or turn Off. The default parameter configuration enforces an Off state for both modes.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...