Schneider Altivar 12 ATV12P075M3 Variable Frequency Drive

Schneider Altivar 12 ATV12P075M3 Variable Frequency Drive

Only 7 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: ATV12P075M3

  • Country of origin:France

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 1050g

  • Dimensions: 18,7cm x 18,7cm x 11,5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The ATV12P075M3 is a compact variable speed drive from the Altivar 12 series, specifically designed for controlling 3-phase asynchronous motors in simple industrial machines. This model is built for mounting on a base plate and is optimized for 200–240 V, 3-phase supply systems. With a power rating of 0.75 kW (1 hp), it offers precise speed control, energy efficiency, and easy integration through its built-in Modbus communication port, making it an ideal choice for applications like conveyors, pumps, and fans.

Features

  • 0.75 kW (1 hp) motor power rating
  • 200–240 V, 3-phase supply voltage
  • 4.2 A continuous output current
  • Built-in Modbus communication (RS 485)
  • Compact, base-plate mounted design
  • Advanced PID and "catch on the fly" functionality
  • Sensorless flux vector control for improved torque management

Applications

  • Material handling (conveyor systems)
  • Industrial pumps and fans
  • Small-scale packaging machinery
  • Automated assembly line components
  • HVAC and extractor systems

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range Altivar 12
Product Type Variable speed drive
Power Rating 0.75 kW (1 hp)
Supply Voltage 200–240 V (3-phase)
Output Current 4.2 A
Communication Modbus (RS 485, RJ45)
Enclosure IP20
Dimensions (mm) 143 x 72 x 102.2
Weight 0.7 kg
Commodity Code 85044095

Installation Guidelines

  • Mounting: Install vertically (±10°) to ensure optimal cooling. The base plate design allows for cabinet mounting, either individually or side-by-side.
  • Environment: Designed for indoor use in a clean environment (Pollution Degree 2). Keep ambient temperature between -10 degC and 40 degC for standard operation.
  • Wiring: Use shielded motor cables to minimize electromagnetic interference. Ensure the drive and motor frames are securely connected to a common system ground.
  • Cooling: Since this model lacks an internal fan, ensure the installation area provides adequate natural ventilation and heat dissipation.
  • Safety: Always disconnect power and wait at least 15 minutes for internal capacitors to discharge before servicing the terminal connections.

Does the ATV12P075M3 include an internal cooling fan?

No, this model does not have a built-in fan and relies on natural convection cooling.

What communication protocol is built into this drive?

The drive features an integrated RJ45 port for Modbus serial communication.

What is the rated power of this drive?

The drive is rated for 0.75 kW (1 hp) operation.

Is this drive suitable for 3-phase power?

Yes, it is designed for a 200–240 V, 3-phase supply.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...