Omron NX-TS2101 NX Series Temperature Input Unit

Omron NX-TS2101 NX Series Temperature Input Unit

Only 5 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: NX-TS2101

  • Country of origin:Japan

  • Product Type: Temperature Input Modules

  • Payment: T/T, Western Union

  • Weight: 70g

  • Dimensions: 12 (W) x 100 (H) x 71 (D) mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for high-accuracy temperature monitoring within the Omron Sysmac platform, the NX-TS2101 serves as a 2-channel thermocouple temperature input module. This unit integrates into the NX Series I/O system, enabling precise thermal measurements for applications requiring tight temperature regulation. It supports the direct connection of multiple industrial thermocouple types, converting sensor inputs into digital values for real-time control.

The module features channel-to-channel isolation to prevent electrical interference and ground loops across process zones. Equipped with a high-density 16-point screwless push-in clamping terminal block, it simplifies field wiring and reduces installation times. Communication and synchronization are handled via the backplane, supporting free-run refreshing to maintain consistent signal updates.

Features

  • Two independent thermocouple input channels.
  • Broad thermocouple sensor support including K, J, T, E, L, U, N, R, S, B, WRe5-26, and PLII types.
  • High resolution of 0.1 degC maximum for standard sensors (0.2 degC maximum for R, S, and W types).
  • Fast conversion speed of 250 ms per unit.
  • Integrated transformer and photocoupler isolation between input circuits and the NX bus, as well as between individual input channels.
  • Screwless push-in clamping terminal block containing 16 connection terminals.
  • TS status indicator for clear operational diagnostics.

Applications

  • Plastic extrusion and injection molding thermal control systems.
  • Industrial ovens, kilns, and heat treatment furnaces.
  • Packaging machinery requiring precise heat sealing profiles.
  • Chemical processing and reactor thermal monitoring.
  • Food processing pasteurizers and storage systems.

Technical Specifications

ManufacturerPart Number / ModelProduct TypeNumber of InputsSupported Sensor TypesConversion TimeResolutionI/O Refreshing MethodAbsolute Maximum RatingInput ImpedanceInput Disconnection Detection CurrentWarm-up PeriodIsolation MethodInsulation ResistanceDielectric StrengthI/O Power Supply MethodNX Unit Power ConsumptionCurrent Consumption from I/O Power SupplyDimensionsWeight
Omron
NX-TS2101
Temperature Input Unit (Thermocouple)
2 points
K, J, T, E, L, U, N, R, S, B, WRe5-26, PLII
250 ms / Unit
0.1 degC max. (0.2 degC max. for R, S, or W types)
Free-Run refreshing
+/-130 mV
20 kOhm min.
Approx. 0.1 uA
30 minutes
Power: Transformer, Signal: Photocoupler (between inputs, and between inputs and NX bus)
20 MOhm min. between isolated circuits (at 100 VDC)
510 VAC between isolated circuits for 1 minute (leakage current 5 mA max.)
No supply
1.25 W max. (connected to CPU or Comm Control Unit); 0.90 W max. (connected to Comm Coupler Unit)
No consumption
12 (W) x 100 (H) x 71 (D) mm
0.07 kg

Connections and Interfaces

Terminal Configuration Function Description
Thermocouple Channel 1 (TC1) Positive and negative thermocouple wire connection points
Thermocouple Channel 2 (TC2) Positive and negative thermocouple wire connection points
Cold Junction Compensation (CJC) Internal circuit references for cold-junction compensation
NC Terminals No Connection (unused terminal allocations)

Installation Guidelines

  • Mount the unit on a standard 35 mm DIN rail alongside compatible NX Series CPU or communication coupler units.
  • Ensure correct thermocouple polarization when inserting leads into the screwless clamping terminals.
  • To achieve the stated conversion accuracy, allow the module to warm up for at least 30 minutes after power-up.
  • Route thermocouple extension cables away from high-voltage motor cables and power lines to reduce electromagnetic noise interference.

Which thermocouple types does the NX-TS2101 support?

The NX-TS2101 supports K, J, T, E, L, U, N, R, S, B, WRe5-26, and PLII thermocouple types.

What is the measurement resolution of this module?

The module provides a resolution of 0.1 degC max. For R, S, and W sensor types, the resolution is 0.2 degC max.

Does this module require an external I/O power supply?

No, the NX-TS2101 does not consume or require external I/O power. It is powered via the NX bus interface.

Why is there a warm-up period specified for the NX-TS2101?

A 30-minute warm-up period is required to stabilize the internal electronics and the cold junction compensation circuit to guarantee accurate temperature measurements.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...