1 of 1

1056-01-21-31-AN | Rosemount | 1056 Dual Channel Transmitter

1056-01-21-31-AN | Rosemount | 1056 Dual Channel Transmitter

Only 10 item(s) left in stock
  • Manufacturer: Rosemount

  • Product No.: 1056-01-21-31-AN

  • Country of origin:Amerika Syarikat

  • Product Type: Transmitter

  • Payment: T/T, Western Union

  • Weight: 5000g

  • Dimensions: 15.5 cm x 15.5 cm x 13.1 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

The Rosemount 1056-01-21-31-AN is a sophisticated dual-channel multi-parameter transmitter designed for demanding liquid analysis. This specific configuration is optimized for Dual Toroidal Conductivity measurements, allowing for simultaneous monitoring of two separate process lines or the calculation of differential conductivity in high-concentration chemical applications.

Technical Specifications

Category Specification
Manufacturer Rosemount (Emerson)
Model 1056
Power Supply 115/230 VAC, 50/60 Hz (No Relays)
Measurement 1 Toroidal Conductivity
Measurement 2 Toroidal Conductivity
Output / Communication Dual 4-20 mA Analog Outputs
Operating Temperature 0 to 55 °C (32 to 131 °F)
Enclosure Rating NEMA 4X / IP66
Shipping Weight 5.0 kg

Measurement Capability

  • Toroidal (Inductive) Method: Ideal for high-conductivity liquids, slurries, or corrosive chemicals that would foul or coat standard contact electrodes.

  • Dual Display: The large, high-contrast LCD displays both measurements simultaneously with user-defined units.

  • Auto-Configuration: The transmitter automatically recognizes the measurement boards upon power-up.


Installation & Wiring Guidelines

  • Mounting Options: The 1056 is versatile and can be mounted via panel-mount (1/2 DIN), pipe-mount, or surface-mount. Ensure the rear cable glands are tightened to maintain the NEMA 4X seal.

  • Power Connection: This unit is configured for 01 (AC Power). Internal jumpers or terminal selection must be checked to match your local supply of 115 VAC or 230 VAC.

  • Sensor Compatibility: This model requires Toroidal sensors (e.g., Rosemount 222, 225, or 228 series). Ensure the sensor cable is properly shielded and routed away from high-power VFD or motor cables.

  • Analog Outputs: The dual 4-20 mA outputs are isolated. They can be mapped to represent Conductivity 1, Conductivity 2, or the temperature of either process.


Frequently Asked Questions (FAQs)

Why choose Toroidal conductivity over Contacting conductivity?

Toroidal sensors are "non-contacting." They use induction to measure conductivity, making them nearly maintenance-free in applications that involve heavy oils, fibrous slurries, or high-acid/base concentrations that would corrode standard sensors.

Does this model include alarm relays?

No. The "01" power option in this specific product code indicates "no relays." If your application requires local high/low alarm triggers, you must utilize the 4-20 mA signals to an external PLC or DCS, or select a different hardware configuration.

How do I calibrate the dual channels?

Calibration is performed through the front-panel membrane keypad. You can perform a "Zero" calibration in air and a "Standard" calibration using a solution of known conductivity or by comparing it to a grab sample.

Is the display visible in direct sunlight?

Yes, the 1056 features a high-contrast, black-on-white LCD that is designed for high visibility in both indoor industrial lighting and outdoor daylight conditions.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Putih
Country of origin
Amerika Syarikat

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Recently Viewed Products

Technical knowledge

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...

Persediaan Kawalan Gerakan Paksi Tunggal dengan Pemacu Servo CMZ

Tutorial ini meneroka penyediaan sistem gerakan servo paksi tunggal menggunakan pemacu CMZ SBD, merangkumi penyediaan perkakasan, penskalaan paksi, konfigurasi homing, dan pengesahan gerakan selamat...