Designed for high-precision temperature sensing in demanding industrial environments, the Beckhoff EL3201-0010 is a 1-channel analog input terminal engineered to interface directly with resistance temperature detectors (RTDs). This EtherCAT terminal utilizes a 4-wire connection methodology, enabling active lead resistance compensation to achieve high measurement accuracy across varying environments.

By digitizing signals with 16-bit resolution, the EL3201-0010 RTD sensor terminal provides highly stable and linearized temperature monitoring. The module comes equipped with integrated digital filtering, limit value monitoring, and configurable conversion rates, making it an essential hardware component for critical thermal management, process monitoring, and calibration systems.

Features

  • Single-channel high-precision analog input optimized for Pt100 and other resistance sensors.
  • 4-wire connection technology for complete compensation of lead-wire resistance.
  • 16-bit resolution with an integrated configurable digital filter.
  • Compact 12 mm terminal housing with diagnostic and signal status LEDs.
  • Efficient power delivery and fast communication via the EtherCAT E-bus.
  • Built-in limit value monitoring and adjustable conversion times.

Applications

  • High-accuracy temperature loop control in chemical processing plants.
  • Thermal monitoring and safety interlocking in power generation facilities.
  • Precision climate control and environmental chambers.
  • Laboratory instrumentation and automated test stands.

Technical Specifications

Manufacturer Beckhoff
Part Number/Model EL3201-0010
Product Type EtherCAT Terminal (1-Channel Analog Input)
Number of Inputs 1
Connection Technology 4-wire
Supported Sensor Types Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, resistance measurement (10 Ohm to 1/4 kOhm), KTY sensors
Measuring Range -200 to +850 degC (Pt sensors); -60 to +250 degC (Ni sensors); -200 to +320 degC (high-precision)
Resolution 0.01 degC per digit
Conversion Time Approx. 24 ms default (4 to 500 ms configurable)
Input Filter Limit Frequency Typ. 1 kHz
Measuring Current < 0.5 mA (load-dependent)
Measuring Error < ±0.1 degC at 40 degC ambient temperature (4-wire, Pt100, -200 to +320 degC, 50 Hz filter)
Electrical Isolation 500 V (E-bus / signal voltage)
Current Consumption E-bus Typ. 190 mA
Process Image Bit Width 1 x 32 bit RTD input
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
Protection Rating IP20
Housing Material Polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight Approx. 60 g

Connections and Interfaces

Connection Parameter Specification
Solid Conductor Cross-section 0.08 to 2.5 mm² (AWG 28 to 14)
Stranded Conductor Cross-section 0.08 to 2.5 mm² (AWG 28 to 14)
Ferrule Cross-section 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm
Wiring Mechanism Spring actuation by screwdriver
Power Contacts Current Load Imax: 10 A

Installation Guidelines

  • Mount directly onto a standard 35 mm DIN rail (conforming to EN 60715) with an integrated lock.
  • Ensure stable side-by-side terminal mounting using the double slot and key connection mechanism.
  • Verify that the cumulative current consumption of the E-bus does not exceed the power supply limits of the upstream coupler or power terminal.
  • Utilize properly shielded cables for analog signal connections to prevent electromagnetic interference.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc

Which sensor types are supported by the Beckhoff EL3201-0010?

The EL3201-0010 supports Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, resistance measurements (10 Ohm to 1.2 or 4 kOhm), and KTY sensors.

What is the benefit of the 4-wire connection on the EL3201-0010?

The 4-wire connection technology enables the module to actively compensate for lead wire resistance, ensuring high accuracy over long distances without sensor drift.

What is the power consumption of this module from the E-bus?

The EL3201-0010 is powered directly via the E-bus and has a typical current consumption of 190 mA.

Does this terminal feature hazardous area approvals?

Yes, the module is certified under ATEX with the Ex marking: II 3 G Ex nA IIC T4 Gc.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...