1 of 3

General Electric IS220PAICH1A Mark VIe Analog I/O Pack

General Electric IS220PAICH1A Mark VIe Analog I/O Pack

Only 8 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IS220PAICH1A

  • Country of origin:United States

  • Product Type: Analog I/O Pack

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 2410g

  • Dimensions: 130 mm x 130 mm x 85 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The IS220PAICH1A is an analog I/O pack manufactured by General Electric Company USA (GE Industrial Systems) as part of the Mark VIe Series for turbine control and automated drive management systems. This pack interfaces directly with compatible terminal boards to handle dual-way analog input and output signal transitions. It supports specialized control configurations for gas, steam, and alternative energy wind turbine assemblies. Designed for installation inside 13-slot or 21-slot VME racks, the IS220PAICH1A typically operates within a Triple Modular Redundant (TMR) control architecture consisting of individual control modules, dedicated internal I/O nets, and central processor cards. The module integrates a conformal protective circuit coating to withstand aggressive industrial environments and features four front-facing status indicators paired with a base-mounted I/O port.

Features

  • Processes diverse industrial analog input and output channels for turbine control systems
  • Designed for deployment in Triple Modular Redundant (TMR) network architectures
  • Features an A-rated functional revision incorporating a conformal PCB defensive coating
  • Equipped with four faceplate status indicators for instant diagnostics
  • Built with an interface port located at the bottom of the casing assembly
  • Approved for operational safety across both non-hazardous and specialized hazardous locations

Applications

  • Gas turbine automated drive assembly management
  • Steam turbine loop control systems
  • Alternative energy wind turbine control applications
  • Distributed control architectures requiring reliable TMR verification

Technical Specifications

Parameter Specification
Manufacturer General Electric Company USA (GE Industrial Systems)
Part Number IS220PAICH1A
Series Mark VIe
Functional Acronym PAIC
Product Type Analog I/O Pack
Assembly Type IS220 Standard Module with Conformal PCB Coating
Ambient Temperature Range -22 to 149 Fahrenheit
Minimum Power Supply Voltage 27.4 VDC
Nominal Power Supply Voltage 28.0 VDC
Maximum Power Supply Voltage 28.6 VDC
Max Power Supply Current 0.49 A dc
Max Input Voltage (Channels 1-8) 10 V dc (with 20 mA dc Max Current)
Max Input Voltage (Channels 9-10) 5 V dc (with 20 mA dc Max Current)
Max Output Voltage 16.3 V dc (with 20 mA dc Max Current)
Max Analog Transmitter Voltage 25.2 V dc (with 21 mA dc Max Current)

Connections/Interfaces

Interface Component Compatible Model / Function
IS200STAIH1A Input-Output Terminal Board Interface
IS200STAIH2A Input-Output Terminal Board Interface
IS20TBAIH1C Input-Output Terminal Board Interface
Bottom I/O Port Dedicated port for local input/output link routing

Installation Guidelines

  • Rack Deployment: Install the I/O pack within its designated location inside a compatible 13-slot or 21-slot VME rack assembly.
  • Terminal Board Mating: Ensure correct structural connection with approved input-output terminal boards, including the TBAI (such as IS20TBAIH1C) or STAI (such as IS200STAIH1A and IS200STAIH2A) options.
  • Power Supply Integrity: Provide a direct current supply source within the critical boundaries of 27.4 VDC minimum and 28.6 VDC maximum, targeting a nominal voltage of 28.0 VDC.
  • TMR Setup Requirements: Align network cables and node addresses to sync properly with the independent control modules and individual I/O nets forming the Triple Modular Redundant loop.

Compliance and Certifications

  • Class I, Div. 2, Groups A, B, C, D Standard: ANSI/ISA - 12.12.01-2015
  • Class I, Zone 2, Group IIC
  • ATEX Zone 2, Group IIC
  • Non-Hazardous Location Certification: UL E207865
  • Hazardous Location Certifications: UL E207685, UL DEMKO 12 ATEX 1114875X

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

General Electric IS220PAICH1A Mark VIe Analog I/O Pack

Which terminal boards can interface with the module?

The device is compatible with the IS200STAIH1A, IS200STAIH2A, and IS20TBAIH1C input-output terminal boards.

What are the primary power supply requirements for the pack?

The pack operates with a nominal input of 28.0 VDC, maintaining strict operating thresholds between a minimum of 27.4 VDC and a maximum of 28.6 VDC at 0.49 A dc.

Where is this I/O pack typically installed within a system?

The typical installation location for the device is inside either a 13-slot or a 21-slot VME rack architecture.

What system architecture is this hardware optimized to support?

The module is designed to operate within a Triple Modular Redundant (TMR) architecture system utilizing individual control modules and dedicated network loops.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...