1 daripada 3

ABB 61298487 ACS 600 DSU CONTROL NDSC-01

ABB 61298487 ACS 600 DSU CONTROL NDSC-01

Hanya 6 item tinggal dalam stok
  • Pengilang: ABB

  • No. Produk: NDSC-01 61298487

  • Negara asal:Sweden

  • Jenis Produk: DSU Control Board

  • Kod Bar: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 800g

  • Dimensi: 28 cm x 23.2 cm x 2.5 cm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

The ABB 61298487 is a dedicated DSU CONTROL NDSC-01 control board engineered for the ACS 600 frequency converter series. It serves as the primary hardware processing unit for Diode Supply Units (DSU) managing six-pulse and twelve-pulse half-controlled rectifier bridges. The device directly supervises high-ohmic AC line voltage sensing, DC busbar measurements, synchronization timing, and gate pulse generation for the power semiconductors. It integrates software logic to ensure seamless execution of charging modes and normal operational tracking within continuous current configurations.

Features

  • Complete control board layout integrating three galvanically isolated digital inputs and three relay outputs.
  • Onboard high-ohmic resistor chains supporting high-voltage tracking up to actual network levels without standard external scaling.
  • Dedicated DDCS communication link interfaces and localized diagnostic tracking via a 7-segment hardware display.
  • Configurable operational parameters utilizing twin 8-way integrated DIP switches for rapid configuration adjustments.

Applications

  • Half-controlled rectifier bridge tracking within continuous industrial DC link assemblies.
  • Multi-pulse system coordination for parallel diode supply modules.
  • Active phase synchronization oversight and system protection routines in industrial frequency converters.

Technical Specifications

Parameter Value
Manufacturer ABB 
Product ID 61298487
Product Name DSU CONTROL NDSC-01
Replacement Product ID (NEW) 64560930
Country of Origin Finland (FI)
Customs Tariff Number 85049099
Digital Inputs 3 channels (galvanically isolated, 10 ms time constant) 
Digital Input Voltage Range 24 VDC ... 230 VAC 
Digital Outputs 3 + 1 relay outputs (1500 VAC channel test voltage) 
Auxiliary Output Supply +24 VDC (500 mA, fuse protected) 
Net Weight 0.8 kg
Gross Weight 0.8 kg

Connections/Interfaces

Connector Pin Function
X1 Pins 1 and 2 Connection interface for an optional current transformer with a 400/1 A ratio 
X1 Pins 1 and 3 Alternative 24 VDC auxiliary digital input for earth fault indicator tracking 
X2 Pins 1, 2 Digital Input 1 (DI1) connection terminal 
X2 Pins 3, 4 Digital Input 2 (DI2) connection terminal 
X2 Pins 5, 6 Digital Input 3 (DI3) connection terminal 
X3 Terminal +24 VDC fuse-protected auxiliary power output connection 
X4 Pins 1, 2 Relay Digital Output 1 (DO1) connection terminal 
X4 Pins 3, 4 Relay Digital Output 2 (DO2) connection terminal 
X4 Pins 5, 6 Relay Digital Output 3 (DO3) connection terminal 
TXD / RXD DDCS fiber optic communication links for overriding systems 

Installation Guidelines

  • Isolate all electrical source networks before commencing mounting or terminal connection routines.
  • Fasten the card assembly inside the chassis envelope using original metallic mounting supports to establish functional ground contacts.
  • Set the target configuration criteria matching application specifications via the 8-way integrated DIP switches before operational initialization.
  • Route internal wiring clear of raw high-voltage power paths to lower EMI coupling risks across the 10 ms low-pass terminal filters.
Loading product navigation…
Key Features:

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB 61298487 ACS 600 DSU CONTROL NDSC-01

What is the voltage range supported by the digital inputs on the module?

The digital inputs are self-adaptive and support an operating voltage range from 24 VDC up to 230 VAC.

What happens if an earth fault is identified by the device?

If an earth fault current exceeds the software limit, the device executes a protective trip loop and lists code F05 on the 7-segment display.

Are the actual main circuit voltage signals on the board isolated?

No, the main circuit actual voltage monitoring loops for lines U1, V1, W1, Uc1, and Uc2 are not galvanically isolated.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Color pattern
Hijau
Country of origin
Sweden
Power source
Dikuasakan oleh AC

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...